Page 1 of 2 7" Aperture, ED17 (Open Rated) Ceramic Metal Halide, Wide Beam
20" (508 mm) to 30" (762 mm) 9-3/4" (248 mm)
5 4 9 10 7
3 1 6 8
Top View (Magnetic Ballast)
20" (508 mm) to 30" (762 mm)
11" (280 mm) (100/150W)
Top View (Electronic Ballast)
2" (50 mm) max. Ceiling Thickness 7-3/8" (187 mm) Dia.
Ceiling Cutout: 8" (203 mm) Dia.
8-5/8" (200 mm) Dia.
C7E170VW CLW Specular Clear, White Painted Flange. C770MHOE1 Electronic 120V / C770MHOE2 Electronic 277V 70W E17, ED17, BD17 (Open Rated) CLP Specular Clear, Matching Flange. C710MHOE1 Electronic 120V / C710MHOE2 Electronic 277V 100W E17, ED17, BD17 (Open Rated) CCDW Comfort Clear Diffuse, White Painted Flange. C715MHOE1 Electronic 120V / C715MHOE2 Electronic 277V 150W E17, ED17, BD17 (Open Rated) CCDP Comfort Clear Diffuse, Matching Flange. C770MHOU Magnetic 120V/277V 70W E17, ED17, BD17 (Open Rated) CCZW Champagne Bronze, White Painted Flange. C710MHOU Magnetic 120V/277V 100W E17, ED17, BD17 (Open Rated) CCZP Champagne Bronze, Matching Flange. C715MHOU Magnetic 120V/277V 150W E17, ED17, BD17 (Open Rated)
Features 1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide beam distribution. 2. Aperture Cone: Provides 50° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes. 3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated socket. Snaps onto upper reflector for secure attachment without tools; uni- tized construction assures proper lamp alignment to optics for consistent performance. 4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical adjustment from above or below. For ceiling from 0" to 2" thick. Center line notches allow consistent alignment of multiple fixtures. 5. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed mounting bars. 6. Aperture Cone Retention Springs: Rust resistant springs secure cone in place for quick, tool-less installation. 7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. 8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies instal- lation in 24" O.C. grid systems. Attaches to steel or wood joists without acces- sories. 9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools. 10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below. 11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.
Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M139 120/277 0.67/0.29 78 100W MH M90/M140 120/277 0.90/0.43 110 150MH M102 120/277 1.40/0.61 167 Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating "B", -20°F minimum starting temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125 150MH M102 120/277 3.70/1.60 180 Options and Accessories Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec. Sheet "A/E" Emergency Lamp: Add suffix E to Frame-In Kit and Reflector Trim. See Spec. Sheet "A/E" Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V) Chicago Plenum: Consult Factory.
Labels UL (Suitable for Damp Locations), CSA, I.B.E.W. For 150W, install fixtures with minimum spacing: 3 feet from center-to-center of adjacent luminaries; 3 inch from
top of luminaire to overhead building member;1 1/2 feet from luminaire center to side building member.
Job Name:
Cat. No.:
Lamp(s):
Electrical Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor, T.H.D.

Page 2 of 2 7" Aperture, ED17 (Open Rated) Ceramic Metal Halide Wide Beam
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 33868 55 713 65 157 75 0 85 0
0 .70 .69 .69 .66 .66 .63 .63 .59 1 .67 .65 .64 .63 .64 .62 .62 .60 .60 .58 .55 2 .64 .61 .59 .57 .60 .56 .58 .55 .57 .54 .52 3 .61 .57 .54 .52 .56 .52 .55 .51 .53 .50 .48 4 .58 .53 .50 .48 .53 .47 .52 .47 .50 .46 .45 5 .55 .50 .46 .44 .49 .44 .48 .43 .47 .43 .42 6 .52 .47 .43 .41 .46 .40 .45 .40 .44 .40 .39 7 .49 .43 .40 .37 .43 .37 .42 .37 .41 .36 .35 8 .46 .40 .36 .34 .39 .34 .39 .34 .38 .33 .32 9 .43 .37 .33 .31 .37 .31 .36 .31 .36 .30 .29 10 .40 .34 .30 .28 .34 .28 .33 .28 .33 .28 .27 LUMINAIRE INPUT WATTS = 78.0
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 1765 30.97 52.49 0-40 2834 49.73 84.27 0-60 3361 58.97 99.93 0-90 3363 59.01 100 40-90 529 9.28 15.73 60-90 2 0.04 0.07 90-180-180 3363 59.01 100
** EFFICIENCY = 59.0% ** CERTIFIED TEST REPORT NO. 2373FR, DATE: FEB 10, 2004 SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 52847 55 607 65 0 75 0 85 0
0 .70 .68 .68 .65 .65 .62 .62 .59 1 .67 .65 .64 .62 .64 .61 .61 .59 .59 .58 .55 2 .63 .61 .59 .57 .60 .56 .58 .55 .56 .54 .52 3 .60 .57 .54 .52 .56 .51 .54 .50 .53 .50 .48 4 .57 .53 .50 .47 .52 .47 .51 .47 .50 .46 .45 5 .54 .49 .46 .43 .49 .43 .48 .43 .47 .43 .41 6 .51 .46 .43 .40 .46 .40 .45 .40 .44 .39 .38 7 .48 .43 .39 .37 .42 .36 .42 .36 .41 .36 .35 8 .45 .40 .36 .34 .39 .33 .39 .33 .38 .33 .32 9 .43 .37 .33 .30 .36 .30 .36 .30 .35 .30 .29 10 .40 .34 .30 .28 .33 .28 .33 .28 .33 .27 .27 LUMINAIRE INPUT WATTS = 110
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 2607 30.68 52.39 0-40 4171 49.08 83.81 0-60 4977 58.56 99.99 0-90 4977 58.56 100 40-90 805 9.48 16.19 60-90.01 90-180-180 4977 58.56 100
** EFFICIENCY = 58.6% ** CERTIFIED TEST REPORT NO. 2374FR, DATE: FEB 10, 2004 SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M 45 76396 55 1479 65 193 75 0 85 0
0 .71 .69 .69 .66 .66 .64 .64 .60 1 .68 .66 .65 .63 .65 .62 .62 .61 .60 .59 .56 2 .65 .62 .60 .58 .61 .57 .59 .56 .57 .55 .52 3 .61 .58 .55 .52 .57 .52 .55 .51 .54 .50 .49 4 .58 .54 .51 .48 .53 .48 .52 .47 .51 .47 .45 5 .55 .50 .47 .44 .50 .44 .48 .44 .48 .43 .42 6 .52 .47 .43 .41 .46 .40 .45 .40 .45 .40 .39 7 .49 .43 .40 .37 .43 .37 .42 .37 .41 .37 .36 8 .46 .40 .36 .34 .40 .34 .39 .34 .39 .33 .32 9 .43 .37 .33 .31 .37 .31 .36 .31 .36 .30 .29 10 .40 .34 .30 .28 .34 .28 .33 .28 .33 .28 .27 LUMINAIRE INPUT WATTS = 167
ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 3668 30.83 51.63 0-40 5925 49.79 83.4 0-60 7101 59.68 99.95 0-90 7104 59.7 100 40-90 1179 9.91 16.6 60-90 3 0.03 0.05 90-180-180 7104 59.7 100
** EFFICIENCY = 59.7% ** CERTIFIED TEST REPORT NO. 2375FR, DATE: FEB 10, 2004 SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**