Calculite ® HID Downlight C7E170VW

Page 1 of 2 7" Aperture, ED17 (Open Rated) Ceramic Metal Halide, Wide Beam

20" (508 mm) to 30" (762 mm) 9-3/4" (248 mm)

5 4 9 10 7

3 1 6 8

Top View (Magnetic Ballast)

20" (508 mm) to 30" (762 mm)

Vertical Adjustment5/8" (16 mm) to 2 7/8" (73 mm)

11" (280 mm) (100/150W)

Top View (Electronic Ballast)

2" (50 mm) max. Ceiling Thickness 7-3/8" (187 mm) Dia.

Ceiling Cutout: 8" (203 mm) Dia.

8-5/8" (200 mm) Dia.

Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH)

C7E170VW CLW Specular Clear, White Painted Flange. C770MHOE1 Electronic 120V / C770MHOE2 Electronic 277V 70W E17, ED17, BD17 (Open Rated) CLP Specular Clear, Matching Flange. C710MHOE1 Electronic 120V / C710MHOE2 Electronic 277V 100W E17, ED17, BD17 (Open Rated) CCDW Comfort Clear Diffuse, White Painted Flange. C715MHOE1 Electronic 120V / C715MHOE2 Electronic 277V 150W E17, ED17, BD17 (Open Rated) CCDP Comfort Clear Diffuse, Matching Flange. C770MHOU Magnetic 120V/277V 70W E17, ED17, BD17 (Open Rated) CCZW Champagne Bronze, White Painted Flange. C710MHOU Magnetic 120V/277V 100W E17, ED17, BD17 (Open Rated) CCZP Champagne Bronze, Matching Flange. C715MHOU Magnetic 120V/277V 150W E17, ED17, BD17 (Open Rated)

Features 1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide beam distribution. 2. Aperture Cone: Provides 50° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes. 3. Socket Cup: Galvanized steel, pre-wired with medium base pulse rated socket. Snaps onto upper reflector for secure attachment without tools; uni- tized construction assures proper lamp alignment to optics for consistent performance. 4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical adjustment from above or below. For ceiling from 0" to 2" thick. Center line notches allow consistent alignment of multiple fixtures. 5. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed mounting bars. 6. Aperture Cone Retention Springs: Rust resistant springs secure cone in place for quick, tool-less installation. 7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. 8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies instal- lation in 24" O.C. grid systems. Attaches to steel or wood joists without acces- sories. 9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools. 10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below. 11.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.

Electrical (cont.)

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M139 120/277 0.67/0.29 78 100W MH M90/M140 120/277 0.90/0.43 110 150MH M102 120/277 1.40/0.61 167 Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating "B", -20°F minimum starting temperature, Type 1 Outdoor rating.

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125 150MH M102 120/277 3.70/1.60 180 Options and Accessories Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec. Sheet "A/E" Emergency Lamp: Add suffix E to Frame-In Kit and Reflector Trim. See Spec. Sheet "A/E" Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 or F2 to Frame-In Kit (F1=120V, F2=277V) Chicago Plenum: Consult Factory.

Labels UL (Suitable for Damp Locations), CSA, I.B.E.W. For 150W, install fixtures with minimum spacing: 3 feet from center-to-center of adjacent luminaries; 3 inch from

top of luminaire to overhead building member;1 1/2 feet from luminaire center to side building member.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Electrical Electronic Ballast: 120 or 277V, 50/60 Hz., encased, high power factor, T.H.D.

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Show 7 more labels / short text on this page
8-1/4" (210 mm) · 10-1/2" (267 mm) · 18-5/8" (473 mm) · 10-7/8" (276 mm) · 11-7/8" (301 mm) · 9-3/4" (248 mm) · 10-7/8" (276 mm)
Page 2 of the Lightolier C7E170VW user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® HID Downlight C7E170VW

Page 2 of 2 7" Aperture, ED17 (Open Rated) Ceramic Metal Halide Wide Beam

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 33868 55 713 65 157 75 0 85 0

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .70 .69 .69 .66 .66 .63 .63 .59 1 .67 .65 .64 .63 .64 .62 .62 .60 .60 .58 .55 2 .64 .61 .59 .57 .60 .56 .58 .55 .57 .54 .52 3 .61 .57 .54 .52 .56 .52 .55 .51 .53 .50 .48 4 .58 .53 .50 .48 .53 .47 .52 .47 .50 .46 .45 5 .55 .50 .46 .44 .49 .44 .48 .43 .47 .43 .42 6 .52 .47 .43 .41 .46 .40 .45 .40 .44 .40 .39 7 .49 .43 .40 .37 .43 .37 .42 .37 .41 .36 .35 8 .46 .40 .36 .34 .39 .34 .39 .34 .38 .33 .32 9 .43 .37 .33 .31 .37 .31 .36 .31 .36 .30 .29 10 .40 .34 .30 .28 .34 .28 .33 .28 .33 .28 .27 LUMINAIRE INPUT WATTS = 78.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 1765 30.97 52.49 0-40 2834 49.73 84.27 0-60 3361 58.97 99.93 0-90 3363 59.01 100 40-90 529 9.28 15.73 60-90 2 0.04 0.07 90-180-180 3363 59.01 100

** EFFICIENCY = 59.0% ** CERTIFIED TEST REPORT NO. 2373FR, DATE: FEB 10, 2004 SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE MEAN CD/SQ M 45 52847 55 607 65 0 75 0 85 0

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .70 .68 .68 .65 .65 .62 .62 .59 1 .67 .65 .64 .62 .64 .61 .61 .59 .59 .58 .55 2 .63 .61 .59 .57 .60 .56 .58 .55 .56 .54 .52 3 .60 .57 .54 .52 .56 .51 .54 .50 .53 .50 .48 4 .57 .53 .50 .47 .52 .47 .51 .47 .50 .46 .45 5 .54 .49 .46 .43 .49 .43 .48 .43 .47 .43 .41 6 .51 .46 .43 .40 .46 .40 .45 .40 .44 .39 .38 7 .48 .43 .39 .37 .42 .36 .42 .36 .41 .36 .35 8 .45 .40 .36 .34 .39 .33 .39 .33 .38 .33 .32 9 .43 .37 .33 .30 .36 .30 .36 .30 .35 .30 .29 10 .40 .34 .30 .28 .33 .28 .33 .28 .33 .27 .27 LUMINAIRE INPUT WATTS = 110

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 2607 30.68 52.39 0-40 4171 49.08 83.81 0-60 4977 58.56 99.99 0-90 4977 58.56 100 40-90 805 9.48 16.19 60-90.01 90-180-180 4977 58.56 100

** EFFICIENCY = 58.6% ** CERTIFIED TEST REPORT NO. 2374FR, DATE: FEB 10, 2004 SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**

LUMINANCE SUMMARY - CD. / SQ. M.

ANGLE MEAN CD/SQ M 45 76396 55 1479 65 193 75 0 85 0

Coefficients of Utilization

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .71 .69 .69 .66 .66 .64 .64 .60 1 .68 .66 .65 .63 .65 .62 .62 .61 .60 .59 .56 2 .65 .62 .60 .58 .61 .57 .59 .56 .57 .55 .52 3 .61 .58 .55 .52 .57 .52 .55 .51 .54 .50 .49 4 .58 .54 .51 .48 .53 .48 .52 .47 .51 .47 .45 5 .55 .50 .47 .44 .50 .44 .48 .44 .48 .43 .42 6 .52 .47 .43 .41 .46 .40 .45 .40 .45 .40 .39 7 .49 .43 .40 .37 .43 .37 .42 .37 .41 .37 .36 8 .46 .40 .36 .34 .40 .34 .39 .34 .39 .33 .32 9 .43 .37 .33 .31 .37 .31 .36 .31 .36 .30 .29 10 .40 .34 .30 .28 .34 .28 .33 .28 .33 .28 .27 LUMINAIRE INPUT WATTS = 167

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 3668 30.83 51.63 0-40 5925 49.79 83.4 0-60 7101 59.68 99.95 0-90 7104 59.7 100 40-90 1179 9.91 16.6 60-90 3 0.03 0.05 90-180-180 7104 59.7 100

** EFFICIENCY = 59.7% ** CERTIFIED TEST REPORT NO. 2375FR, DATE: FEB 10, 2004 SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Show 16 more labels / short text on this page
60° · 1,250 · 1,875 · 2,500 · 30° · 60° · 1,750 · 2, 625 · 3,500 · 30° · 1,250 · 60° · 2,500 · 3,750 · 5,000 · 30°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C7E170VWについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C7E170VWに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C7E170VW 取扱説明書(PDF)

2 ページ·109 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…