JA
Lightolier logo
公式取扱説明書

Lightolier C7E17HW

2 ページ·195 KB·インテリア家具・調度品·PDF·EN
Lightolier C7E17HW
目次 8セクション Calculite ® HID Downlight C7E17HW · Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH) · Job Information Type: · Coefficients of Utilization · … 表示非表示
Page 1 of the Lightolier C7E17HW user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Calculite ® HID Downlight C7E17HW

Page 1 of 2 7" Aperture, ED17 (Enclosed) Ceramic Metal Halide, Wide Beam

Ceiling Cutout: 8” (203 mm) Dia.

Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH)

C7E17HW CLW Specular Clear White Painted Flange. CLP Specular Clear Matching Flange. CCDW Comfort Clear Diffuse, White Painted Flange. CCDP Comfort Clear Diffuse, Matching Flange. CCZW Champagne Bronze, White Painted Flange. CCZP Champagne Bronze, Matching Flange.

C770MHE1 Electronic 120V 70W ED17, BD17 (Enclosed) C770MHE2 Electronic 277V 70W ED17, BD17 (Enclosed) C710MHE1 Electronic 120V 100W ED17, BD17 (Enclosed) C710MHE2 Electronic 277V 100W ED17, BD17 (Enclosed) C770MHU Magnetic 120V/277V 70W ED17, BD17 (Enclosed) C710MHU Magnetic 120V/277V 100W ED17, BD17 (Enclosed)

Features 1. Reflector Trim: Clear anodized aluminum, 0.040” (16-ga.). Provides Wide beam distribution; 50° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes. 2. Lamp Guard: High heat resistant glass (as required by code). 3. Socket Cup: Galvanized steel. Pre-wired with medium base pulse rated socket. Snaps onto upper reflector for secure attachment without tools; assures proper lamp alignment to optics for consistent performance. 4. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed mounting bars. 5. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures. 6. Retention Springs: Rust resistant springs secure cone in place for quick, tool-less installation. 7. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. 8. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 9. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools. 10.Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below.

Electrical (cont.) Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF circuit type, high power factor, sound rating “B”, -20°F minimum starting temperature, Type 1 Outdoor rating.

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125

Options and Accessories Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“. Emergency : Add suffix E to Reflector Trim and Frame-In Kit. See Spec.Sheet “E”. Slope Ceiling Adapters: See Specification Sheet SCA. Fuse (magnetic ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V) Chicago Plenum: Consult Factory

Labels UL (Suitable for Damp Locations), CSA, (magnetic ballast only). I.B.E.W. For 100W, install fixtures with minimum spacing: 2 feet from center-to-center of adjacent luminaries; 1/2 inch from top of luminaire to overhead building member; 1 foot from luminaire center to side building member.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Electrical Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M198/M143 120/277 0.67/0.28 78 100W MH M90/M140 120/277 0.90/0.43 110

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Page 2 of the Lightolier C7E17HW user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® HID Downlight C7E17HW

Page 2 of 2 7" Aperture, ED17 (Enclosed) Ceramic Metal Halide, Wide Beam

70W ED17 (ENCLOSED) PHILIPS COATED MH LAMP. LUMEN RATING = 6000 LMS., ELECTRONIC AROMAT BALLAST, CL FINISH REFLECTOR

ANGLE 0° 45° 90° 0 3661 3661 3661 5 3538 3625 3689 10 3352 3507 3664 15 3017 3262 3524 20 2666 2901 3192 25 2310 2392 2677 30 1684 1780 2031 35 1099 1210 1512 40 704 784 937 45 263 295 316 50 29 34 31 55 5 4 6 60 65 0 0 0 70 75 0 0 0 80 85 0 0 0 90

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE 0° 45° 90° 45 13056 14682 15733 55 276 215 339 65 0 0 0 75 0 0 0 85 0 0 0

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .69 .67 .67 .64 .64 .61 .61 .58 1 .66 .65 .63 .62 .63 .61 .61 .59 .59 .58 .55 2 .63 .61 .59 .57 .60 .57 .58 .55 .56 .54 .52 3 .61 .58 .55 .53 .57 .53 .55 .52 .54 .51 .50 4 .58 .55 .52 .50 .54 .49 .53 .49 .52 .48 .47 5 .56 .52 .49 .47 .51 .46 .50 .46 .49 .46 .44 6 .53 .49 .46 .44 .49 .44 .48 .43 .47 .43 .42 7 .51 .46 .43 .41 .46 .41 .45 .41 .44 .40 .40 8 .49 .44 .41 .39 .43 .38 .43 .38 .42 .38 .37 9 .46 .41 .38 .36 .41 .36 .40 .36 .40 .36 .35 10 .44 .39 .36 .34 .39 .34 .38 .34 .38 .34 .33

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 2370 39.51 68.49 0-40 3175 52.93 91.77 0-60 3460 57.68 100 0-90 3460 57.68 100 40-90 284 4.75 8.23 60-90 90-180-180 3460 57.68 100

LUMINAIRE INPUT WATTS = 78.0

** EFFICIENCY = 57.7% ** CERTIFIED TEST REPORT NO. 2621FR, DATE: MAY 20, 2004 SC(ALONG) =.9 COMPUTED BY LSI PROGRAM **TEST-LITE** SC(ACROSS) =1.0

100W ED17 (ENCLOSED) PHILIPS COATED MH LAMP. LUMEN RATING = 9000 LMS., ELECTRONIC AROMAT BALLAST, CL REFLECTOR TRIM

ANGLE0° 45° 90° 0 5488 5488 5488 5 5304 5434 5530 10 5025 5258 5493 15 4523 4890 5284 20 3996 4349 4786 25 3461 3586 4013 30 2524 2667 3044 35 1646 1812 2265 40 1052 1173 1403 45 392 439 471 50 41 47 44 55 4 4 5 60 65 0 0 0 70 75 0 0 0 80 85 0 0 0 90

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE 0° 45° 90° 45 19435 21873 23449 55 230 231 323 65 0 0 0 75 0 0 0 85 0 0 0

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method -Effective Floor Cavity Reflectance = 20%

RCR

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 3553 39.48 68.56 0-40 4759 52.88 91.84 0-60 5182 57.59 100 0-90 5182 57.59 100 40-90 423 4.7 8.16 60-90 90-180-180 5182 57.59 100

LUMINAIRE INPUT WATTS = 110

** EFFICIENCY = 57.6% ** CERTIFIED TEST REPORT NO. 2630FR, DATE: MAY 23, 2004 SC(ALONG) = .9 COMPUTED BY LSI PROGRAM **TEST-LITE** SC(ACROSS) = 1.0

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Show 11 more labels / short text on this page
60° · 1,750 · 2,625 · 3,500 · 30° · 1,375 · 60° · 2,750 · 4,125 · 5,500 · 30°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier C7E17HWについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier C7E17HWに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier C7E17HW 取扱説明書(PDF)

2 ページ·195 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…