1BHFPG 2 $FOUSBM5SPVHI3FDFTTFE%JSFDU-PVWFS-JHIU51FS'PPU4FDUJPO

Complete ordering instructions on back.
Features 1. Housing: Die-formed steel, slotted for air return. Integral flanges at each end strengthen the housing and permit housings to be bolted together in continuous runs and facilitate suspension of fixture. Concealed openings for heat extraction and air return. 2. Lamping: One or two T8 or T12 fluorescent lamps, as specified. Provided by others. 3. Reflector: Die-formed prepainted white. 4. Louver: Semi-specular anodized aluminum, 40° lengthwise by 30° minimum crosswise shielding. Supported along both edges by concealed frame of extruded aluminum. Bold baffle, prismatic lens, gold anodized louver, open or egg crate louver available, consult factory. 5. Ceiling Trim: Extruded aluminum alloy with integral aligner splines and con- toured for brightness control. 6. Electrical Chassis: Mounted into housing and secured by brackets and steel spring clips. Grounding and locking latches join chassis in continuous runs. Fluorescent lamps overlap 3" (7.62cm) to eliminate shadows.
Electrical Specify 120 volt or 277 volt. 3 conductor, 18 gauge wire. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting, consult factory. Rapid start, HPF, class "P" thermally protected. PowerSpec HDF dimming ballast is available.
Mountings Electrical housing is mounted without the removal of any screws, nuts or hardware. Housing is suspended by hanger wires.
Finish Ceiling trim painted baked enamel semi-gloss white.
Options and Accessories 90 degree universal corner.
Labels UL, cUL and I.B.E.W.
Example of Straight Run

21' 10" (665.48cm)

"JSQPSU3PBE 'BMM3JWFS ."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

1BHFPG 2 $FOUSBM5SPVHI3FDFTTFE%JSFDU-PVWFS-JHIU51FS'PPU4FDUJPO
Performance & Quick Calculators
CANDLEPOWER SUMMARY
COEFFIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE
180˚ 175˚ 165˚ 155˚ 145˚ 135˚
Deg 180 175 0 165 0 155 0 145 0 135 0 125 0 115 0 105 0 95 0 85 1 2 4 6 7 75 9 11 16 22 27 65 27 34 52 89 99 55 134 206 223 246 239 45 361 456 460 442 442 35 511 572 639 666 589 25 614 644 702 765 785 15 692 702 725 756 759 5 723 722 729 727 728 0 730
ZONE LUMENS % BARELAMP %LUMINAIRE
0-901 597 50.7 100.00 90-180 0 0.0 0.0 0-180 1597 50.7 100.00
0˚ 5˚ 15˚ 25˚ 35˚ 45˚
ROOM SURFACE REFLECTANCES 80% CEILING 50% WALLS 20% FLOOR
3200 LUMENS PER LAMP RCR - 1(Rm width - 10xMtg Ht above work plane) RCR - 5 (Rm width - 2xMtg Ht above work plane) RCR - 10 (Rm width - Mtg Ht above work plane)
4 6 8 10 12 14 16
CENTER TO CENTER SPACING OF FIXTURE ROWS IN FEET
FOR 2 LIGHT UNITS MULTIPLY CHART VALUES BY 2.0
Two Lamps
*Each run MUST include a Telescoping fixture as the CD12 end plates only ship as part of the Telescoping fixture.
Blank = T12 Magnetic 120V 2 = T12 Magnetic 277V E1 = T12 Electronic 120V E2 = T12 Electronic 277V E81 = T8 Electronic 120V E82 = T8 Electronic 277V M71 = T8 Electronic Dimming Ballast 120V M72 = T8 Electronic Dimming Ballast 277V HD1 = T8 PowerSpec® HDF Dimming 120V HD2 = T8 PowerSpec® HDF Dimming 277V
Continuous Rows: 1. Determine run length. 2. Determine lamp configuration (1 or 2 lamp). 3. Use Ordering Information Chart to find catalog numbers. A. Each run ends with a TELESCOPING UNIT. B. Starting with the longest MODULAR UNIT, fill in the remaining run.
"JSQPSU3PBE 'BMM3JWFS ."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #