Page 1 of 2 Direct/Indirect Surface Mounted Fluorescent – 2' x 4' with Perforated Basket


Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
11/08

Page 2 of 2 Direct/Indirect Surface Mounted Fluorescent– 2' x 4' with Perforated Basket
Model No. CDB2SPF228UNVPG LER = FP - 33.2 IW - 122.1 BF - 1.0 Comparative yearly lighting energy cost per
Model No. CDB2SPF254UNVPG LER = FP - 54.6 IW - 121.6 BF - 1.0 Comparative yearly lighting energy cost per
CANDELA DISTRIBUTION
1000 lumens = $7.29
1000 lumens = $4.40


Report Number: G2007118A Catalog Number: CDB2SPF228UNVPG Lamps: (2) F28T5 Luminaire: Coffaire Drop Basket Ballast: B228PUNV-D Report is based on 2900 Lumens per lamp. Efficiency: 69.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400
Report Number: G2007117A Catalog Number: CDB2SPF254UNVPG Lamps: (2) F54T5HO Luminaire: Coffaire Drop Basket Ballast: B254PUNV-D (Universal) Report is based on 5000 Lumens per lamp. Efficiency: 66.4% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400
0 1225 1225 1225
0 2020 2020 2020
5 1217 1219 1222 116
5 2007 2008 2012 191
15 1159 1174 1190 332
15 1913 1934 1960 547
25 1055 1093 1134 504
25 1737 1799 1865 830
35 907 982 1055 615
35 1494 1616 1735 1011
45 728 854 956 655
45 1196 1402 1572 1076
55 526 717 850 630
55 860 1176 1394 1033
65 326 588 728 554
65 532 960 1188 905
75 163 447 563 431
75 264 724 903 698
85 39 219 309 220
85 60 349 490 348
90 5 71 142
90 7 113 222
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 952 16.4 23.5 00-040 1567 27.0 38.6 00-060 2852 49.2 70.3 00-090 4057 69.9 100.0 90-180 0000 0.0 000.0 00-180 4057 69.9 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 1568 15.7 23.6 00-040 2579 25.8 38.9 00-060 4687 46.9 70.6 00-090 6639 66.4 100.0 90-180 0000 0.0 000.0 00-180 6639 66.4 100.0
01 75 71 67 66 63 61 63 61 59 02 67 61 55 57 52 49 54 51 48 03 61 53 46 49 44 40 47 43 39 04 55 46 40 44 38 34 42 37 33 05 51 41 34 39 33 29 37 32 29 06 47 37 30 35 29 25 34 29 25 07 43 33 27 32 26 22 31 26 22 08 40 30 24 29 24 20 28 23 20 09 38 28 22 27 21 18 26 21 18 10 35 26 20 25 20 16 24 19 16
01 71 67 64 63 60 58 60 58 56 02 64 58 52 54 50 46 52 48 45 03 58 50 44 47 42 38 45 41 38 04 53 44 38 41 36 32 40 35 32 05 48 39 33 37 32 28 36 31 27 06 45 35 29 33 28 24 32 27 24 07 41 32 26 30 25 21 29 25 21 08 38 29 23 28 23 19 27 22 19 09 36 27 21 25 20 17 25 20 17 10 34 25 19 23 19 15 23 18 15
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 956. 958. 935. 55 747. 838. 844. 65 521. 741. 758. 75 308. 623. 636. 85 94. 365. 394.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2222. 2539. 2776. 55 1929. 2544. 2913. 65 1564. 2681. 3158. 75 1179. 2978. 3442. 85 594. 2890. 3485.
CD
B
S
P
F
Body Style:
Ceiling Type:
Lamp Quantity 1=1 Lamp 2=2 Lamp 3=3 Lamp Ballast Type:
††Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only)
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.
Specifications (continued) Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: C. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 758 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 76.5%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.