Page 1 of 2 Direct/Indirect Surface Mounted Fluorescent – 2' x 4' with Perforated Basket
Features


Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
11/08

Page 2 of 2 Direct/Indirect Surface Mounted Fluorescent – 2' x 4' with Perforated Basket
Model No. CDB2SPF232UNVHI LER = FP - 64.7 IW - 50.4 BF - 0.88 Comparative yearly lighting energy cost per
Model No. CDB2SPF332UNVH3 LER = FP - 38.9 IW - 122.0 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $3.71
1000 lumens = $6.17


Report Number: G2007114A Catalog Number: CDB2SPF232UNVHI Lamps: (2) F28T8 Luminaire: Coffaire Drop Basket Ballast: QTP2X32T8/UNV ISN SC Report is based on 2725 Lumens per lamp. Efficiency: 68.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400
Report Number: G2007116A Catalog Number: CDB2SPF332UNVH3 Lamps: (3) F28T8 Luminaire: Coffaire Drop Basket Ballast: QTP3X32T8/UNV ISN SC Report is based on 2725 Lumens per lamp. Efficiency: 66.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400
0 1128 1128 1128
0 1706 1706 1706
5 1121 1122 1124 107
5 1695 1696 1698 161
15 1068 1081 1094 305
15 1612 1628 1648 460
25 970 1005 1041 463
25 1460 1508 1559 696
35 834 902 968 565
35 1253 1345 1435 842
45 668 784 878 601
45 999 1155 1284 886
55 481 658 776 576
55 716 952 1113 837
65 297 532 657 502
65 435 755 925 715
75 149 400 505 388
75 215 551 687 535
85 36 203 283 200
85 50 267 375 267
90 5 65 125
90 7 83 165
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 876 16.1 23.6 00-040 1440 26.4 38.8 00-060 2618 48.0 70.6 00-090 3708 68.0 100.0 90-180 0000 0.0 000.0 00-180 3708 68.0 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 1317 16.1 24.4 00-040 2159 26.4 40.0 00-060 3883 47.5 71.9 00-090 5399 66.0 100.0 90-180 0000 0.0 000.0 00-180 5399 66.0 100.0
01 72 69 65 64 61 59 61 59 57 02 65 59 54 55 51 47 53 49 46 03 59 51 45 48 43 39 46 42 38 04 54 45 39 42 37 33 41 36 32 05 50 40 34 38 32 28 36 32 28 06 46 36 30 34 29 25 33 28 24 07 42 33 26 31 26 22 30 25 22 08 39 30 24 28 23 19 27 23 19 09 37 27 21 26 21 17 25 21 17 10 34 25 20 24 19 16 23 19 16
01 71 67 64 63 60 58 60 58 56 02 64 58 53 54 50 47 52 48 46 03 58 50 44 47 42 39 45 41 38 04 53 44 38 42 37 33 40 36 32 05 48 39 33 37 32 28 36 31 28 06 45 35 29 34 28 24 32 28 24 07 41 32 26 30 25 22 29 25 21 08 39 29 23 28 23 19 27 22 19 09 36 27 21 26 21 17 25 20 17 10 34 25 19 24 19 16 23 19 16
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1241. 1420. 1550. 55 1079. 1424. 1622. 65 873. 1486. 1747. 75 665. 1645. 1925. 85 357. 1681. 2013.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1856. 2091. 2267. 55 1606. 2060. 2326. 65 1279. 2108. 2459. 75 960. 2266. 2618. 85 495. 2211. 2667.
CD
B
S
P
F
Body Style:
Ceiling Type:
Lamp Quantity 1=1 Lamp 2=2 Lamp 3=3 Lamp Ballast Type:
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.
Specifications (continued) Finish: Chassis exterior – Soft white post painted polyester powder. Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: C. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .69. To reduce glare the average brightness at 65° shall not exceed 1747 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 76.4%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.