Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Static, 2 Lamp T5




Exposed T-bar by others
Exposed T-bar by o hers
1-1/2" max.
Acoustical material by o hers
1-7/8" max.
Acoustical material by others
* For flush mounting when using 9/16" Exposed T-Grid ceiling system consult factory
exposed slot t-grid ceiling

T-bar by o hers
The fixture affixes to the outside of a ceiling's t bar and will not detach acting like an earthquake clip

T-bar by o hers
Job Name:
Lamp shield hinges either side
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Static, 2 Lamp T5
Model No. CDS2GPF214UNVPG LER = FP - 54.2 IW - 33.2 BF - 1.06 Comparative yearly lighting ene gy cost per
Model No. CDS2GPF224UNVPG LER = FP - 48.5 IW - 51.7 BF - 1.0 Comparative yearly lighting ene gy cost per
CANDELA DISTRIBUTION
1000 lumens = $4.43
1000 lumens = $4.95


Report Number: G2007134 Catalog Number: CDS2GPF214UNVPG Lamps: (2) F14T5 Luminaire: Coffaire Drop Basket Ballast: INC-2S28 Report is based on 1350 Lumens per lamp. Efficiency: 62.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
Report Number: G2007135 Catalog Number: CDS2GPF224UNVPG Lamps: (2) F24T5 Luminaire: Coffaire Drop Basket Ballast: B224PUNV-C Report is based on 2000 Lumens per lamp. Efficiency: 62.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
0 523 523 523
0 777 777 777
5 520 520 521 49
5 773 773 775 74
15 494 500 507 141
15 733 743 754 210
25 447 464 483 214
25 663 689 717 318
35 383 416 448 260
35 567 616 666 386
45 306 359 405 276
45 453 532 602 409
55 220 298 359 263
55 324 441 532 389
65 136 239 305 228
65 200 352 450 336
75 71 178 241 176
75 104 260 352 256
85 18 91 134 90
85 24 131 191 128
90 2 32 62
90 3 45 89
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL LUMEN SUMMARY
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 405 15 0 23 9 0- 40 666 24 7 39 2 0- 60 1205 44 6 70 9 0- 90 1698 62 9 100 0 90-180-180 1698 62 9 100 0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 602 15 0 24.0 0- 40 988 24 7 39.4 0- 60 1785 44 6 71.3 0- 90 2505 62 6 100.0 90-180.0 0-180 2505 62 6 100.0
1 67 63 60 59 57 55 57 55 53 2 60 55 50 51 47 44 49 46 43 3 55 47 42 44 40 36 43 39 36 4 50 42 36 39 34 31 38 34 30 5 46 37 31 35 30 26 34 29 26 6 42 33 27 32 27 23 31 26 23 7 39 30 24 29 24 20 28 23 20 8 36 28 22 26 21 18 25 21 18 9 34 25 20 24 19 16 23 19 16 10 32 23 18 22 18 15 22 18 15
1 67 63 60 59 57 55 57 55 53 2 60 54 50 51 47 44 49 46 43 3 55 47 42 44 40 36 43 39 36 4 50 42 36 39 34 31 38 34 30 5 46 37 31 35 30 26 34 29 26 6 42 33 28 32 27 23 31 26 23 7 39 30 24 29 24 20 28 23 20 8 36 28 22 26 21 18 25 21 18 9 34 25 20 24 19 16 23 19 16 10 32 23 18 22 18 15 22 18 15
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1139. 1336. 1507. 55 968. 1312. 1580. 65 761. 1337. 1706. 75 569. 1426. 1930. 85 268. 1354. 1994.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1686. 1980. 2240. 55 1426. 1941. 2342. 65 1119. 1969. 2517. 75 833. 2082. 2819. 85 357. 1950. 2843.
CD
S
G
P
F
Body Style:
Ceiling Type:
Lamp Quantity 2=2 Lamp
Fits both Standard Grid
Ballast Type:
YD For NYC Code – Local 3 Manufactu ed
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Reflector – baked white polyester enamel, minimum 86% reflectance. Rust preventative undercoating. Lamp Shield – baked white polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .63. To reduce glare the average brightness at 65° shall not exceed 1706 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 76.1%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.