Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Static, 1, 2 or 3 Lamp T8




Exposed T-bar by others
Exposed T-bar by o hers
1-1/2" max.
Acoustical material by o hers
1-7/8" max.
Acoustical material by others
* For flush mounting when using 9/16" Exposed T-Grid ceiling system consult factory
exposed slot t-grid ceiling

T-bar by o hers
The fixture affixes to the outside of a ceiling's t bar and will not detach acting like an earthquake clip

T-bar by o hers
Job Name:
Lamp shield hinges either side
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket
Static, 1, 2 or 3 Lamp T8
Model No. CDS2GPF217UNVHI LER = FP - 46.6 IW - 30.8 BF - 0.88 Comparative yearly lighting ene gy cost per
Model No. CDS2GPF317UNVH3 LER = FP - 42.6 IW - 43.9 BF - 0.88 Comparative yearly lighting ene gy cost per
CANDELA DISTRIBUTION
1000 lumens = $5.15
1000 lumens = $5.63


Report Number: G2007131 Catalog Number: CDS2GPF217UNVHI Lamps: (2) F17T8 Luminaire: Coffaire Drop Basket Ballast: QTP2X17T8/UNV ISN SC Report is based on 1375 Lumens per lamp. Efficiency: 69.4% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
Report Number: G2007133 Catalog Number: CDS2GPF317UNVH3 Lamps: (3) F17T8 Luminaire: Coffaire Drop Basket Ballast: QTP3X17T8/UNV ISN SC Report is based on 1375 Lumens per lamp. Efficiency: 55.5% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
0 506 506 506
0 731 731 731
5 503 504 504 48
5 726 727 729 69
15 478 484 491 137
15 688 698 708 197
25 431 448 467 207
25 621 644 669 297
35 368 400 432 251
35 530 573 616 359
45 294 344 390 265
45 419 489 552 376
55 210 285 343 251
55 298 400 479 353
65 130 227 292 217
65 180 313 399 299
75 69 169 231 168
75 93 226 307 224
85 18 91 135 89
85 23 117 174 116
90 2 31 59
90 3 40 75
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL LUMEN SUMMARY
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 392 14 2 24 0 0- 40 642 23.4 39 3 0- 60 1158 42 1 70 9 0- 90 1633 59.4 100 0 90-180-180 1633 59.4 100 0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 564 13 7 24.6 0- 40 922 22.4 40.3 0- 60 1651 40 0 72.1 0- 90 2290 55 5 100.0 90-180.0 0-180 2290 55 5 100.0
1 62 60 57 56 54 52 54 52 50 2 57 52 47 48 45 42 46 43 41 3 52 45 40 42 38 34 40 37 34 4 47 40 34 37 33 29 36 32 29 5 43 35 30 33 28 25 32 28 25 6 40 32 26 30 25 22 29 25 21 7 37 29 23 27 23 19 26 22 19 8 34 26 21 25 20 17 24 20 17 9 32 24 19 23 18 15 22 18 15 10 30 22 17 21 17 14 21 17 14
1 59 56 53 53 50 49 50 49 47 2 54 48 44 45 42 39 43 41 38 3 49 42 37 40 36 32 38 35 32 4 44 37 32 35 31 27 34 30 27 5 41 33 28 31 27 24 30 26 23 6 38 30 25 28 24 21 27 23 20 7 35 27 22 26 21 18 25 21 18 8 32 25 20 23 19 16 23 19 16 9 30 23 18 22 17 15 21 17 15 10 28 21 16 20 16 13 19 16 13
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1054. 1280. 1451. 55 924. 1254. 1510. 65 727. 1270. 1634. 75 553. 1353. 1850. 85 268. 1354. 2009.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1559. 1820. 2054. 55 1312. 1761. 2108. 65 1007. 1751. 2232. 75 745. 1810. 2459. 85 342. 1741. 2590.
CD
S
G
P
F
Body Style:
Ceiling Type:
Lamp Quantity 1=1 Lamp 2=2 Lamp 3=3 Lamp
Fits both Standard Grid
Ballast Type:
YD For NYC Code – Local 3 Manufactu ed
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Reflector – baked white polyester enamel, minimum 86% reflectance. Rust preventative undercoating. Lamp Shield – baked white polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications Performance: In an installation of 2 lamp 17W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .60. To reduce glare the average brightness at 65° shall not exceed 1634 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 76%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.