JA
Lightolier logo
公式取扱説明書

Lightolier CDS2GPF228

2 ページ·110 KB·インテリア家具・調度品·PDF·EN
Lightolier CDS2GPF228
目次 18セクション Coffaire Drop Basket Recessed Fluorescent CDS2GPF228 or 254 · Page 1 of 2 Direct/Indirect – 2' x 4' with Perforated Basket · Static, 1, 2 or 3 Lamp T5 · Mounting Methods Dimensions · … 表示非表示
Page 1 of the Lightolier CDS2GPF228 user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Coffaire Drop Basket Recessed Fluorescent CDS2GPF228 or 254

Page 1 of 2 Direct/Indirect – 2' x 4' with Perforated Basket

Static, 1, 2 or 3 Lamp T5

  • Features
  • Direct/indirect lamp shield appearance with soft contoured interior.
  • Perforated mesh lamp shield with white acrylic overlay.
  • 69.9% efficient (2 lamp 28W T5).
  • 66.4% efficient (2 lamp 54W T5HO).
  • Only 2-1/4" plenum depth.
  • Same fixture fits both G and T ceiling types.
  • Fits flush to face of slot grid (T) ceiling.
  • Lamp shield hinges from either side.
  • Wiring access plate standard.
  • Optional DALI ballast iGEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
  • Construction to meet Chicago Plenum available.
  • Meets NYC Code requirements.
  • Not for continuous row mounting.
Lightolier CDS2GPF228 — Coffaire Drop Basket Recessed Fluorescent CDS2GPF228 or 254 diagram (page 1)
図 1 · Coffaire Drop Basket Recessed Fluorescent CDS2GPF228…

Mounting Methods Dimensions

Lightolier CDS2GPF228 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier CDS2GPF228 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions
Lightolier CDS2GPF228 — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

Exposed T-bar by others

Exposed T-bar by o hers

1-1/2" max.

Acoustical material by o hers

1-7/8" max.

Acoustical material by others

* For flush mounting when using 9/16" Exposed T-Grid ceiling system consult factory

exposed slot t-grid ceiling

Features

Lightolier CDS2GPF228 — Features diagram (page 1)
図 5 · Features

T-bar by o hers

The fixture affixes to the outside of a ceiling's t bar and will not detach acting like an earthquake clip

Lightolier CDS2GPF228 — Features diagram (page 1)
図 6 · Features

T-bar by o hers

Job Information Type:

Job Name:

Lamp shield hinges either side

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-82
Show 6 more labels / short text on this page
15/16" * · 24" · 9/16" · exposed t-grid ceiling · 24" · 10/07
Page 2 of the Lightolier CDS2GPF228 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Coffaire Drop Basket Recessed Fluorescent CDS2GPF228 or 254

Page 2 of 2 Direct/Indirect – 2' x 4' with Perforated Basket

Static, 1, 2 or 3 Lamp T5

Model No. CDS2GPF228UNVPG LER = FP - 33.2 IW - 122.1 BF - 1.0 Comparative yearly lighting ene gy cost per

Model No. CDS2GPF254UNVPG LER = FP - 54.6 IW - 121.6 BF - 1.0 Comparative yearly lighting ene gy cost per

CANDELA DISTRIBUTION

CANDELA DISTRIBUTION

1000 lumens = $7.29

1000 lumens = $4.40

Lightolier CDS2GPF228 — CANDELA DISTRIBUTION diagram (page 2)
図 7

0.0 45.0 90.0 FLUX

Lightolier CDS2GPF228 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 8

0.0 45.0 90.0 FLUX

Report Number: G2007118 Catalog Number: CDS2GPF228UNVPG Lamps: (2) F28T5 Luminaire: Coffaire Drop Basket Ballast: B228PUNV-D Report is based on 2900 Lumens per lamp. Efficiency: 69.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400

Report Number: G2007117 Catalog Number: CDS2GPF254UNVPG Lamps: (2) F54T5HO Luminaire: Coffaire Drop Basket Ballast: B254PUNV-D (Universal) Report is based on 5000 Lumens per lamp. Efficiency: 66.4% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400

0 1225 1225 1225

0 2020 2020 2020

5 1217 1219 1222 116

5 2007 2008 2012 191

15 1159 1174 1190 332

15 1913 1934 1960 547

25 1055 1093 1134 504

25 1737 1799 1865 830

35 907 982 1055 615

35 1494 1616 1735 1011

45 728 854 956 655

45 1196 1402 1572 1076

55 526 717 850 630

55 860 1176 1394 1033

65 326 588 728 554

65 532 960 1188 905

75 163 447 563 431

75 264 724 903 698

85 39 219 309 220

85 60 349 490 348

90 5 71 142

90 7 113 222

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 0- 30 952 16.4 23 5 0- 40 1567 27 0 38 6 0- 60 2852 49 2 70 3 0- 90 4057 69 9 100 0 90-180-180 4057 69 9 100 0

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 0- 30 1568 15 7 23.6 0- 40 2579 25 8 38.9 0- 60 4687 46 9 70.6 0- 90 6639 66.4 100.0 90-180.0 0-180 6639 66.4 100.0

1 75 71 67 66 63 61 63 61 59 2 67 61 55 57 52 49 54 51 48 3 61 53 46 49 44 40 47 43 39 4 55 46 40 44 38 34 42 37 33 5 51 41 34 39 33 29 37 32 29 6 47 37 30 35 29 25 34 29 25 7 43 33 27 32 26 22 31 26 22 8 40 30 24 29 24 20 28 23 20 9 38 28 22 27 21 18 26 21 18 10 35 26 20 25 20 16 24 19 16

1 71 67 64 63 60 58 60 58 56 2 64 58 52 54 50 46 52 48 45 3 58 50 44 47 42 38 45 41 38 4 53 44 38 41 36 32 40 35 32 5 48 39 33 37 32 28 36 31 27 6 45 35 29 33 28 24 32 27 24 7 41 32 26 30 25 21 29 25 21 8 38 29 23 28 23 19 27 22 19 9 36 27 21 25 20 17 25 20 17 10 34 25 19 23 19 15 23 18 15

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 956. 958. 935. 55 747. 838. 844. 65 521. 741. 758. 75 308. 623. 636. 85 94. 365. 394.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2222. 2539. 2776. 55 1929. 2544. 2913. 65 1564. 2681. 3158. 75 1179. 2978. 3442. 85 594. 2890. 3485.

Ordering Information Explanation of Catalog Number. Example: CDS2GPF228UNVPG

CD

S

G

P

F

Body Style:

Ceiling Type:

Lamp Quantity 1=1 Lamp 2=2 Lamp 3=3 Lamp Ballast Type:

Lamp(By Others) 28 =T5 28W 54 =T5HO 54W (Nominal 48")
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog

Fits both Standard Grid

no., ie(GLR)

CD Standard Coffaire Drop Basket

YD For NYC Code – Local 3 Manufactu ed

†Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only)

Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.

Specifications (continued) Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Rust preventative undercoating. Reflector – low irides- cence specular aluminum 95% reflectance. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.

Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 758 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 76.5%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-84
Show 11 more labels / short text on this page
Coffaire Drop · Fixture · Perforated · Flat White · Basket Direct/Indi ect · S = Static · Width · Lamp Shield · Reflector · Recessed · and Slot Grid
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier CDS2GPF228について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier CDS2GPF228に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier CDS2GPF228 取扱説明書(PDF)

2 ページ·110 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…