Page 1 of 2 Direct/Indirect – 2' x 4' with Perforated Basket
Static, 1, 2 or 3 Lamp T5




Exposed T-bar by others
Exposed T-bar by o hers
1-1/2" max.
Acoustical material by o hers
1-7/8" max.
Acoustical material by others
* For flush mounting when using 9/16" Exposed T-Grid ceiling system consult factory
exposed slot t-grid ceiling

T-bar by o hers
The fixture affixes to the outside of a ceiling's t bar and will not detach acting like an earthquake clip

T-bar by o hers
Job Name:
Lamp shield hinges either side
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 2' x 4' with Perforated Basket
Static, 1, 2 or 3 Lamp T5
Model No. CDS2GPF228UNVPG LER = FP - 33.2 IW - 122.1 BF - 1.0 Comparative yearly lighting ene gy cost per
Model No. CDS2GPF254UNVPG LER = FP - 54.6 IW - 121.6 BF - 1.0 Comparative yearly lighting ene gy cost per
CANDELA DISTRIBUTION
1000 lumens = $7.29
1000 lumens = $4.40


Report Number: G2007118 Catalog Number: CDS2GPF228UNVPG Lamps: (2) F28T5 Luminaire: Coffaire Drop Basket Ballast: B228PUNV-D Report is based on 2900 Lumens per lamp. Efficiency: 69.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400
Report Number: G2007117 Catalog Number: CDS2GPF254UNVPG Lamps: (2) F54T5HO Luminaire: Coffaire Drop Basket Ballast: B254PUNV-D (Universal) Report is based on 5000 Lumens per lamp. Efficiency: 66.4% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400
0 1225 1225 1225
0 2020 2020 2020
5 1217 1219 1222 116
5 2007 2008 2012 191
15 1159 1174 1190 332
15 1913 1934 1960 547
25 1055 1093 1134 504
25 1737 1799 1865 830
35 907 982 1055 615
35 1494 1616 1735 1011
45 728 854 956 655
45 1196 1402 1572 1076
55 526 717 850 630
55 860 1176 1394 1033
65 326 588 728 554
65 532 960 1188 905
75 163 447 563 431
75 264 724 903 698
85 39 219 309 220
85 60 349 490 348
90 5 71 142
90 7 113 222
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL LUMEN SUMMARY
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 952 16.4 23 5 0- 40 1567 27 0 38 6 0- 60 2852 49 2 70 3 0- 90 4057 69 9 100 0 90-180-180 4057 69 9 100 0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 1568 15 7 23.6 0- 40 2579 25 8 38.9 0- 60 4687 46 9 70.6 0- 90 6639 66.4 100.0 90-180.0 0-180 6639 66.4 100.0
1 75 71 67 66 63 61 63 61 59 2 67 61 55 57 52 49 54 51 48 3 61 53 46 49 44 40 47 43 39 4 55 46 40 44 38 34 42 37 33 5 51 41 34 39 33 29 37 32 29 6 47 37 30 35 29 25 34 29 25 7 43 33 27 32 26 22 31 26 22 8 40 30 24 29 24 20 28 23 20 9 38 28 22 27 21 18 26 21 18 10 35 26 20 25 20 16 24 19 16
1 71 67 64 63 60 58 60 58 56 2 64 58 52 54 50 46 52 48 45 3 58 50 44 47 42 38 45 41 38 4 53 44 38 41 36 32 40 35 32 5 48 39 33 37 32 28 36 31 27 6 45 35 29 33 28 24 32 27 24 7 41 32 26 30 25 21 29 25 21 8 38 29 23 28 23 19 27 22 19 9 36 27 21 25 20 17 25 20 17 10 34 25 19 23 19 15 23 18 15
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 956. 958. 935. 55 747. 838. 844. 65 521. 741. 758. 75 308. 623. 636. 85 94. 365. 394.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2222. 2539. 2776. 55 1929. 2544. 2913. 65 1564. 2681. 3158. 75 1179. 2978. 3442. 85 594. 2890. 3485.
CD
S
G
P
F
Body Style:
Ceiling Type:
Lamp Quantity 1=1 Lamp 2=2 Lamp 3=3 Lamp Ballast Type:
Fits both Standard Grid
YD For NYC Code – Local 3 Manufactu ed
†Instant Start (120, 277 or UNV) ††Program Rapid Start (UNV only)
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Rust preventative undercoating. Reflector – low irides- cence specular aluminum 95% reflectance. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 758 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 76.5%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.