Page 1 of 2 Direct/Indirect – 2' x 4' with Perforated Basket
Static, 1, 2 or 3 Lamp T8




Exposed T-bar by others
Exposed T-bar by o hers
1-1/2" max.
Acoustical material by o hers
1-7/8" max.
Acoustical material by others
* For flush mounting when using 9/16" Exposed T-Grid ceiling system consult factory
exposed slot t-grid ceiling

T-bar by o hers
The fixture affixes to the outside of a ceiling's t bar and will not detach acting like an earthquake clip

T-bar by o hers
Job Name:
Lamp shield hinges either side
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 2' x 4' with Perforated Basket
Static, 1, 2 or 3 Lamp T8
Model No. CDS2GPF232UNVHI LER = FP - 64.7 IW - 50.4 BF - 0.88 Comparative yearly lighting ene gy cost per
Model No. CDS2GPF332UNVH3 LER = FP - 38.9 IW - 122.0 BF - 0.88 Comparative yearly lighting ene gy cost per
CANDELA DISTRIBUTION
1000 lumens = $3.71
1000 lumens = $6.17


Report Number: G2007114 Catalog Number: CDS2GPF232UNVHI Lamps: (2) F28T8 Luminaire: Coffaire Drop Basket Ballast: QTP2X32T8/UNV ISN SC Report is based on 2725 Lumens per lamp. Efficiency: 68.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400
Report Number: G2007116 Catalog Number: CDS2GPF332UNVH3 Lamps: (3) F28T8 Luminaire: Coffaire Drop Basket Ballast: QTP3X32T8/UNV ISN SC Report is based on 2725 Lumens per lamp. Efficiency: 66.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.880 23.400
0 1128 1128 1128
0 1706 1706 1706
5 1121 1122 1124 107
5 1695 1696 1698 161
15 1068 1081 1094 305
15 1612 1628 1648 460
25 970 1005 1041 463
25 1460 1508 1559 696
35 834 902 968 565
35 1253 1345 1435 842
45 668 784 878 601
45 999 1155 1284 886
55 481 658 776 576
55 716 952 1113 837
65 297 532 657 502
65 435 755 925 715
75 149 400 505 388
75 215 551 687 535
85 36 203 283 200
85 50 267 375 267
90 5 65 125
90 7 83 165
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL LUMEN SUMMARY
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 876 16 1 23 6 0- 40 1440 26.4 38 8 0- 60 2618 48 0 70 6 0- 90 3708 68 0 100 0 90-180-180 3708 68 0 100 0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 1317 16 1 24.4 0- 40 2159 26.4 40.0 0- 60 3883 47 5 71.9 0- 90 5399 66 0 100.0 90-180.0 0-180 5399 66 0 100.0
1 72 69 65 64 61 59 61 59 57 2 65 59 54 55 51 47 53 49 46 3 59 51 45 48 43 39 46 42 38 4 54 45 39 42 37 33 41 36 32 5 50 40 34 38 32 28 36 32 28 6 46 36 30 34 29 25 33 28 24 7 42 33 26 31 26 22 30 25 22 8 39 30 24 28 23 19 27 23 19 9 37 27 21 26 21 17 25 21 17 10 34 25 20 24 19 16 23 19 16
1 71 67 64 63 60 58 60 58 56 2 64 58 53 54 50 47 52 48 46 3 58 50 44 47 42 39 45 41 38 4 53 44 38 42 37 33 40 36 32 5 48 39 33 37 32 28 36 31 28 6 45 35 29 34 28 24 32 28 24 7 41 32 26 30 25 22 29 25 21 8 39 29 23 28 23 19 27 22 19 9 36 27 21 26 21 17 25 20 17 10 34 25 19 24 19 16 23 19 16
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1241. 1420. 1550. 55 1079. 1424. 1622. 65 873. 1486. 1747. 75 665. 1645. 1925. 85 357. 1681. 2013.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1856. 2091. 2267. 55 1606. 2060. 2326. 65 1279. 2108. 2459. 75 960. 2266. 2618. 85 495. 2211. 2667.
CD
S
G
P
F
Body Style:
Ceiling Type:
Lamp Quantity 1=1 Lamp 2=2 Lamp 3=3 Lamp Ballast Type:
Fits both Standard Grid
YD For NYC Code – Local 3 Manufactu ed
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Rust preventative undercoating. Reflector – low irides- cence specular aluminum 95% reflectance. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .69. To reduce glare the average brightness at 65° shall not exceed 1747 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 76.4%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.