Coffaire II Recessed Fluorescent CFA2GPF217 or 317

Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket

Air Supply and Return, 2 Lamp or 3 Lamp, T8

  • Features
  • Direct/indirect lamp shield appearance with soft contoured interior.
  • Perforated mesh lamp shield with white acrylic overlay.
  • Contoured body and ends.
  • Air supply and return.
  • Air return slots located above lamp shield.
  • Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
  • 61.7% efficient (2 lamp T8).
  • 55.9% efficient (3 lamp T8).
  • Spacing to mounting ratio 1.4 (2 lamp).
  • Spacing to mounting ratio 1.3 (3 lamp).
  • Only 5" deep.
  • Tension screws secure ends to body.
  • Perforated lamp shield hinges from either side.
  • Can be continuous row mounted.
  • Built-in earthquake clips.
  • Ballast accessible from room side.
  • Optional supply air slot cover.
  • Meets NYC Code.
  • Construction to meet Chicago Plenum requirements is available.
Lightolier CFA2GPF217 or 317 — Coffaire II Recessed Fluorescent CFA2GPF217 or 317 diagram (page 1)
図 1 · Coffaire II Recessed Fluorescent CFA2GPF217 or 317

Mounting Methods Dimensions

Lightolier CFA2GPF217 or 317 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier CFA2GPF217 or 317 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions
Lightolier CFA2GPF217 or 317 — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

2" x 2-1/2" Access Plate with 7/8" dia. K.O.

Lightolier CFA2GPF217 or 317 — Mounting Methods Dimensions diagram (page 1)
図 5 · Mounting Methods Dimensions
  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-36

2-1/2" (64mm) · 05/07

Page 2 of the Lightolier CFA2GPF217 or 317 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Coffaire II Recessed Fluorescent CFA2GPF217 or 317

Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket

Air Supply and Return, 2 Lamp or 3 Lamp, T8

Model No. CFA2GPF217120SO LER = FP - 50.2 IW - 30.08 BF - 0.93 Comparative yearly lighting energy cost per

Model No. CFA2GPF317120O3 LER = FP - 48.7 IW - 46.5 BF - 1.00 Comparative yearly lighting energy cost per

CANDELA DISTRIBUTION 0

1000 lumens = $4.78

1000 lumens = $0.00

CANDELA DISTRIBUTION 0

Lightolier CFA2GPF217 or 317 — CANDELA DISTRIBUTION 0 diagram (page 2)
図 6

0.0 45.0 90.0 FLUX

Lightolier CFA2GPF217 or 317 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 7

0.0 45.0 90.0 FLUX

Report NumberG2004248 Catalog Number: CFA2GPF217120SO Lamps: F017/41K Luminaire: Coffaire 2'x2' with perforated
Report NumberG2004249 Catalog Number: CFA2GPF317120O3 Lamps: F017/41K Luminaire: Coffaire with perforated

0 572 572 572

0 800 800 800

5 569 570 570 54

5 794 796 798 76

basket Ballast: Triad C240SI120 Report is based on 1350 Lumens per lamp. Efficiency: 61.7% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920

basket Ballast: Triad B332I120 Report is based on 1350 Lumens per lamp. Efficiency: 55.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920

15 541 550 560 155

15 754 766 780 217

25 492 515 537 237

25 684 712 741 329

35 426 465 500 290

35 591 638 682 399

45 346 400 445 307

45 476 544 600 417

55 253 322 375 283

55 346 431 493 380

65 156 230 260 215

65 208 300 338 283

75 78 91 107 104

75 103 133 147 137

85 15 16 17 20

85 19 22 23 27

90

90

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

01 67 64 62 60 58 57 58 56 55 02 61 56 52 53 49 47 51 48 46 03 56 49 44 46 42 39 45 41 38 04 51 43 38 41 37 33 40 36 33 05 47 39 33 37 32 29 35 31 28 06 43 35 29 33 28 25 32 28 25 07 40 32 26 30 25 22 29 25 22 08 37 29 23 27 23 20 27 23 19 09 35 26 21 25 21 18 25 20 18 10 32 24 19 23 19 16 23 19 16

01 61 58 56 55 53 51 53 51 50 02 56 51 47 48 45 42 46 44 42 03 51 45 40 42 39 36 41 38 35 04 46 40 35 37 33 30 36 33 30 05 43 35 30 34 29 26 32 29 23 06 39 32 27 30 26 23 29 26 23 07 36 29 24 27 23 20 27 23 20 08 34 26 22 25 21 18 24 21 18 09 32 24 20 23 19 16 23 19 16 10 30 22 18 21 17 15 21 17 15

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

AVERAGE AVERAGE AVERAGE AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 446 16.5 26.8 00-040 736 27.3 44.2 00-060 1327 49.1 79.7 00-090 1665 61.7 100.0 90-180 0000 0.0 000.0 00-180 1665 61.7 100.0

AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 621 15.3 27.4 00-040 1020 25.2 45.1 00-060 1817 44.9 80.3 00-090 2264 55.9 100.0 90-180 0000 00.0 000.0 00-180 2264 55.9 100.0

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1443. 1668. 1856. 55 1301. 1656. 1928. 65 1089. 1605. 1815. 75 889. 1037. 1219. 85 508. 541. 575.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1985. 2269. 2503. 55 1779. 2216. 2535. 65 1452. 2094. 2359. 75 1174. 1516. 1675. 85 643. 745. 778.

Ordering Information Explanation of Catalog Number. Example: CFA2GPF217120SO

A

G

P

F

Coffaire II:

Body StyleA = Air Supply
Ceiling TypeStandard Grid

Lamp Quantity 2=2 Lamp 3=3 Lamp

Lamp(By Others)
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog
Direct/ IndirectRecessed with Perforated

17=T8 (Nominal 24")

no., ie(GLR)

Ballast Type:

CF Standard Coffaire II

CN For NYC Code –Local 3 Manufactured

Options/Accessories Optional supply air slot cover: Order Catalog Number: CACS-2 Fusing: Internal fast blow fusing: SUFFIX: GLR.

Specifications (continued) Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating. Lamp Shield –white. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX: C. Dust Shield: See Folio Number: OA50-20

Specifications Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To reduce glare the average brightness at 65° shall not exceed 1815 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.2%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-36
Show 7 more labels / short text on this page
Fixture · Perforated · Flat White Reflector · Width · Lamp Shield · and Return · Mesh Shield
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier CFA2GPF217 or 317について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier CFA2GPF217 or 317に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier CFA2GPF217 or 317 取扱説明書(PDF)

2 ページ·125 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…