Lightolier CFA2GPF228

2 ページ·121 KB·インテリア家具・調度品·PDF·EN
Lightolier CFA2GPF228
目次 15セクション Coffaire II Recessed Fluorescent CFA2GPF228 or 254 · Page 1 of 2 Direct/Indirect – 2' x 4' with Perforated Basket · Air Supply and Return, 2 Lamp T5 · Mounting Methods Dimensions · … 表示非表示
Page 1 of the Lightolier CFA2GPF228 user manual — Mounting Methods Dimensions
1ページ · クリックして拡大
1ページ

Coffaire II Recessed Fluorescent CFA2GPF228 or 254

Page 1 of 2 Direct/Indirect – 2' x 4' with Perforated Basket

Air Supply and Return, 2 Lamp T5

  • Features
  • Direct/indirect lamp shield appearance with soft contoured interior.
  • Perforated mesh lamp shield with white acrylic overlay.
  • Contoured body and ends.
  • Air supply and return.
  • Air return slots located above lamp shield.
  • Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
  • 65.0% efficient (2 lamp T5, 28W).
  • 70.8% efficient (2 lamp T5, 54W).
  • Spacing to mounting ratio 1.3 (2 lamp).
  • Only 5" deep.
  • Tension screws secure ends to body.
  • Perforated lamp shield hinges from either side.
  • Can be continuous row mounted.
  • Built-in earthquake clips.
  • Ballast accessible from room side.
  • Optional supply air slot cover.
  • Meets NYC Code.
  • Construction to meet Chicago Plenum requirements is available.
Lightolier CFA2GPF228 — Coffaire II Recessed Fluorescent CFA2GPF228 or 254 diagram (page 1)
図 1 · Coffaire II Recessed Fluorescent CFA2GPF228 or 254

Mounting Methods Dimensions

Lightolier CFA2GPF228 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier CFA2GPF228 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions
Lightolier CFA2GPF228 — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

2" x 2-1/2" Access Plate with 7/8" dia. K.O.

Lightolier CFA2GPF228 — Mounting Methods Dimensions diagram (page 1)
図 5 · Mounting Methods Dimensions
  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-42

2-1/2" (64mm) · 48" (1219mm) · 05/07

Page 2 of the Lightolier CFA2GPF228 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Coffaire II Recessed Fluorescent CFA2GPF228 or 254

Page 2 of 2 Direct/Indirect – 2' x 4' with Perforated Basket

Air Supply and Return, 2 Lamp T5

Model No. CFA2GPF228120WA LER = FP - 57.2 IW - 54.9 BF - 0.93 Comparative yearly lighting energy cost per

Model No. CFA2GPF254120PG LER = FP - 50.7 IW - 123.2 BF - 1.00 Comparative yearly lighting energy cost per

CANDELA DISTRIBUTION 0

1000 lumens = $4.20

1000 lumens = $4.73

CANDELA DISTRIBUTION 0

Lightolier CFA2GPF228 — CANDELA DISTRIBUTION 0 diagram (page 2)
図 6

0.0 45.0 90.0 FLUX

Lightolier CFA2GPF228 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 7

0.0 45.0 90.0 FLUX

Report NumberG2004258 Catalog Number: CFA2GPF228120WA Lamps: F28T5 Luminaire: Coffaire direct/indirect with
Report NumberG2004261 Catalog Number: CFA2GPF254120PG Lamps: FP54/835 Luminaire: Coffaire direct/indirect with

0 1151 1151 1151

0 2082 2082 2082

5 1143 1146 1150 109

5 2069 2073 2078 197

perforated basket Ballast: WA Report is based on 2600 Lumens per lamp. Efficiency: 65.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800

15 1091 1108 1125 313

perforated basket Ballast: QT2X54/120 Report is based on 4400 Lumens per lamp. Efficiency: 70.8% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 46.920 22.920

15 1986 2006 2035 568

25 999 1038 1076 479

25 1834 1885 1947 871

35 871 940 997 586

35 1621 1711 1803 1072

45 714 814 880 622

45 1354 1488 1593 1143

55 531 661 730 578

55 1040 1212 1324 1071

65 333 476 492 441

65 690 878 905 828

75 163 206 199 213

75 323 388 373 401

85 32 34 34 40

85 63 67 65 78

90 2 2 2

90

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

01 71 68 65 64 62 60 61 59 58 02 64 59 55 55 52 49 53 51 48 03 59 52 46 49 45 41 47 43 40 04 54 46 40 43 39 35 42 38 34 05 49 41 35 39 34 30 37 33 30 06 45 37 31 35 30 26 34 29 26 07 42 33 27 32 27 23 31 26 23 08 39 30 25 29 24 21 28 24 20 09 36 28 22 27 22 19 26 22 18 10 34 26 20 25 20 17 24 20 17

01 77 74 71 69 67 65 66 65 63 02 70 64 59 60 57 53 58 55 52 03 64 56 50 53 48 44 51 47 44 04 58 50 43 47 42 348 45 41 37 05 53 44 38 42 37 32 40 36 32 06 49 40 33 38 32 28 37 32 28 07 46 36 30 34 29 25 33 28 25 08 42 33 27 31 26 22 30 26 22 09 40 30 24 29 24 20 28 23 20 10 37 28 22 27 22 18 26 21 18

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

AVERAGE AVERAGE AVERAGE AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 901 17.3 26.6 00-040 1487 28.6 44.0 00-060 2687 51.7 79.4 00-090 3382 65.0 100.0 90-180 0000 0.0 000.0 00-180 3382 65.0 100.0

AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 1636 18.6 26.3 00-040 2708 30.8 43.5 00-060 4921 55.9 79.0 00-090 6229 70.8 100.0 90-180 0000 00.0 000.0 00-180 6229 70.8 100.0

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1466. 1672. 1807. 55 1344. 1673. 1848. 65 1144. 1636. 1690. 75 915. 1156. 1116. 85 533. 566. 566.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2759. 3032. 3246. 55 2612. 3044. 3326. 65 2352. 2993. 3085. 75 1798. 2160. 2076. 85 1041. 1108. 1075.

Ordering Information Explanation of Catalog Number. Example: CFA2GPF228120WA

A

G

P

F

Coffaire II:

Body StyleA = Air Supply
Ceiling TypeStandard Grid

Lamp Quantity 2=2 Lamp

Lamp(By Others)
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog
Direct/ IndirectRecessed with Perforated

28=28W T5 54=54W T5 (Nominal 48")

no., ie(GLR)

Ballast Type:

CF Standard Coffaire II

CN For NYC Code – Local 3 Manufactured

Options/Accessories Optional supply air slot cover: Order Catalog Number: CACS-4. Fusing: Internal fast blow fusing: SUFFIX: GLR.

Specifications (continued) Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating. Lamp Shield –white. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX: C. Dust Shield: See Folio Number: OA50-20

Specifications Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .66. To reduce glare the average brightness at 65° shall not exceed 2093 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.6%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-42
Show 7 more labels / short text on this page
Fixture · Perforated · Flat White Reflector · Width · Lamp Shield · and Return · Mesh Shield
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier CFA2GPF228について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier CFA2GPF228に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier CFA2GPF228 取扱説明書(PDF)

2 ページ·121 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…