Page 1 of 2 Direct/Indirect – 2' x 4' with Perforated Basket
Air Supply and Return, 2 Lamp T5




2" x 2-1/2" Access Plate with 7/8" dia. K.O.

2-1/2" (64mm) · 48" (1219mm) · 05/07

Page 2 of 2 Direct/Indirect – 2' x 4' with Perforated Basket
Air Supply and Return, 2 Lamp T5
Model No. CFA2GPF228120WA LER = FP - 57.2 IW - 54.9 BF - 0.93 Comparative yearly lighting energy cost per
Model No. CFA2GPF254120PG LER = FP - 50.7 IW - 123.2 BF - 1.00 Comparative yearly lighting energy cost per
1000 lumens = $4.20
1000 lumens = $4.73


0 1151 1151 1151
0 2082 2082 2082
5 1143 1146 1150 109
5 2069 2073 2078 197
perforated basket Ballast: WA Report is based on 2600 Lumens per lamp. Efficiency: 65.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800
15 1091 1108 1125 313
perforated basket Ballast: QT2X54/120 Report is based on 4400 Lumens per lamp. Efficiency: 70.8% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 55 65 Plane: 0-Deg 90-Deg Luminous Length: 46.920 22.920
15 1986 2006 2035 568
25 999 1038 1076 479
25 1834 1885 1947 871
35 871 940 997 586
35 1621 1711 1803 1072
45 714 814 880 622
45 1354 1488 1593 1143
55 531 661 730 578
55 1040 1212 1324 1071
65 333 476 492 441
65 690 878 905 828
75 163 206 199 213
75 323 388 373 401
85 32 34 34 40
85 63 67 65 78
90 2 2 2
90
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 71 68 65 64 62 60 61 59 58 02 64 59 55 55 52 49 53 51 48 03 59 52 46 49 45 41 47 43 40 04 54 46 40 43 39 35 42 38 34 05 49 41 35 39 34 30 37 33 30 06 45 37 31 35 30 26 34 29 26 07 42 33 27 32 27 23 31 26 23 08 39 30 25 29 24 21 28 24 20 09 36 28 22 27 22 19 26 22 18 10 34 26 20 25 20 17 24 20 17
01 77 74 71 69 67 65 66 65 63 02 70 64 59 60 57 53 58 55 52 03 64 56 50 53 48 44 51 47 44 04 58 50 43 47 42 348 45 41 37 05 53 44 38 42 37 32 40 36 32 06 49 40 33 38 32 28 37 32 28 07 46 36 30 34 29 25 33 28 25 08 42 33 27 31 26 22 30 26 22 09 40 30 24 29 24 20 28 23 20 10 37 28 22 27 22 18 26 21 18
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONAL LUMEN SUMMARY
AVERAGE AVERAGE AVERAGE AVERAGE
ZONE LUMENS % LAMP % FIXT 00-030 901 17.3 26.6 00-040 1487 28.6 44.0 00-060 2687 51.7 79.4 00-090 3382 65.0 100.0 90-180 0000 0.0 000.0 00-180 3382 65.0 100.0
ZONE LUMENS % LAMP % FIXT 00-030 1636 18.6 26.3 00-040 2708 30.8 43.5 00-060 4921 55.9 79.0 00-090 6229 70.8 100.0 90-180 0000 00.0 000.0 00-180 6229 70.8 100.0
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1466. 1672. 1807. 55 1344. 1673. 1848. 65 1144. 1636. 1690. 75 915. 1156. 1116. 85 533. 566. 566.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2759. 3032. 3246. 55 2612. 3044. 3326. 65 2352. 2993. 3085. 75 1798. 2160. 2076. 85 1041. 1108. 1075.
A
G
P
F
Coffaire II:
Lamp Quantity 2=2 Lamp
28=28W T5 54=54W T5 (Nominal 48")
Ballast Type:
CN For NYC Code – Local 3 Manufactured
Options/Accessories Optional supply air slot cover: Order Catalog Number: CACS-4. Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating. Lamp Shield –white. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX: C. Dust Shield: See Folio Number: OA50-20
Specifications Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .66. To reduce glare the average brightness at 65° shall not exceed 2093 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.6%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.