Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket Air Supply and Return, 2 Lamp or 3 Lamp, Twin Tube T5




2" x 2-1/2" Access Plate with 7/8" dia. K.O.

2-1/2" (64mm) · 05/07

Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket Air Supply and Return, 2 Lamp or 3 Lamp, Twin Tube T5
Model No. CFA2GPF2FT120SB LER = FP - 56.2 IW - 65.5 BF - 0.86 Comparative yearly lighting energy cost per
Model No. CFA2GPF3FT120X3 LER = FP - 41.2 IW - 111.1 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $4.27
1000 lumens = $5.85


0 1423 1423 1423
0 1878 1878 1878
5 1416 1416 1417 135
5 1848 1861 1878 177
basket Ballast: Triad C240SI120 Report is based on 3150 Lumens per lamp. Efficiency: 68.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920
15 1354 1369 1385 387
basket Ballast: UT340120 Report is based on 3150 Lumens per lamp. Efficiency: 55.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920
15 1746 1789 1826 506
25 1242 1283 1331 593
25 1582 1658 1726 766
35 1089 1168 1251 732
35 1364 1479 1582 927
45 897 1024 1130 786
45 1100 1258 1386 966
55 669 844 949 738
55 796 995 1125 874
65 423 607 665 569
65 474 686 753 641
75 200 295 300 290
75 218 299 326 304
85 37 53 56 61
85 40 49 50 59
90
90
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 74 71 68 66 64 62 64 62 60 02 67 62 57 58 54 51 56 53 50 03 61 54 48 51 46 43 49 45 42 04 56 48 41 45 40 36 43 39 36 05 51 42 36 40 35 31 39 34 31 06 47 38 32 36 31 27 35 30 27 07 44 34 28 33 28 24 32 27 24 08 41 31 25 30 25 21 29 24 21 09 38 29 23 28 23 19 27 22 19 10 36 26 21 25 21 17 25 20 17
01 60 58 55 54 52 51 52 51 49 02 55 50 47 47 45 42 46 43 41 03 50 44 40 42 38 35 40 37 35 04 46 39 34 37 33 30 36 32 30 05 42 35 30 33 29 26 32 29 26 06 39 32 27 30 26 23 29 25 23 07 36 29 24 27 23 20 26 23 20 08 34 26 21 25 21 18 24 21 18 09 31 24 19 23 19 16 22 19 16 10 29 22 18 21 17 15 21 17 15
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONAL LUMEN SUMMARY
AVERAGE AVERAGE AVERAGE AVERAGE
ZONE LUMENS % LAMP % FIXT 00-030 1115 17.7 26.0 00-040 1847 29.3 43.1 00-060 3370 53.5 78.6 00-090 4289 68.1 100.0 90-180 0000 0.0 000.0 00-180 4289 68.1 100.0
ZONE LUMENS % LAMP % FIXT 00-030 1449 15.3 27.8 00-040 2376 25.1 45.5 00-060 42316 44.6 80.8 00-090 5219 55.2 100.0 90-180 0000 00.0 000.0 00-180 5219 55.2 100.0
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3742. 4271. 4713. 55 3440. 4340. 4880. 65 2952. 4236. 4641. 75 2279. 3362. 3419. 85 1252. 1794. 1895.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4588. 5247. 5781. 55 4093. 5117. 5785. 65 3308. 4788. 5255. 75 2484. 3407. 3715. 85 1354. 1658. 1692.
A
G
P
F
FT
Coffaire II:
Lamp Quantity 2=2 Lamp 3=3 Lamp Ballast Type:
CN For NYC Code – Local 3 Manufactured
Options/Accessories Optional supply air slot cover: Order Catalog Number: CACS-2 Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating. Lamp Shield –white. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX C. Dust Shield: See Folio Number: OA50-20 Specifications Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 4641 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.0%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.