Lightolier CFA2GPF3FT
目次 14セクション Coffaire II Recessed Fluorescent CFA2GPF2FT or 3FT · Mounting Methods Dimensions · Coffaire II Recessed Fluorescent CFA2GP2FT or 3FT · CANDELA DISTRIBUTION 0 · … 表示非表示
Page 1 of the Lightolier CFA2GPF3FT user manual — Mounting Methods Dimensions
1ページ · クリックして拡大
1ページ

Coffaire II Recessed Fluorescent CFA2GPF2FT or 3FT

Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket Air Supply and Return, 2 Lamp or 3 Lamp, Twin Tube T5

  • Features
  • Direct/indirect lamp shield appearance with soft contoured interior.
  • Perforated mesh lamp shield with white acrylic overlay.
  • Contoured body and ends.
  • Air supply and return.
  • Air return slots located above lamp shield.
  • Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
  • 68.1% efficient (2 lamp TT5).
  • 55.2% efficient (3 lamp TT5).
  • Spacing to mounting ratio 1.4 (2 lamp).
  • Spacing to mounting ratio 1.3 (3 lamp).
  • Only 5" deep.
  • Tension screws secure ends to body.
  • Perforated lamp shield hinges from either side.
  • Can be continuous row mounted.
  • Built-in earthquake clips.
  • Ballast accessible from room side.
  • Optional supply air slot cover.
  • Meets NYC Code.
  • Construction to meet Chicago Plenum requirements is available.
Lightolier CFA2GPF3FT — Coffaire II Recessed Fluorescent CFA2GPF2FT or 3FT diagram (page 1)
図 1 · Coffaire II Recessed Fluorescent CFA2GPF2FT or 3FT

Mounting Methods Dimensions

Lightolier CFA2GPF3FT — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier CFA2GPF3FT — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions
Lightolier CFA2GPF3FT — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

2" x 2-1/2" Access Plate with 7/8" dia. K.O.

Lightolier CFA2GPF3FT — Mounting Methods Dimensions diagram (page 1)
図 5 · Mounting Methods Dimensions
  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-26

2-1/2" (64mm) · 05/07

Page 2 of the Lightolier CFA2GPF3FT user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Coffaire II Recessed Fluorescent CFA2GP2FT or 3FT

Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket Air Supply and Return, 2 Lamp or 3 Lamp, Twin Tube T5

Model No. CFA2GPF2FT120SB LER = FP - 56.2 IW - 65.5 BF - 0.86 Comparative yearly lighting energy cost per

Model No. CFA2GPF3FT120X3 LER = FP - 41.2 IW - 111.1 BF - 0.88 Comparative yearly lighting energy cost per

CANDELA DISTRIBUTION 0

1000 lumens = $4.27

1000 lumens = $5.85

CANDELA DISTRIBUTION 0

Lightolier CFA2GPF3FT — CANDELA DISTRIBUTION 0 diagram (page 2)
図 6

0.0 45.0 90.0 FLUX

Lightolier CFA2GPF3FT — 0.0 45.0 90.0 FLUX diagram (page 2)
図 7

0.0 45.0 90.0 FLUX

Report NumberG2004033 Catalog Number: CFA2GPF2FT120SB Lamps: F40 30BX/SPX35 Luminaire: Coffaire II with perforated
Report NumberG2004247 Catalog Number: CFA2GPF3FT120X3 Lamps: F40/TT5 Luminaire: Coffaire II with perforated

0 1423 1423 1423

0 1878 1878 1878

5 1416 1416 1417 135

5 1848 1861 1878 177

basket Ballast: Triad C240SI120 Report is based on 3150 Lumens per lamp. Efficiency: 68.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920

15 1354 1369 1385 387

basket Ballast: UT340120 Report is based on 3150 Lumens per lamp. Efficiency: 55.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920

15 1746 1789 1826 506

25 1242 1283 1331 593

25 1582 1658 1726 766

35 1089 1168 1251 732

35 1364 1479 1582 927

45 897 1024 1130 786

45 1100 1258 1386 966

55 669 844 949 738

55 796 995 1125 874

65 423 607 665 569

65 474 686 753 641

75 200 295 300 290

75 218 299 326 304

85 37 53 56 61

85 40 49 50 59

90

90

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

01 74 71 68 66 64 62 64 62 60 02 67 62 57 58 54 51 56 53 50 03 61 54 48 51 46 43 49 45 42 04 56 48 41 45 40 36 43 39 36 05 51 42 36 40 35 31 39 34 31 06 47 38 32 36 31 27 35 30 27 07 44 34 28 33 28 24 32 27 24 08 41 31 25 30 25 21 29 24 21 09 38 29 23 28 23 19 27 22 19 10 36 26 21 25 21 17 25 20 17

01 60 58 55 54 52 51 52 51 49 02 55 50 47 47 45 42 46 43 41 03 50 44 40 42 38 35 40 37 35 04 46 39 34 37 33 30 36 32 30 05 42 35 30 33 29 26 32 29 26 06 39 32 27 30 26 23 29 25 23 07 36 29 24 27 23 20 26 23 20 08 34 26 21 25 21 18 24 21 18 09 31 24 19 23 19 16 22 19 16 10 29 22 18 21 17 15 21 17 15

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

AVERAGE AVERAGE AVERAGE AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 1115 17.7 26.0 00-040 1847 29.3 43.1 00-060 3370 53.5 78.6 00-090 4289 68.1 100.0 90-180 0000 0.0 000.0 00-180 4289 68.1 100.0

AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 1449 15.3 27.8 00-040 2376 25.1 45.5 00-060 42316 44.6 80.8 00-090 5219 55.2 100.0 90-180 0000 00.0 000.0 00-180 5219 55.2 100.0

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3742. 4271. 4713. 55 3440. 4340. 4880. 65 2952. 4236. 4641. 75 2279. 3362. 3419. 85 1252. 1794. 1895.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4588. 5247. 5781. 55 4093. 5117. 5785. 65 3308. 4788. 5255. 75 2484. 3407. 3715. 85 1354. 1658. 1692.

Ordering Information Explanation of Catalog Number. Example: CFA2GPF2FT120SB

A

G

P

F

FT

Coffaire II:

Body StyleA = Air Supply
Ceiling TypeStandard Grid

Lamp Quantity 2=2 Lamp 3=3 Lamp Ballast Type:

Lamp(By Others)
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog no., ie: (GLR)
Direct/ IndirectRecessed with Perforated

CF Standard Coffaire II

CN For NYC Code – Local 3 Manufactured

Options/Accessories Optional supply air slot cover: Order Catalog Number: CACS-2 Fusing: Internal fast blow fusing: SUFFIX: GLR.

Specifications (continued) Finish: Chassis exterior – soft white post painted polyester powder. Cavity – soft white post painted polyester powder. Reflector – soft white post painted polyester powder, minimum 88% reflectance. Rust preventive undercoating. Lamp Shield –white. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX C. Dust Shield: See Folio Number: OA50-20 Specifications Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 4641 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.0%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 5/Folio M15-26
Show 7 more labels / short text on this page
Fixture · Perforated · Flat White Reflector · Width · Lamp Shield · and Return · Mesh Shield
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier CFA2GPF3FTについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier CFA2GPF3FTに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier CFA2GPF3FT 取扱説明書(PDF)

2 ページ·125 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…