Page 1 of 2 Direct/Indirect – 2' x 4' with Perforated Basket
Air Return/Static, 2 Lamp or 3 Lamp T8




Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others
exposed slot t-grid ceiling



2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
lamp shield hinges either side

Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
light stop-static models only

Page 2 of 2 Direct/Indirect – with Perforated Basket
Air Return/Static, 2 Lamp or 3 Lamp T8
Model No. CFH2GPF232120SO LER = FP - 54.7 IW - 58.0 BF - 0.87 Comparative yearly lighting energy cost per
Model No. CFH2GPF332120O3 LER = FP - 50.7 IW - 85 BF - 0.88 Comparative yearly lighting energy cost per
1000 lumens = $4.39
1000 lumens = $4.73


0 1179 1179 1179
0 1733 1733 1733
5 1172 1174 1176 112
5 1722 1725 1729 164
basket Ballast: Triad B232IUNV-HP, 58 watts Report is based on 2850 Lumens per lamp. Efficiency: 63.8% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.920 22.920
15 1120 1135 1151 321
basket Ballast: SYL QT3X32T8 120, 89.0 watts Report is based on 2850 Lumens per lamp. Efficiency: 60.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.920 22.920
15 1645 1668 1693 472
25 1028 1067 1105 492
25 1507 1563 1613 720
35 899 972 1031 606
35 1316 1412 1483 879
45 742 851 931 651
45 1076 1213 1310 930
55 555 705 794 618
55 801 983 1083 863
65 357 528 614 504
65 504 712 809 682
75 175 308 243 281
75 244 394 335 369
85 37 43 47 52
85 51 58 63 72
90
90
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 69 66 63 62 60 58 59 58 56 02 63 57 53 54 50 47 52 49 46 03 57 50 45 47 43 39 45 42 39 04 52 44 38 42 37 33 40 36 33 05 48 39 33 37 32 29 36 32 28 06 44 35 29 33 29 25 32 28 25 07 41 32 26 30 25 22 29 25 22 08 38 29 23 28 23 19 27 23 19 09 35 27 21 25 21 18 25 20 17 10 33 25 19 24 19 16 23 19 16
01 66 63 60 59 57 55 56 55 53 02 59 54 50 51 48 45 49 46 44 03 54 48 43 45 41 38 43 40 37 04 49 42 37 40 35 32 38 35 31 05 45 37 32 36 31 27 34 30 27 06 42 34 28 32 27 24 31 27 24 07 39 30 25 29 24 21 28 24 21 08 36 28 23 27 22 19 26 22 19 09 34 25 20 24 20 17 24 20 17 10 32 23 19 23 18 15 22 18 15
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONAL LUMEN SUMMARY
AVERAGE AVERAGE AVERAGE AVERAGE
ZONE LUMENS % LAMP % FIXT 00-030 925 16.2 25.4 00-040 1531 26.9 42.1 00-060 2800 49.1 77.0 00-090 3636 63.8 100.0 90-180 0000 0.0 000.0 00-180 3636 63.8 100.0
ZONE LUMENS % LAMP % FIXT 00-030 1356 15.9 26.3 00-040 2235 26.1 43.4 00-060 4027 47.1 78.2 00-090 5150 60.2 100.0 90-180 0000 00.0 000.0 00-180 5150 60.2 100.0
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1512. 1734. 1897. 55 1394. 1771. 1994. 65 1217. 1800. 2093. 75 0974. 1715. 1353. 85 0612. 0711. 0777.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2192. 2472. 2669. 55 2012. 2469. 2720. 65 1718. 2427. 2758. 75 1358. 2193. 1865. 85 843. 959. 1041.
G
P
F
Coffaire II:
Ceiling Type:
Lamp Quantity 2=2 Lamp 3=3 Lamp
Fits both Standard Grid
32=T8 (Nominal 48")
Ballast Type:
CY For NYC Code – I.B.E.W. Manufactured
CN For NYC Code – Local 3 Manufactured
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield – baked flat white acrylic enamel. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4 and CF4FK SPACER. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX: C.
Specifications Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .66. To reduce glare the average brightness at 65° shall not exceed 2093 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.6%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay. Finish: Chassis exterior – baked white post painted acrylic enamel. Cavity – baked white post painted acrylic enamel. Reflector – baked white post painted