1BHFPG Covelite™ -BNQ5QFS$SPTT4FDUJPO

Voltage Style Lamps Length
2 = 2-Lamp T5 2 = 2-Foot Nominal T5 = T5 Standard Output 3 = 3-Foot Nominal HO = T5 High Output 4 = 4-Foot Nominal 6 = 6-Foot Nominal 8 = 8-Foot Nominal
1 = 120v 2 = 277v
Features 1. Housing: Die-formed 20 gauge pre-painted steel.
Electrical 3 conductor, 12 gauge wire. Color-coded quick connectors allow ease of connection for joiner modules. For special circuiting, consult factory. Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off.
Fixture O.A. Length 2-foot nominal 22” (55.88cm) 3-foot nominal 34” (86.36cm) 4-foot nominal 46” (116.84cm) 6-foot nominal 68” (172.72cm) 8-foot nominal 92” (233.68cm)
Labels UL, cUL and I.B.E.W.
2.Lamping: Two T5 fluorescent lamps. Provided by others.
Fixture T5 T5HO 2-foot nominal 2-FP14 2-FP24/HO 3-foot nominal 2-FP21 2-FP39/HO 4-foot nominal 2-FP28 2-FP54/HO 6-foot nominal 4-FP21 4-FP39/HO 8-foot nominal 4-FP28 4-FP54/HO

"JSQPSU3PBE 'BMM3JWFS ."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #
Half Scale · Ballast

1BHFPG Covelite™ -BNQ5QFS$SPTT4FDUJPO
CANDLEPOWER Zone 0 22 45 67 90 112 135 157 180

Deg.

180 1399
175 1400 1395 1385 1392 1408 1429 1447 1449 1468
165 1562 1577 1536 1422 1367 1468 1525 1551 1566
155 1650 1644 1561 1439 1278 1432 1517 1559 1575
145 2018 1886 1556 1352 1143 1343 1453 1551 1588
135 2562 2410 1779 1243 967 1201 1379 1601 1680
125 2995 2720 2067 1121 755 1024 1349 1528 1523
115 3327 3229 2292 1170 524 846 1087 890 830
105 2256 2331 2106 1063 301 618 451 423 384
95 371 540 544 557 88 132 133 150 143
90
0
Zone Lumens Luminaire 0 - 90 0 0.0 0.0 90 - 180 7840 78.4 100.0 0 - 180 7840 78.4 100.0
Readings are rounded off based on initial footcandles at center of 20-foot run of luminaries. Room reflectance are 80% ceiling, 50% wall and 20% floor.
T5 54W, 2 Fixtures, 2 Rows, 2 Walls 14" (0.36) from Ceiling
T5 54W, 2 Fixtures, 2 Rows, 2 Walls 18" (0.46) from Ceiling
Distance from wall 2' 4' 6' 8' 10' 12' 14'
2' 4' 6' 8' 10' 12' 14'
18" (0.46m)
296 125 91 48 60 122 291
Distance From Ceiling Distance From Ceiling
8'6" (2.59m) 9'6" (2.90m) 10'6" (3.20m) 11'6" (3.51m) 12'6" (3.81m)
90 91 89 87 89 91 90 82 83 83 82 83 83 82 77 77 78 77 78 77 77 70 70 72 72 72 71 70 65 65 66 66 66 65 65
T5 54W, 1 Fixture, 1 Row, 1 Wall, 14" (0.36) from Ceiling
T5 54W, 1 Fixtures, 1 Row, 1 Wall, 18" (0.46) from Ceiling
2' 4' 6' 8' 10' 12' 14' 2' 4' 6' 8' 10' 12' 14'
18" (0.46m)
283 111 44 24 17 14 13
8'6" (2.59m) 9'6" (2.90m) 10'6" (3.20m) 11'6" (3.51m) 12'6" (3.81m)
62 60 53 44 36 31 28 54 53 48 41 35 30 28 49 48 44 38 34 30 27 44 43 40 36 32 28 27 39 39 37 33 30 27 25
Data is based on bare lamp photometrics. Dashed lines in beam spreads indicate narrow axes of oval shaped beams. FC is initial footcandles at center of beam. L and W are to the point that the candlepower drops 50% of maximum.