Ordering information

T5/T5HO PG = Electronic Linear
F = Internal Fusing (Canada) GLR = Internal Fusing (USA) FK92X4 = Drywall Kit for
T5/T5HO Program Start (
plaster frames EM* = TT5/T5/T5HO
Emergency Lighting System (USA) E* = T5/T5HO Emergency
Lighting System (Canada) QVS-HD = Alter Hold Down
Clips (Std 15/16" only)
OS = Open slot (no acrylic) lamp shield
OP = One piece (no center slot) lamp shield
*2x4 versions with double- switching are 5-1/4" deep while regular 2x4 versions (1 ballast) are 3-5/8" deep.
For Dimming Ballast Suffix, please consult your Lightolier Representative.
s3-lamp combination only available with one piece lamp shield
Finish Chassis exterior - phosphate undercoating, baked white acrylic matte high reflectance paint finish. Electrical Thermally protected class “P” ballast. If K.Os are within 3" of ballast use wire suitable for at least 90C. Suitable for damp location. Labels Listed by cCSAus.

Options · Type · Lamp Shield Details

Page 2 of 2 2' x 4' semi-recessed direct/indirect fluorescent
Performance
Candlepower
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 80 70 50 Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10
ZONE DEG ALONG 22.5 45 67.5 ACROSS 0 1172 5 1171 1171 1172 1168 1162 10 1152 1161 1160 1153 1156 15 1125 1137 1139 1138 1137 20 1095 1102 1105 1117 1116 25 1050 1056 1066 1081 1094 30 991 1007 1028 1045 1061 35 929 941 976 1000 1008 40 851 870 918 953 967 45 765 801 845 887 906 50 671 709 776 834 856 55 581 628 695 784 812 60 478 537 632 706 718 65 379 446 555 593 599 70 286 359 450 478 495 75 193 274 333 354 358 80 116 182 198 174 161 85 44 64 43 55 71 90 0 0 7 16 21
0 .85 .83 .79 .79 .79 1 .78 .75 .72 .69 .76 .73 .70 .68 .70 .68 .66 2 .71 .65 .60 .56 .69 .64 .59 .55 .61 .57 .54 3 .65 .57 .51 .47 .63 .56 .51 .46 .54 .49 .46 4 .59 .51 .44 .40 .58 .50 .44 .39 .48 .43 .39 5 .54 .45 .38 .33 .52 .44 .37 .33 .42 .37 .33 6 .49 .40 .33 .29 .48 .39 .33 .28 .38 .32 .28 7 .45 .36 .29 .25 .44 .35 .29 .25 .34 .28 .24 8 .42 .32 .26 .21 .41 .31 .25 .21 .30 .25 .21 9 .39 .29 .22 .18 .37 .28 .22 .18 .27 .22 .18 10 .36 .26 .20 .16 .35 .26 .20 .16 .25 .20 .16 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
0°
LUMINAIRE INPUT WATTS = 67.5
Report No: LSCD079 Cat. No: QCH2GPFOS228 2 28W T5 Fluorescent Lamps at 2600 lumens. Efficiency: 71.4% Candela at Nadir: 1172cd
ZONE LUMENS % LAMP % LUMINAIRE 0-30 925 17.80 24.92 0-40 1533 29.49 41.28 0-60 2807 53.98 75.57 0-90 3714 71.43 100.00 40-90 2181 41.94 58.72 60-90 907 17.45 24.43 90-180 0 .00 .00 0-180 3714 71.43 100.00
Candlepower
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 80 70 50 Wall Reflectance 70 50 30 10 70 50 30 10 50 30 10
ZONE DEG ALONG 22.5 45 67.5 ACROSS 0 1925 5 1921 1921 1920 1917 1917 10 1897 1903 1906 1902 1896 15 1848 1872 1868 1876 1875 20 1790 1808 1817 1831 1839 25 1723 1737 1752 1774 1790 30 1623 1649 1689 1716 1729 35 1514 1548 1594 1641 1658 40 1386 1426 1503 1560 1588 45 1247 1298 1387 1463 1494 50 1096 1156 1267 1358 1391 55 920 1003 1145 1249 1281 60 752 864 1011 1099 1131 65 592 709 864 953 971 70 439 570 702 779 802 75 300 431 528 594 601 80 177 275 336 323 304 85 68 101 76 102 110 90 0 0 15 33 38
0 .92 .90 .86 .86 .86 1 .84 .81 .78 .75 .82 .79 .76 .73 .76 .73 .71 2 .77 .71 .65 .61 .75 .69 .64 .60 .66 .62 .59 3 .70 .62 .56 .51 .68 .61 .55 .51 .59 .54 .50 4 .64 .55 .48 .43 .63 .54 .48 .43 .52 .46 .42 5 .59 .48 .41 .36 .57 .48 .41 .36 .46 .40 .36 6 .54 .43 .36 .31 .52 .42 .36 .31 .41 .35 .31 7 .49 .39 .32 .27 .48 .38 .32 .27 .37 .31 .27 8 .45 .35 .28 .23 .44 .34 .28 .23 .33 .27 .23 9 .42 .31 .25 .20 .41 .31 .24 .20 .30 .24 .20 10 .39 .28 .22 .18 .38 .28 .22 .18 .27 .21 .18 DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
0°
LUMINAIRE INPUT WATTS = 99.4
Report No: LSCD078 Cat. No: QCH2GPFOP328 3 28W T5 Fluorescent Lamps at 2600 lumens. Efficiency: 77.5% Candela at Nadir: 1925cd
ZONE LUMENS % LAMP % LUMINAIRE 0-30 1520 19.49 25.16 0-40 2515 32.25 41.62 0-60 4581 58.74 75.82 0-90 6042 77.47 100.00 40-90 3527 45.22 58.38 60-90 1461 18.73 24.18 90-180 0 .00 .00 0-180 6042 77.47 100.00
Room Cavity Ratio · Room Cavity Ratio