Page 1 of the Lightolier CS6132 user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Calculite ® Compact Fluorescent Surface Cylinder CS6132

Page 1 of 2 6" Aperture Triple Tube (4-Pin) Ceiling & Wall Mount

6 (959 mm)

10 1/4" (260 mm)

FACSA36 (Stem Kit)

6 1/2" (165 mm)

6 1/2" (165 mm)

CW6132 (Wall Mount)

Complete Fixture Ceiling Mount Complete Fixture Wall Mount

CS6132VUCCL Electronic, 120V - 277V CW6132VUCCL Electronic, 120V - 277V CS6132VJUM7CCL Advanced Mark VII Dim., 120V - 277V CW6132VJUM7CCL Advanced Mark VII Dim., 120V - 277V CS6132VJ1MXCCL Advanced Mark X Dim., 120V CW6132VJ1MXCCL Advanced Mark X Dim., 120V CS6132VJ2MXCCL Advanced Mark X Dim., 277V CW6132VJ2MXCCL Advanced Mark X Dim., 277V Finish Finish

Comfort Clear™ Reflector, White Housing Comfort Clear™ Reflector, White Housing Lamp Lamp

26 / 32W Triple Tube, 4 Pin 26 / 32W Triple Tube, 4 Pin

Features 1. Reflector: 16 ga. Alzak® aluminum, 50° visual cutoff to lamp and lamp image, medium distribution. Comfort Clear™low iridescence finish. 2. Housing: One piece 16 ga. spun aluminum with returned bottom edge to seat reflector; no visible hardware. Matte white baked enamel finish. 3. Ballast: Mounted on support bracket, can be easily removed for service. 4. Socket Bracket: Snaps onto reflector neck to assure consistently correct optical alignment. 5. Retaining Springs: Precision-tooled steel friction springs secure reflector to housing for quick, tool-less installation. 6. Stem Kit: Cat. No. FA CSA36: Provided with 1/2" dia. stem and 5 1/2" dia. canopy. Self aligning swivel provides maximum 38° vertical adjustment. Installs over 4" octagonal outlet box. Stem can be cut to length on site. Matte white baked enamel finish. 7. Crossbar: Installs over 3" or 4" octagonal or rectangular outlet box. 8. Cleat: Cast aluminum; allows mounting to mullion or post without backplate. 9. Backplate: Die-cast aluminum; 6 1/4" high by 4" wide; matte white. 10.Bracket: Extruded aluminum; matte white finish. Secured to cleat by set screws.

Options and Accessories Other Reflector and Housing Finishes Consult factory Fuse (Slow Blow) Add Suffix F (non-dim. only, all others consult factory)

Labels UL listed for damp locations, I.B.E.W.

Alzak® is a registered trademark of ALCOA. US Patent Pending.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Electrical Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • C0704

UL listed for 90°C supply conductors.

Show 4 more labels / short text on this page
37 3/4" · 6" · (153 mm) · 3/8" (10 mm)
Page 2 of the Lightolier CS6132 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Calculite ® Compact Fluorescent Surface Cylinder CS6132

Page 2 of 2 6" Aperture Triple Tube (4-Pin) Ceiling & Wall Mount

26W 32W Spacing Ratio = 1.0 Spacing Ratio = 1.1

Report No: LSI 14025 Lightolier Recessed Fluorescent Luminaire, With Comfort Clear™ Reflector One 26 Watt CPFL GE Lamp, Cat# F26TBX/SPX35-835. Lumen Rating = 1800 Lms.

Report Prepared For: Lightolier 04-27-1999 Report No: LRL 499-9G Lamps: 1 PLT-32 Lumens: 2400 Descrip.: 6" Dia X 10" Ht Recessed Downlight With Comfort Clear™ Reflector. Vertical Lamp.

Lightolier CS6132 — 26W 32W Spacing Ratio = 1.0 Spacing Ratio = 1.1 diagram (page 2)
図 1 · 26W 32W Spacing Ratio = 1.0 Spacing Ratio = 1.1

ZONAL SUMMARY ANGLE CP LUMENS 0 775 5 806 77 10 780 15 708 199 20 646 25 566 258 30 478 35 402 245 40 285 45 78 81 50 13 55 4 4 60 2 65 1 2 70 1 75 1 1 80 0 85 0 0 90 0

ZONAL SUMMARY ZONE AVG* ZONAL DEG. C.P. LUMENS 180 0 175 0 0 165 0 0 155 0 0 145 0 0 135 0 0 125 0 0 115 0 0 105 0 0 95 0 0 90 0 0 85 1 1 75 1 1 65 3 3 55 9 8 45 99 77 35 563 354 25 904 418 15 1063 301 5 1066 102 0 1035

25° 15° 5° 0°

**Efficiency=52.7%** Date: 4-27-99 CIE Type Direct Luminous Diameter: 6.000 This Report Based On LM-1 And Other Pertinent IES Procedures.

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS %LAMP %LUMINAIRE 0-30 533 29.66 61.66 0-40 778 43.25 89.92 0-60 863 47.98 99.75 0-90 865 48.10 100.00 40-90 87 4.85 10.08 60-90 2 .12 .25 90-180 0 .00 .00 0-180 865 48.10 100.00

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0–30 821 34.2 64.9 0–40 1175 49.0 92.9 0–60 1260 52.5 99.6 0–90 1265 52.7 100.0 40–90 90 3.8 7.1 60–90 5 0.2 0.4 90–120 0 0.0 0.0 90–150 0 0.0 0.0 90–180 0 0.0 0.0 0–180 1265 52.7 100.0

**Efficiency=48.1%** Date: 4-23-99 CIE Type Direct Luminous Diameter: 6.000 This Report Based On LM-1 And Other Pertinent IES Procedures.

Coefficients of Utilization Coefficients of Utilization

Effective Floor Cavity Reflectance = .20

Effective Floor Cavity Reflectance = .20

80 70 50 30 10

80 70 50 30 10

50 30 10Wall Reflectance50 30 10 50 30 1050 30 1050 30 10 .54 .53 .52 . .50 .49 .47 . .47 .45 .44 . .45 .42 .40 . .42 .39 .37 . .40 .37 .35 . .37 .34 .33 . .35 .32 .30 . .33 .30 .28 . .31 .28 .26 .53 .52 .51 50 .48 .47 47 .45 .43 44 .42 .40 42 .39 .37 39 .37 .35 37 .34 .32 34 .32 .30 32 .30 .28 30 .28 .26.51 .50 .49 .48 .47 .46 .46 .44 .43 .43 .41 .40 .41 .39 .37 .39 .36 .35 .36 .34 .32 .34 .32 .30 .32 .30 .28 .30 .28 .26.49 .48 .48 .47 .46 .45 .44 .43 .42 .42 .41 .39 .40 .38 .37 .38 .36 .34 .36 .34 .32 .34 .31 .30 .32 .29 .28 .30 .27 .26.47 .47 .46 .45 .45 .44 .43 .42 .41 .41 .40 .39 .39 .38 .36 .37 .36 .34 .35 .33 .32 .33 .31 .30 .31 .29 .28 .29 .27 .26
50 30 10Wall Reflectance50 30 10 50 30 1050 30 1050 30 10 .59 .58 .57 .56 .54 .53 .53 .51 .50 .51 .48 .47 .48 .46 .44 .46 .43 .42 .44 .41 .39 .41 .39 .37 .39 .36 .35 .35 .32 .31.58 .57 .56 .55 .54 .52 .53 .51 .49 .50 .48 .46 .48 .45 .44 .46 .43 .41 .43 .41 .39 .41 .39 .37 .39 .36 .35 .35 .32 .31.56 .55 .54 .54 .52 .51 .51 .50 .49 .49 .47 .46 .47 .45 .43 .45 .43 .41 .43 .41 .39 .41 .38 .37 .38 .36 .35 .35 .32 .30.54 .53 .53 .52 .51 .50 .50 .49 .48 .48 .46 .45 .46 .44 .43 .44 .42 .41 .42 .40 .39 .40 .38 .37 .38 .36 .34 .34 .32 .30.52 .52 .51 .51 .50 .49 .49 .48 .47 .47 .46 .45 .45 .44 .43 .44 .42 .41 .42 .40 .39 .40 .38 .36 .38 .36 .34 .34 .32 .30

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • C0704
Show 8 more labels / short text on this page
85° · 75° · 65° · 55° · 45° · 35° · Room Cavity Ratio · Room Cavity Ratio
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier CS6132について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier CS6132に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier CS6132 取扱説明書(PDF)

2 ページ·92 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…