JA
Lightolier logo
公式取扱説明書

Lightolier D01-CFL

3 ページ·461 KB·インテリア家具・調度品·PDF·EN
Lightolier D01-CFL
目次 11セクション Architectural Decorative Vetro Downlight D01 · Page 1 of 3 Compact Fluorescent · Labels cULus (Damp Location) · Lightolier is a Philips group brand · … 表示非表示
Page 1 of the Lightolier D01-CFL user manual — Lightolier is a Philips group brand
1ページ · クリックして拡大
1ページ

Architectural Decorative Vetro Downlight D01

Page 1 of 3 Compact Fluorescent

Lightolier D01-CFL — Architectural Decorative Vetro Downlight D01 diagram (page 1)
図 1 · Architectural Decorative Vetro Downlight D01
Lightolier D01-CFL — Architectural Decorative Vetro Downlight D01 diagram (page 1)
図 2 · Architectural Decorative Vetro Downlight D01

Complete Fixture consists of Decorative Element, Trim-Kit + Frame-In Kit. Each sold seperately. 3 Piece Ordering System, Example: D4A01 + 8011CL + 4118VU

Decorative Element Trim Catalog No.- KitFrame-In Kit LampingDimensions ABC D4A01 8011CL4118VU Family (1) 18 D4132VU Family (1) 26W Triple Tube W or 32W Triple Tube3 3/4"6"1 3/4" D6A01 8021C 8052C 8051CL; 8031CL; 8091DCL L LS6132BU Family (1) 26 6213HU Family (2) 13 6218HU Family (2) 18W or 32W Triple Tube W Quad W Quad4 5/8"7 1/2"1 7/8" D7A01 8022C 8056C 8056C 8056CL; 8037CL; 8097DCL L; 8096DCL L; 8096DCL LS7142BU Family (1) 26 7218HU Family (2) 18 S7226HU Family (2) 26 7126HU Family (1) 26W, 32W or 42W Triple Tube W Quad Tube W Quad Tube W Quad Tube5 1/2"9"2"
Lightolier D01-CFL — Architectural Decorative Vetro Downlight D01 diagram (page 1)
図 3 · Architectural Decorative Vetro Downlight D01

Features 1. Decorative Element: Solid high temp, UV resistant composite with open aperture. Interior diameter is frosted. Polished exterior. 2. Aluminum Insert: Satin Aluminum ring is mechanically inserted in composite to create drama and intrigue in the element. 3. Die Cast Construction Ring: Exterior edge of construction ring is visible, satin aluminum finish matches diameter of decorative element for a flangeless appearance. 4. Fastener cover: Stamped aluminum cover ring provided on top of decorative element to cover construction ring fasteners. 5. Mounting Frame Fasteners: Four #8-32 screws and 4 knurled die-cast thumb screws secure construction ring to frame in kit. 6. Reflector: FLANGELESS TRIM REQUIRED. Specified separately. Use Specular Clear (CL) finish for best performance and aesthetics 7. Frame-In Kit: Specified separately. See Trim Specification Sheet for additional details.

Mechanical Decorative elements securely fastened to four mounting frame studs.

Labels cULus (Damp Location)

Lightolier D01-CFL — Labels cULus (Damp Location) diagram (page 1)
図 4 · Labels cULus (Damp Location)
  • 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 Philips Group
  • B1108

Lightolier is a Philips group brand

Page 2 of the Lightolier D01-CFL user manual — Lightolier is a Philips group brand
2ページ · クリックして拡大
2ページ

Architectural Decorative Vetro Downlight D01

Page 2 of 3 Compact Fluorescent

8021CL-D6AO1

Calculite 6" Recessed Vetro Downlight, Cat.# 8021CL/D6A01

Lightolier D01-CFL — Architectural Decorative Vetro Downlight D01 diagram (page 2)
図 5 · Architectural Decorative Vetro Downlight D01

32W G.E. Biax T/E Triple Tube (Lower Position). Lumen Rating = 2200 Lms. Universal Ballast #C2642UNVBES

Ceiling80%70%50%30%10% Wall70 50 30 1070 50 30 1050 30 1050 30 1050 30 10 0 RCRZonal Cavity Method - Effective Floor Reflectance = 20% 0 1 2 3 Ratio 4 Cavity 5 6 Room 7 8 9 10.50 .47 .46 .44 .43 .44 .42 .40 .38 .41 .38 .36 .34 .39 .35 .33 .30 .37 .33 .30 .28 .35 .30 .27 .25 .32 .28 .25 .23 .30 .26 .23 .21 .28 .24 .21 .19 .27 .22 .19 .17.49 .46 .45 .43 .42 .43 .41 .39 .37 .40 .37 .35 .33 .38 .35 .32 .30 .36 .32 .29 .27 .34 .30 .27 .25 .32 .27 .25 .23 .30 .25 .23 .21 .28 .23 .21 .19 .26 .22 .19 .17.46 .46 .46 .42 .42 .41 .39 .38 .36 .36 .34 .33 .34 .31 .30 .31 .29 .27 .29 .26 .25 .27 .24 .22 .25 .22 .20 .23 .20 .19 .21 .19 .17.44 .44 .44 .41 .40 .39 .38 .36 .35 .35 .33 .32 .33 .31 .29 .30 .28 .27 .28 .26 .24 .26 .24 .22 .24 .22 .20 .22 .20 .18 .21 .18 .17.42 .42 .42 .41 .39 .38 .38 .37 .36 .35 .34 .34 .34 .33 .31 .31 .32 .30 .29 .28 .29 .28 .26 .26 .27 .26 .24 .23 .25 .23 .22 .21 .24 .22 .20 .19 .22 .20 .18 .18 .20 .18 .17 .16

Angle Mean CP LMS. Angle Mean CP LMS. 0 459 90 20 5 448 44 95 17 15 10 489 100 3 15 526 146 105 2 2 20 524 110 2 25 487 223 115 2 2 30 426 120 2 35 356 222 125 2 2 40 274 130 2 45 178 138 135 2 1 50 85 140 2 55 45 48 145 2 1 60 39 150 2 65 34 34 155 2 1 70 31 160 2 75 27 29 165 2 1 80 24 170 2 85 22 24 175 2 0 90 20 180 2

Luminaire Input Watts = 33.0

Zonal Lumens and Percentages

Zone Lumens % Lamp %Luminaire 0-30 413 18.77 44.29 0-40 634 28.84 68.05 0-60 820 37.32 88.03 0-90 907 41.26 97.35 40-90 273 12.42 29.30 60-90 86 3.95 9.31 90-180 24 1.12 2.65 0-180 932 42.39 100.00 ** Efficiency = 42.4% **

Certified test report# 3494FR Computed by LSI program **TEST-LITE** SC = 1.0

Luminance Summary - CD. / SQ. M. Angle Mean CD/SQ M 45 13825 55 4359 65 4460 75 5694 85 13872

Tested According to IES Procedures. Test Distance Exceeds Five

Prepared ForLightolier Fall River, MA

Times the Greatest Luminous Opening of Luminaire.

8031CL-D6AO1

Calculite 6" Dia. Recessed Horizontal Vetro Downlight,

Lightolier D01-CFL — 8031CL-D6AO1 diagram (page 2)
図 6

Cat.# 8031CL/D6A01 32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS. Universal Ballast #C2642UNVBES(#1)

Ceiling80%70%50%30%10% Wall70503010705030105030105030105030100 RCRZonal Cavity Method - Effective Floor Reflectance = 20% 0 1 2 3 Ratio 4 Cavity 5 6 Room 7 8 9 10.44 .41 .40 .39 .37 .39 .36 .34 .33 .36 .33 .31 .29 .34 .30 .28 .26 .32 .28 .25 .23 .30 .26 .23 .21 .27 .23 .21 .19 .26 .21 .19 .17 .24 .20 .17 .15 .22 .18 .15 .14.43 .40 .39 .38 .37 .38 .36 .34 .32 .35 .32 .30 .29 .33 .30 .28 .26 .31 .27 .25 .23 .29 .25 .23 .21 .27 .23 .20 .19 .25 .21 .19 .17 .23 .19 .17 .15 .22 .18 .15 .13.41 .41 .41 .37 .37 .36 .34 .33 .32 .31 .30 .28 .29 .27 .25 .27 .24 .23 .25 .22 .21 .22 .20 .18 .21 .18 .17 .19 .17 .15 .17 .15 .13.40 .40 .40 .36 .35 .35 .33 .32 .31 .31 .29 .28 .28 .26 .25 .26 .24 .23 .24 .22 .20 .22 .20 .18 .20 .18 .17 .19 .16 .15 .17 .15 .13.38 .38 .38 .37 .35 .34 .34 .33 .32 .31 .30 .30 .30 .28 .27 .27 .27 .26 .25 .24 .25 .24 .22 .22 .23 .22 .20 .20 .22 .20 .18 .18 .20 .18 .16 .16 .18 .16 .15 .14 .17 .15 .13 .13

Angle Along 22.5 45 67.5 Across LMS 0 408 5 410 418 423 422 420 40 10 432 445 452 440 436 15 445 446 439 429 431 123 20 434 427 416 409 413 25 419 393 393 417 416 187 30 384 388 381 391 388 35 326 351 383 396 393 224 40 252 266 299 322 323 45 193 182 174 172 171 150 50 150 141 127 111 111 55 87 79 73 72 73 72 60 41 42 43 44 44 65 36 37 37 38 38 38 70 32 33 33 34 34 75 28 28 29 30 30 31 80 25 26 27 27 26 85 23 24 24 25 24 26 90 20 21

Luminaire Input Watts = 36.0

Zonal Lumens and Percentages

Zone Lumens % Lamp %Luminaire 0-30 350 14.60 39.31 0-40 574 23.92 64.42 0-60 796 33.19 89.37 0-90 891 37.14 100.00 40-90 317 13.22 35.58 60-90 94 3.95 10.63 90-180 0 .00 .00 0-180 891 37.14 100.00 ** Efficiency = 37.1% **

Certified test report no. 3533FR Computed by LSI program **TEST-LITE** SC(Along) = 1.3, SC(Across) = 1.5

Prepared ForLightolier Fall River, MA

Tested According to IES Procedures. Test Distance Exceeds Five

Times the Greatest Luminous Opening of Luminaire.

Job Information Type:

  • 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 Philips Group
  • B1108

Lightolier is a Philips group brand

Show 10 more labels / short text on this page
90° · Coefficients of Utilization · Candlepower Summary · 60° · 30° · 0° · 90° · Coefficients of Utilization · Candlepower Summary · 0°
Page 3 of the Lightolier D01-CFL user manual — Lightolier is a Philips group brand
3ページ · クリックして拡大
3ページ

Architectural Decorative Vetro Downlight D01

Page 3 of 3 Compact Fluorescent

8011CL-D4AO1

Calculite 4” Vetro Downlight, Cat.# 8011Cl D4A01 18W G.E. Biax T/E triple Tube. Lumen Rating = 1200 LMS. Universal Ballast #C218UNVBES

Lightolier D01-CFL — Architectural Decorative Vetro Downlight D01 diagram (page 3)
図 7 · Architectural Decorative Vetro Downlight D01
Ceiling80%70%50%30%10% Wall70503010705030105030105030105030100 RCRZonal Cavity Method - Effective Floor Cavity Reflectance = 20% 0 1 2 3 Ratio 4 Cavity 5 6 Room 7 8 9 10.41 .39 .37 .36 .35 .36 .34 .33 .32 .34 .32 .30 .28 .32 .30 .27 .26 .31 .27 .25 .24 .29 .26 .23 .22 .27 .24 .21 .20 .26 .22 .20 .18 .24 .20 .18 .17 .23 .19 .17 .15.40 .38 .37 .36 .35 .36 .34 .32 .31 .34 .31 .30 .28 .32 .29 .27 .26 .30 .27 .25 .23 .28 .25 .23 .22 .27 .23 .21 .20 .25 .22 .20 .18 .24 .20 .18 .17 .22 .19 .17 .15.38 .38 .38 .35 .34 .34 .33 .32 .30 .30 .29 .28 .28 .27 .25 .26 .25 .23 .25 .23 .21 .23 .21 .20 .21 .19 .18 .20 .18 .16 .18 .16 .15.36 .36 .36 .34 .33 .33 .32 .31 .30 .30 .28 .27 .28 .26 .25 .26 .24 .23 .24 .23 .21 .22 .21 .19 .21 .19 .18 .20 .18 .16 .18 .16 .15.35 .35 .35 .34 .33 .32 .32 .31 .31 .30 .29 .29 .29 .28 .27 .26 .27 .26 .25 .24 .25 .24 .23 .22 .24 .22 .21 .21 .22 .21 .19 .19 .21 .19 .18 .17 .19 .18 .16 .16 .18 .16 .15 .14

Angle Mean CP Lumens 0 244 5 239 23 10 254 15 263 73 20 255 25 233 107 30 204 35 174 107 40 131 45 56 51 50 21 55 17 16 60 15 65 13 13 70 12 75 10 11 80 9 85 9 10 90 8

Luminaire Input Watts = 23.0

Zonal Lumens and Percentages

Zone Lumens % Lamp %Luminaire 0-30 203 16.97 49.50 0-40 311 25.92 75.59 0-60 377 31.49 91.85 0-90 411 34.29 100.00 40-90 100 8.37 24.41 60-90 33 2.79 8.15 90-180 0 .00 .00 0-180 411 34.29 100.00 ** Efficiency = 34.3% **

SC(Along) = 1.3, SC(Across) = 1.5

Certified test report no. 3557FR Computed by LSI program **TEST-LITE** SC = 1.2

Tested According to IES Procedures. Test Distance Exceeds Five

Times the Greatest Luminous Opening of Luminaire.

Prepared ForLightolier Fall River, MA

8091CL-D6AO1

Calculite 6" Vetro Downlight, Cat.# 8091CL/D6A01 Opal Lens 32W Sylvania Dulux T/E Triple Tube. Lumen Rating = 2400 LMS. Universal Ballast #C2642UNVBES(#1)

Ceiling80%70%50%30%10% Wall70503010705030105030105030105030100 RCRZonal Cavity Method - Effective Floor Reflectance = 20% 0 1 2 3 Ratio 4 Cavity 5 6 Room 7 8 9 10.36 .33 .32 .31 .30 .31 .29 .28 .26 .29 .27 .25 .23 .27 .25 .22 .21 .26 .23 .20 .19 .24 .21 .19 .17 .22 .19 .17 .15 .21 .18 .15 .14 .20 .16 .14 .13 .18 .15 .13 .11.35 .33 .32 .31 .30 .30 .29 .27 .26 .28 .26 .24 .23 .27 .24 .22 .21 .25 .22 .20 .19 .23 .20 .18 .17 .22 .19 .17 .15 .21 .17 .15 .14 .19 .16 .14 .13 .18 .15 .13 .11.33 .33 .33 .30 .29 .29 .28 .26 .25 .25 .24 .23 .23 .22 .20 .22 .20 .18 .20 .18 .17 .18 .16 .15 .17 .15 .14 .16 .14 .13 .15 .13 .11.32 .32 .32 .29 .28 .28 .27 .26 .25 .25 .23 .22 .23 .21 .20 .21 .20 .18 .20 .18 .17 .18 .16 .15 .17 .15 .14 .15 .14 .12 .14 .13 .11.31 .31 .31 .30 .28 .28 .27 .26 .26 .25 .24 .24 .24 .23 .22 .21 .22 .21 .20 .19 .21 .19 .18 .18 .19 .18 .17 .16 .18 .16 .15 .14 .16 .15 .14 .13 .15 .14 .12 .12 .14 .12 .11 .11

Angle Along 22.5 45 67.5 Across LMS 0 460 5 447 447 448 449 448 43 10 425 425 426 428 428 15 393 394 396 398 398 112 20 356 357 360 363 364 25 316 317 320 325 327 148 30 274 275 278 284 288 35 231 232 237 245 251 150 40 188 189 194 204 207 45 148 149 152 158 160 119 50 111 111 111 112 113 55 50 50 51 53 54 58 60 42 42 43 44 44 65 36 37 37 37 38 37 70 32 32 32 33 33 75 28 30 80 25 85 23 25 90 20 20 20 21 20

Luminaire Input Watts = 38.0

Zonal Lumens and Percentages

Zone Lumens % Lamp %Luminaire 0-30 302 12.61 41.97 0-40 452 18.84 62.73 0-60 629 26.21 87.25 0-90 721 30.04 100.00 40-90 268 11.20 37.27 60-90 91 3.83 12.75 90-180 0 .00 .00 0-180 721 30.04 100.00 ** Efficiency = 30.0% **

Certified test report no. 3517FR Computed by LSI program **TEST-LITE** SC = 1.0

Prepared ForLightolier Fall River, MA

Tested According to IES Procedures. Test Distance Exceeds Five

Times the Greatest Luminous Opening of Luminaire.

Job Information Type:

  • 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 Philips Group
  • B1108

Lightolier is a Philips group brand

Show 9 more labels / short text on this page
90° · Coefficients of Utilization · 0° · 90° · Coefficients of Utilization · Candlepower Summary · 60° · 30° · 0°
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier D01-CFLについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier D01-CFLに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier D01-CFL 取扱説明書(PDF)

3 ページ·461 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…