Page 1 of 2 2' x 4' Recessed Fluorescent, 3", 32 Cell, Parabolic Louver Static or Air Supply/Return, 4 Lamp, T8 or T5

G
exposed T-grid ceiling. T
exposed slot T-grid ceiling.



1/4" max.
1-1/2" max. 1-7/8" max.
15/16" or 1" 24"
6" (152mm) Air supply slots (DPA only)
2" x 2-1/2" access plate with two K.O.s (7/8" dia.)

concealed Z-spline ceiling. F
plaster ceiling/flanged.


Plaster Opening 24-1/8" 1-1/8" min. 3-3/4" max.
1-1/8" min. 3-3/4" max.
drywall kit.

Job Name:
Drywall Kit (See Options)
Cat. No.:
Lamp(s):
Volts/Ballast:
Order Catalog Number: FK92X4.

Page 2 of 2 2' x 4' Recessed Fluorescent, 3", 32 Cell Parabolic Louver Static or Air/Return, 4 Lamp, T8 or T5
Photometry Model No. DPA2G32LS432120O4 LER = FP - 56.7 IW - 110.9 BF - 0.86 Comparative yearly lighting energy cost per 1000 lumens = $4.23

coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 71 69 67 65 63 62 63 61 60 2 66 62 58 59 56 54 57 54 52 3 61 56 51 53 49 47 51 48 46 4 57 50 45 48 44 41 46 43 40 5 52 45 40 43 39 36 42 38 36 6 49 41 36 39 35 32 38 35 32 7 45 37 32 36 32 29 35 31 28 8 42 34 29 33 29 26 32 28 26 9 40 32 27 31 26 23 30 26 23 10 37 29 24 28 24 21 28 24 21 visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 82 76 71 76 81 76 73 79 20 30 84 79 74 71 83 78 74 71 20 40 85 81 77 73 85 80 77 73 20 60 87 82 79 76 86 82 79 75 30 20 85 80 73 75 85 80 74 77 30 30 87 82 75 71 86 82 75 70 30 40 88 83 78 73 87 83 78 72 30 60 89 85 80 75 88 85 80 74 30 80 89 86 82 77 89 86 81 76 40 20 86 82 77 76 86 82 78 78 40 30 88 84 78 72 87 84 78 72 40 40 89 85 81 74 88 85 80 73 40 60 89 86 82 76 89 86 82 75 40 80 90 87 83 78 90 87 83 77 40 100 91 88 85 79 90 88 84 79 60 30 88 84 80 74 88 84 80 74 60 40 89 86 82 76 89 86 82 75 60 60 90 87 83 78 90 87 83 77 60 80 91 88 84 79 90 88 84 79 60 100 91 88 85 81 91 89 85 80 100 40 89 86 83 78 89 86 83 77 100 60 90 87 84 80 90 87 84 79 100 80 91 88 86 81 91 88 85 80 100 100 91 89 87 83 91 89 86 82
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
S
Cells: 12=2 rows of 6 18=3 rows of 6 32=4 rows of 8
(lay-in T bar) F= Flanged (over
iridescence Semi-specular (standard) P =Low
lap) Z spline and plaster frame T= Slot grid or
Lamp Type/ Fixture Length:
Ballast Type:
iridescence Specular W =White Baked
two-directional concealed T (see options)
32=32W T8 28=28W T5 54=54W T5 (Nominal 48")
ND For NYC Code – Local 3 Manufactured
Options/Accessories Plaster Frame: Catalog Number: PF24. Continuous Row Installation: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: 2FC TRIM CSP (each joint). Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast; SUFFIX: B. Electrical Wiring Options: Consult factory. Air Closure Strip: SUFFIX: ACS4 (factory installed). Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A). Chicago Plenum: SUFFIX: CP.
Specifications (continued) Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi- specular anodized vertical grain aliminum reflector sheet is standard. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W. UL and ULc Listed.
Specifications Performance: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .69. To prevent glare the VCP shall be not less than 83 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 1138 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 63.9%. Air Handling (DPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal.