Page 1 of 2 2' x 2' Recessed Fluorescent, 3", 9 Cell Parabolic Louver Static or Air Supply/Return, 3 Lamp 1-5/8"U T8 or 2' Lamp T8


exposed T-grid ceiling. T
exposed slot T-grid ceiling.


1/4" max.

1-1/2" max. 1-7/8" max.
15/16" or 1" 24"
concealed Z-spline ceiling. F
plaster ceiling/flanged.
Air supply slots (DPA only)



Plaster Opening 24-1/8" 1-1/8" min. 3-3/4" max.
1-1/8" min. 3-3/4" max.
drywall kit.
2"x 2-1/2" access plate with two K.O.s (7/8" dia.)

Job Name:
Drywall Kit (See Options)
Cat. No.:
Lamp(s):
Volts/Ballast:
Order Catalog Number: FK92X2.

Page 2 of 2 2' x 2' Recessed Fluorescent, 3", 9 Cell Parabolic Louver Static or Air/Return, 3 Lamp 1-5/8"U T8 or 2' Lamp T8
Photometry Model No. DPA2G9LP32U120O3 LER = FP - 56.2 IW - 57.2 BF - 0.87 Comparative yearly lighting energy cost per 1000 lumens = $4.27
coefficients of utilization — zonal cavity method

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 71 68 66 64 63 61 62 61 59 2 65 61 58 58 55 53 56 54 52 3 60 55 51 52 49 46 50 48 45 4 56 49 45 47 43 40 46 42 40 5 52 45 39 43 38 35 41 38 35 6 48 40 35 39 34 31 38 34 31 7 45 37 32 35 31 28 34 31 28 8 42 34 29 32 28 25 32 28 25 9 39 31 26 30 26 23 29 25 23 10 36 29 24 28 24 21 27 23 21 visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
G00060 DPA2G9LP32U120O3 3 FBO31 / 41K, EACH RATED 2725 LUMENS. 2X2 TROFFER WITH 3X3 LI-SEMI-SPECULAR 9 CELL LOUVER.
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 67 60 55 62 70 65 62 61 20 30 70 64 56 53 73 68 62 58 20 40 73 67 60 55 76 70 65 60 20 60 75 69 63 59 77 72 68 63 30 20 72 66 58 61 75 69 63 61 30 30 75 68 59 53 77 71 63 58 30 40 77 71 63 56 79 73 67 60 30 60 78 73 66 59 80 75 69 63 30 80 80 75 68 62 81 77 71 65 40 20 75 69 63 63 78 72 67 62 40 30 77 71 63 56 79 74 67 59 40 40 79 73 66 58 81 76 69 61 40 60 80 75 69 61 82 77 72 63 40 80 82 77 71 63 83 79 73 66 40 100 83 78 73 66 84 80 75 68 60 30 79 74 67 59 81 76 70 62 60 40 80 76 69 61 82 78 72 63 60 60 82 77 71 63 83 79 74 66 60 80 83 79 73 66 84 80 75 68 60 100 83 80 75 68 85 81 77 70 100 40 81 77 72 65 83 79 74 67 100 60 82 78 74 67 84 80 76 69 100 80 84 80 75 69 85 81 78 71 100 100 84 81 77 71 86 82 79 73
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
P
Lamp Type/ Fixture Length: 2U= T8 1-5/8"U Lamp 17 = T8 2' Lamp (Nominal 24") Note: For Linear T5 Lamp option,
(lay-in T bar) F= Flanged (over
iridescence Semi-specular (standard) P =Low
lap) Z spline and plaster frame T= Slot grid or
Ballast Type:
iridescence Specular W =White Baked
two-directional concealed T (see options)
ND For NYC Code – Local 3 Manufactured
Options/Accessories Plaster Frame: Catalog Number: PF22. Continuous Row Installation: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: 2FC TRIM CSP (each joint). Radio Interference Filter: To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast; SUFFIX: B. Electrical Wiring Options: Consult factory. Air Closure Strip: SUFFIX: ACS2 (factory installed). Drywall Kit: Order Catalog Number: FK92X2. (Request Folio OA30-10 Rev. A). Chicago Plenum: SUFFIX: CP.
Specifications (continued) Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi- specular anodized vertical grain aliminum reflector sheet is standard. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with- in 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W. UL and ULc Listed.
Specifications Performance: In an installation of 3 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .68. To prevent glare the VCP shall be not less than 82 either lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2311 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 64.8%. Air Handling (DPA only) side air passages for air supply or air return. Supply air is discharged vertically. Optional side closure strips. Air return is also provided through the lamp compartment through fixture body ends. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Louver is pre-anodized aluminum (Coilzak® or equal.