Page 1 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 12 CELL PARABOLIC LOUVER, 2 LAMP T8 OR T12

DIMENSIONS


2-11/16" (68mm)
24" (610mm)
4" (102mm) 9/32" mounting hole 3/16" x 5/8" K.O.

7/8" dia. K.O. within 1-7/8" dia. K.O.

Job Information Type:
Job Name:
Stem mounting (four per fixture is required)
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 12 CELL PARABOLIC LOUVER, 2 LAMP T8 OR T12
coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 83 80 78 76 74 72 73 71 70 2 77 72 68 68 65 62 66 63 61 3 71 64 59 61 57 54 59 56 53 4 65 57 51 55 50 46 53 49 46 5 60 51 45 48 43 39 47 42 39 6 55 45 39 43 38 34 42 37 34 7 50 40 34 39 33 29 37 33 29 8 46 36 29 34 29 25 33 28 25 9 42 32 25 30 25 21 30 25 21 10 39 29 23 27 22 18 27 22 18 visual comfort probability


room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 77 74 75 85 73 70 72 75 20 30 80 77 72 75 77 73 68 71 20 40 83 80 76 75 80 76 71 69 20 60 83 81 79 78 82 79 75 72 30 20 81 76 75 81 78 74 73 74 30 30 83 79 73 72 81 76 69 70 30 40 85 81 76 72 84 79 72 67 30 60 85 81 79 75 85 81 75 71 30 80 85 82 81 77 85 81 77 73 40 20 81 80 77 81 78 77 76 75 40 30 84 82 75 72 82 79 72 70 40 40 86 84 78 72 84 81 74 68 40 60 86 84 80 75 85 83 77 71 40 80 86 84 82 77 85 83 79 74 40 100 86 84 82 77 85 83 79 74 60 30 84 83 77 74 82 80 74 72 60 40 86 85 80 74 84 82 76 70 60 60 86 85 82 76 85 84 79 73 60 80 86 85 83 78 85 84 81 75 60 100 86 85 83 78 85 84 81 75 100 40 86 85 80 76 84 82 77 72 100 60 86 85 82 78 85 84 79 75 100 80 86 85 83 80 86 84 81 78 100 100 86 85 83 81 86 84 81 78
DP
B
S
S
FIXTURE
NUMBER OF
BALLAST
LAMP QUANTITY:
VOLTAGE:
CELLS
COVER
BALLAST TYPE: 1-2 Lamp Mag. T12 LE
CEILING
(standard) P= Low-iridescence specular W=White Paint
32=T88 34=T12 (Nominal 48")
*Consult factory for availability of louver finishes.
OPTIONS & ACCESSORIES STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24") FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory.
SPECIFICATIONS (CONTINUED): LOUVER: pre-anodized aluminum (Coilzak® or equal). STANDARD FINISH: Louver—low iridescence, semi-specular pre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
SPECIFICATIONS: PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80. To prevent glare the VCP shall be not less than 85 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 476 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 73%. MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud- welded for rigidity with all seams finished smooth.