JA
Lightolier logo
公式取扱説明書

Lightolier DPB2S12LS232

2 ページ·289 KB·インテリア家具・調度品·PDF·EN
Lightolier DPB2S12LS232
目次 24セクション DEEPCELL SURFACE DPB2S12LS232 · LOUVER CONFIGURATION · DIMENSIONS · 5-1/2" (140mm) · … 表示非表示
Page 1 of the Lightolier DPB2S12LS232 user manual — 48" (1219mm)
1ページ · クリックして拡大
1ページ

DEEPCELL SURFACE DPB2S12LS232

Page 1 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 12 CELL PARABOLIC LOUVER, 2 LAMP T8 OR T12

  • Features
  • Only 5-1/2" deep.
  • 20 gauge steel body.
  • 45° mitered corners (body and louver).
  • Side-mounted ballast for cooler operation.
  • Coilzak ® aluminum parabolic louver.
  • Vertical grain on louver eliminates reflected lamp images on cross baffle.
  • Perfectly uniform four-side black reveal.
  • Spring-loaded “roosterhead” latches.
  • Reversible louver hinging.
  • Door jamb with integral positive light stop.
  • Flush end K.O.s for smooth surface appearance (at end of row or individual).
  • Protective film dust guard.
  • Louver interchangeable with Prismalyte (PNB)
  • Meets NYC Code requirements.
Lightolier DPB2S12LS232 — DEEPCELL SURFACE DPB2S12LS232 diagram (page 1)
図 1

LOUVER CONFIGURATION

DIMENSIONS

Lightolier DPB2S12LS232 — LOUVER CONFIGURATION diagram (page 1)
図 2
Lightolier DPB2S12LS232 — LOUVER CONFIGURATION diagram (page 1)
図 3

5-1/2" (140mm)

2-11/16" (68mm)

24" (610mm)

4" (102mm) 9/32" mounting hole 3/16" x 5/8" K.O.

Lightolier DPB2S12LS232 — 5-1/2" (140mm) diagram (page 1)
図 4 · 5-1/2" (140mm)

7/8" dia. K.O. within 1-7/8" dia. K.O.

MOUNTING METHOD

Lightolier DPB2S12LS232 — MOUNTING METHOD diagram (page 1)
図 5

48" (1219mm)

Job Information Type:

Job Name:

Stem mounting (four per fixture is required)

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2A/Folio G50-80 Rev. B
Show 6 more labels / short text on this page
5-7/8" (149mm) · 20" (508mm) · 12 Cells · 1-7/32" (31mm) · 24" (610mm) · 2" (51mm)
Page 2 of the Lightolier DPB2S12LS232 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

DEEPCELL SURFACE DPB2S12LS232

Page 2 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 12 CELL PARABOLIC LOUVER, 2 LAMP T8 OR T12

PHOTOMETRY MODEL NO. DPB2S12LS232120SO

coefficients of utilization — zonal cavity method

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 83 80 78 76 74 72 73 71 70 2 77 72 68 68 65 62 66 63 61 3 71 64 59 61 57 54 59 56 53 4 65 57 51 55 50 46 53 49 46 5 60 51 45 48 43 39 47 42 39 6 55 45 39 43 38 34 42 37 34 7 50 40 34 39 33 29 37 33 29 8 46 36 29 34 29 25 33 28 25 9 42 32 25 30 25 21 30 25 21 10 39 29 23 27 22 18 27 22 18 visual comfort probability

Lightolier DPB2S12LS232 — PHOTOMETRY MODEL NO. DPB2S12LS232120SO diagram (page 2)
図 6
Lightolier DPB2S12LS232 — PHOTOMETRY MODEL NO. DPB2S12LS232120SO diagram (page 2)
図 7

room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 77 74 75 85 73 70 72 75 20 30 80 77 72 75 77 73 68 71 20 40 83 80 76 75 80 76 71 69 20 60 83 81 79 78 82 79 75 72 30 20 81 76 75 81 78 74 73 74 30 30 83 79 73 72 81 76 69 70 30 40 85 81 76 72 84 79 72 67 30 60 85 81 79 75 85 81 75 71 30 80 85 82 81 77 85 81 77 73 40 20 81 80 77 81 78 77 76 75 40 30 84 82 75 72 82 79 72 70 40 40 86 84 78 72 84 81 74 68 40 60 86 84 80 75 85 83 77 71 40 80 86 84 82 77 85 83 79 74 40 100 86 84 82 77 85 83 79 74 60 30 84 83 77 74 82 80 74 72 60 40 86 85 80 74 84 82 76 70 60 60 86 85 82 76 85 84 79 73 60 80 86 85 83 78 85 84 81 75 60 100 86 85 83 78 85 84 81 75 100 40 86 85 80 76 84 82 77 72 100 60 86 85 82 78 85 84 79 75 100 80 86 85 83 80 86 84 81 78 100 100 86 85 83 81 86 84 81 78

ORDERING INFORMATION Explanation of Catalog Number. Example: DPB2S12LS232120SOGLR

DP

B

S

S

DEEPCELL PARABOLIC:

FIXTURE

NUMBER OF

BALLAST

LAMP QUANTITY:

VOLTAGE:

OPTIONSAdd appropriate suffix to catalog no., ie: (GLR)

WIDTH

CELLS

COVER

BALLAST TYPE: 1-2 Lamp Mag. T12 LE

BODY STYLE:

CEILING

LOUVER FINISH*L = Low-iridescence semi-specular
TYPES =Surface

(standard) P= Low-iridescence specular W=White Paint

LAMP/ FIXTURE LENGTH:

32=T88 34=T12 (Nominal 48")

*Consult factory for availability of louver finishes.

OPTIONS & ACCESSORIES STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24") FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS: Consult factory.

SPECIFICATIONS (CONTINUED): LOUVER: pre-anodized aluminum (Coilzak® or equal). STANDARD FINISH: Louver—low iridescence, semi-specular pre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.

SPECIFICATIONS: PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80. To prevent glare the VCP shall be not less than 85 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 476 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 73%. MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud- welded for rigidity with all seams finished smooth.

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2A/Folio G50-80 Rev. B
Show 10 more labels / short text on this page
room cavity ratio · luminaries lengthwise · luminaries crosswise · 120 or 277 · Pre-anodized · (By Others) · Aluminum · 2=2 Lamp · Louver · Surface Box
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier DPB2S12LS232について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier DPB2S12LS232に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier DPB2S12LS232 取扱説明書(PDF)

2 ページ·289 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…