Page 1 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 32 CELL PARABOLIC LOUVER, 4 LAMP T8 OR T12

DIMENSIONS


2-11/16" (68mm)
24" (610mm)
4" (102mm) 9/32" mounting hole 3/16" x 5/8" K.O.

5-7/8" (149mm)
1-7/32" (31mm)
7/8" dia. K.O. within
24" (610mm)
MOUNTING METHOD
2" (51mm)

Job Information Type:
Job Name:
Stem mounting (four per fixture is required)
Cat. No.:
Lamp(s):
Volts/Ballast:
32 Cells

Page 2 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 32 CELL PARABOLIC LOUVER, 4 LAMP T8 OR T12
coefficients of utilization — zonal cavity method

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 66 64 63 61 59 58 58 57 56 2 62 59 56 56 53 51 54 52 50 3 58 53 50 51 48 46 49 47 45 4 54 48 44 46 43 40 45 42 40 5 50 44 39 42 38 35 41 38 35 6 46 39 35 38 34 31 37 34 31 7 43 36 31 34 30 28 33 30 27 8 39 32 27 31 27 24 30 27 24 9 36 29 24 28 24 21 27 23 21 10 34 26 22 25 21 19 25 21 18 visual comfort probability
F32/T8
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 85 76 70 75 90 80 74 75 20 30 87 80 74 70 91 83 78 78 20 40 87 83 78 73 91 85 82 81 20 60 88 83 81 76 91 85 84 83 30 20 85 80 73 73 90 84 76 74 30 30 87 83 77 69 91 86 80 76 30 40 88 85 80 73 91 87 83 79 30 60 88 85 83 76 91 88 85 82 30 80 88 85 83 76 91 88 85 82 40 20 85 80 76 75 90 84 78 75 40 30 88 84 80 72 91 86 83 77 40 40 88 85 83 75 91 88 85 80 40 60 88 85 84 78 92 88 86 83 40 80 88 85 84 78 92 88 86 83 40 100 88 85 84 78 92 88 86 83 60 30 88 84 80 73 91 87 83 80 60 40 88 85 83 77 92 88 85 82 60 60 88 85 84 80 92 88 87 84 60 80 88 85 84 80 92 88 87 84 60 100 88 85 84 80 92 88 87 84 100 40 88 85 83 77 92 88 85 83 100 60 88 85 84 80 92 88 87 84 100 80 88 85 84 80 92 88 87 85 100 100 88 85 84 80 92 88 87 85
DP
B
S
S
BALLAST
DEEPCELL PARABOLIC:
WIDTH
NUMBER OF
COVER
BALLAST TYPE: 1 & 2 Lamp Mag. T12 LE <20THD <10THD 1 & 2 Lamp Elec. T8 SO* HI* 1-4 Lamp Elec. T8 O4* H4* LOL Dimming T8 PS – *Instant Start Standard Other dimming options. Consult factory.
CEILING
(standard) P= Low-iridescence specular W= White Paint
32=T88 34=T12 (Nominal 48")
*Consult factory for availability of louver finishes.
OPTIONS & ACCESSORIES STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24") FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory.
SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud- welded for rigidity with all seams finished smooth. LOUVER: pre-anodized aluminum (Coilzak® or equal). STANDARD FINISH: Louver—low iridescence, semi-specular pre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
SPECIFICATIONS PERFORMANCE: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To prevent glare the VCP shall be not less than 88 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 254 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 63%.