DEEPCELL SURFACE DPB2S32LS432

Page 1 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 32 CELL PARABOLIC LOUVER, 4 LAMP T8 OR T12

  • Features
  • Only 5-1/2" deep.
  • 20 gauge steel body.
  • 45° mitered corners (body and louver).
  • Side-mounted ballast for cooler operation.
  • Coilzak® aluminum parabolic louver.
  • Vertical grain on louver eliminates reflected lamp images on cross baffle.
  • Perfectly uniform four-side black reveal.
  • Spring-loaded “roosterhead” latches.
  • Reversible louver hinging.
  • Door jamb with integral positive light stop.
  • Flush end K.O.s for smooth surface appearance (at end of row or individual).
  • Protective film dust guard.
  • Louver interchangeable with Prismalyte (PNB).
  • Meets NYC Code requirements.
Lightolier DPB2S32LS432 — DEEPCELL SURFACE DPB2S32LS432 diagram (page 1)
図 1

LOUVER CONFIGURATION

DIMENSIONS

Lightolier DPB2S32LS432 — LOUVER CONFIGURATION diagram (page 1)
図 2
Lightolier DPB2S32LS432 — LOUVER CONFIGURATION diagram (page 1)
図 3

5-1/2" (140mm)

2-11/16" (68mm)

24" (610mm)

4" (102mm) 9/32" mounting hole 3/16" x 5/8" K.O.

Lightolier DPB2S32LS432 — 5-1/2" (140mm) diagram (page 1)
図 4 · 5-1/2" (140mm)

20" (508mm)

5-7/8" (149mm)

1-7/32" (31mm)

7/8" dia. K.O. within

24" (610mm)

MOUNTING METHOD

2" (51mm)

Lightolier DPB2S32LS432 — 20" (508mm) diagram (page 1)
図 5 · 20" (508mm)

48" (1219mm)

Job Information Type:

Job Name:

Stem mounting (four per fixture is required)

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2A/Folio G50-83 REV. B

32 Cells

Page 2 of the Lightolier DPB2S32LS432 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

DEEPCELL SURFACE DPB2S32LS432

Page 2 of 2 2' x 4' SURFACE FLUORESCENT, 3" TYPE, 32 CELL PARABOLIC LOUVER, 4 LAMP T8 OR T12

PHOTOMETRY MODEL NO. DPB2S32LS432120O4

coefficients of utilization — zonal cavity method

Lightolier DPB2S32LS432 — PHOTOMETRY MODEL NO. DPB2S32LS432120O4 diagram (page 2)
図 6

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 66 64 63 61 59 58 58 57 56 2 62 59 56 56 53 51 54 52 50 3 58 53 50 51 48 46 49 47 45 4 54 48 44 46 43 40 45 42 40 5 50 44 39 42 38 35 41 38 35 6 46 39 35 38 34 31 37 34 31 7 43 36 31 34 30 28 33 30 27 8 39 32 27 31 27 24 30 27 24 9 36 29 24 28 24 21 27 23 21 10 34 26 22 25 21 19 25 21 18 visual comfort probability

G90057 DPB2S32LS432120O4

F32/T8

room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 85 76 70 75 90 80 74 75 20 30 87 80 74 70 91 83 78 78 20 40 87 83 78 73 91 85 82 81 20 60 88 83 81 76 91 85 84 83 30 20 85 80 73 73 90 84 76 74 30 30 87 83 77 69 91 86 80 76 30 40 88 85 80 73 91 87 83 79 30 60 88 85 83 76 91 88 85 82 30 80 88 85 83 76 91 88 85 82 40 20 85 80 76 75 90 84 78 75 40 30 88 84 80 72 91 86 83 77 40 40 88 85 83 75 91 88 85 80 40 60 88 85 84 78 92 88 86 83 40 80 88 85 84 78 92 88 86 83 40 100 88 85 84 78 92 88 86 83 60 30 88 84 80 73 91 87 83 80 60 40 88 85 83 77 92 88 85 82 60 60 88 85 84 80 92 88 87 84 60 80 88 85 84 80 92 88 87 84 60 100 88 85 84 80 92 88 87 84 100 40 88 85 83 77 92 88 85 83 100 60 88 85 84 80 92 88 87 84 100 80 88 85 84 80 92 88 87 85 100 100 88 85 84 80 92 88 87 85

ORDERING INFORMATION Explanation of Catalog Number. Example: DPB2S32LS432120O4GLR

DP

B

S

S

FIXTURE

BALLAST

DEEPCELL PARABOLIC:

WIDTH

NUMBER OF

COVER

LAMP QUANTITY(By Others)
VOLTAGE120 or 277
OPTIONSAdd appropriate suffix to catalog no., ie: (GLR)

CELLS

BALLAST TYPE: 1 & 2 Lamp Mag. T12 LE <20THD <10THD 1 & 2 Lamp Elec. T8 SO* HI* 1-4 Lamp Elec. T8 O4* H4* LOL Dimming T8 PS – *Instant Start Standard Other dimming options. Consult factory.

BODY STYLE:

CEILING

LOUVER FINISH*L= Low-iridescence semi-specular
TYPES=Surface

LAMP/ FIXTURE LENGTH:

(standard) P= Low-iridescence specular W= White Paint

32=T88 34=T12 (Nominal 48")

*Consult factory for availability of louver finishes.

OPTIONS & ACCESSORIES STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24") FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory.

SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud- welded for rigidity with all seams finished smooth. LOUVER: pre-anodized aluminum (Coilzak® or equal). STANDARD FINISH: Louver—low iridescence, semi-specular pre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.

SPECIFICATIONS PERFORMANCE: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To prevent glare the VCP shall be not less than 88 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 254 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 63%.

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2A/Folio G50-83 REV. B
Show 6 more labels / short text on this page
room cavity ratio · luminaries lengthwise · luminaries crosswise · Pre- anodized Aluminum · 4=4 Lamp · Surface Box
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier DPB2S32LS432について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier DPB2S32LS432に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier DPB2S32LS432 取扱説明書(PDF)

2 ページ·145 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…