Page 1 of 2 2' x 2' SURFACE FLUORESCENT, 3" TYPE, 9 CELL PARABOLIC LOUVER, 2 LAMP T8 OR T12

DIMENSIONS


2-11/16" (68mm)
24" (610mm)
7/8" K.O.

9/32" mounting hole
MOUNTING METHOD
1-1/4" (32mm)
7/8" Dia. K.O. within 1-7/8" dia. K.O.

3/16" x 5/8" K.O.
Stem mounting (four per fixture is required)
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
9 Cell · 2" (51mm) · 9-1/2" (241mm)

Page 2 of 2 2' x 2' SURFACE FLUORESCENT, 3" TYPE, 9 CELL PARABOLIC LOUVER, 2 LAMP T8 OR T12

coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 66 64 62 60 58 57 58 56 55 2 61 57 53 53 51 48 52 49 47 3 56 50 46 48 44 41 46 43 41 4 51 45 40 43 39 36 41 38 35 5 47 40 35 38 34 31 37 34 31 6 44 36 31 35 31 27 34 30 27 7 41 33 28 32 27 24 31 27 24 8 38 30 25 29 25 22 28 24 22 9 35 28 23 27 23 20 26 22 20 10 33 26 21 25 21 18 24 20 18 visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 69 65 64 72 63 59 57 65 20 30 71 67 64 64 66 61 56 55 20 40 73 69 67 65 68 64 59 55 20 60 74 71 69 67 70 66 62 58 30 20 74 69 64 70 69 64 59 65 30 30 75 70 64 62 71 66 58 55 30 40 76 72 67 63 72 68 61 56 30 60 77 73 68 65 74 69 63 58 30 80 78 74 70 67 75 71 65 60 40 20 77 73 68 69 72 69 63 66 40 30 78 74 67 63 73 70 62 57 40 40 78 75 69 63 75 71 64 58 40 60 79 75 70 65 76 72 66 60 40 80 80 76 72 67 77 74 68 62 40 100 80 77 73 68 77 75 69 64 60 30 79 75 70 65 76 72 65 60 60 40 80 76 71 65 77 73 67 60 60 60 80 77 72 67 77 74 68 62 60 80 80 78 73 68 78 75 70 64 60 100 81 78 74 69 79 76 71 65 100 40 81 78 74 70 78 75 70 64 100 60 81 79 74 70 79 76 71 65 100 80 82 79 75 71 79 77 72 67 100 100 82 80 76 72 80 77 73 68
DP
B
S
S
BALLAST
NUMBER OF
COVER
CELLS 9 or 12
BALLAST TYPE: 1-2 Lamp Mag. T12 LE
CEILING
(standard) P=Low-iridescence specular W=White Paint
*Consult factory for availability of louver finishes.
OPTIONS & ACCESSORIES STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is required.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24"). FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory.
SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud- welded for rigidity with all seams finished smooth. LOUVER: pre-anodized aluminum (Coilzak® or equal). STANDARD FINISH: Louver—low iridescence, semi-specular pre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
SPECIFICATIONS PERFORMANCE: In an installation of 2U lamp 31W luminaires in a room cavi- ty ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .64. To prevent glare the VCP shall be not less than 77 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 2319 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 68.4%.