Page 1 of 2 2' x 2' SURFACE FLUORESCENT, 3" TYPE, 9 CELL PARABOLIC LOUVER 3 LAMP TWIN TUBE T5, 1-5/8" U LAMP OR 2' LAMP T8

DIMENSIONS


2-11/16" (68mm)
24" (610mm)
MOUNTING METHOD
7/8" K.O.


1-1/4" (32mm)
7/8" Dia. K.O. within 1-7/8" dia. K.O.
3/16" x 5/8" K.O.
Stem mounting (four per fixture is required)
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
9 Cell · 2" (51mm) · 9-1/2" (241mm)

Page 2 of 2 2' x 2' SURFACE FLUORESCENT, 3" TYPE, 9 CELL PARABOLIC LOUVER 3 LAMP TWIN TUBE T5, 1-5/8" U LAMP OR 2' LAMP T8

coefficients of utilization — zonal cavity method
RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 69 67 65 63 61 60 60 59 58 2 64 60 57 57 55 53 55 53 52 3 60 55 51 52 49 47 51 48 46 4 55 50 45 47 44 41 46 43 41 5 51 45 40 43 39 36 42 38 36 6 47 40 36 39 35 32 38 34 32 7 44 36 32 35 31 28 34 31 28 8 40 33 28 32 27 24 31 27 24 9 37 29 25 28 24 21 28 24 21 10 34 27 22 26 22 19 25 21 19 visual comfort probability
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 71 62 58 62 75 67 63 71 20 30 75 67 61 55 78 72 68 59 20 40 75 71 66 59 81 75 72 64 20 60 75 71 70 63 83 77 75 68 30 20 75 69 60 63 80 73 83 69 30 30 79 73 63 56 83 70 68 59 30 40 79 76 68 60 85 79 72 63 30 60 79 76 71 64 86 80 75 67 30 80 79 76 71 64 85 80 75 70 40 20 75 69 65 64 80 73 68 69 40 30 79 74 68 58 83 77 72 60 40 40 79 77 72 61 85 79 75 64 40 60 79 77 75 65 85 80 78 68 40 80 79 77 75 65 85 80 78 70 40 100 79 77 75 65 85 80 78 70 60 30 79 74 69 61 83 77 74 63 60 40 79 77 73 65 84 80 78 67 60 60 79 77 77 68 85 80 80 70 60 80 79 77 77 69 85 80 80 73 60 100 79 77 77 69 85 80 80 73 100 40 79 77 73 65 84 80 78 67 100 60 79 77 77 69 85 80 80 71 100 80 80 77 76 70 85 80 80 73 100 100 80 77 76 70 85 80 80 74
DP
B
S
S
NUMBER OF
BALLAST
CELLS 9 or 12
BALLAST TYPE:
CEILING
(standard) P= Low-iridescence specular W=White Paint
LAMP/ FIXTURE LENGTH: 2U=T8, 1-5/8" U Lamp FT=Twin Tube T5 17=T8, 2' Lamp (Nominal 24")
*Consult factory for availability of louver finishes.
OPTIONS & ACCESSORIES STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24") FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory.
SPECIFICATIONS (continued) welded for rigidity with all seams finished smooth. LOUVER: pre-anodized aluminum (Coilzak® or equal). STANDARD FINISH: Louver—low iridescence, semi-specular pre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
SPECIFICATIONS PERFORMANCE: In an installation of 3U lamp 40W luminaires in a room cavi- ty ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .67. To prevent glare the VCP shall be not less than 79 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 682 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 64%. MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud-