DEEPCELL SURFACE DPB2S9LS3FT/2U OR 17

Page 1 of 2 2' x 2' SURFACE FLUORESCENT, 3" TYPE, 9 CELL PARABOLIC LOUVER 3 LAMP TWIN TUBE T5, 1-5/8" U LAMP OR 2' LAMP T8

Lightolier DPB2S9LS3FT/2U — DEEPCELL SURFACE DPB2S9LS3FT/2U OR 17 diagram (page 1)
図 1
  • Features
  • Only 5-1/2" deep.
  • 20 gauge steel body.
  • 45° mitered corners (body and louver).
  • Side-mounted ballast for cooler operation.
  • Coilzak® aluminum parabolic louver.
  • Vertical grain on louver eliminates reflected lamp images on cross baffle.
  • Perfectly uniform four-side black reveal.
  • Spring-loaded “roosterhead” latches.
  • Reversible louver hinging.
  • Door jamb with integral positive light stop.
  • Flush end K.O.s for smooth surface appearance (at end of row or individual).
  • Protective film dust guard.
  • Louver interchangeable with Prismalyte (PNB).
  • Meets NYC Code requirements.

LOUVER CONFIGURATION

DIMENSIONS

Lightolier DPB2S9LS3FT/2U — LOUVER CONFIGURATION diagram (page 1)
図 2
Lightolier DPB2S9LS3FT/2U — LOUVER CONFIGURATION diagram (page 1)
図 3

5-1/2" (140mm)

2-11/16" (68mm)

24" (610mm)

3" (76mm)

MOUNTING METHOD

7/8" K.O.

Lightolier DPB2S9LS3FT/2U — 3" (76mm) diagram (page 1)
図 4 · 3" (76mm)

16-1/2" (419mm)

Lightolier DPB2S9LS3FT/2U — 16-1/2" (419mm) diagram (page 1)
図 5 · 16-1/2" (419mm)

9/32" mounting hole

1-1/4" (32mm)

7/8" Dia. K.O. within 1-7/8" dia. K.O.

24" (610mm)

3/16" x 5/8" K.O.

24" (610mm)

Stem mounting (four per fixture is required)

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2A/Folio G50-86 REV. B

9 Cell · 2" (51mm) · 9-1/2" (241mm)

Page 2 of the Lightolier DPB2S9LS3FT/2U user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

DEEPCELL SURFACE DPB2S9LS3FT/2U OR 17

Page 2 of 2 2' x 2' SURFACE FLUORESCENT, 3" TYPE, 9 CELL PARABOLIC LOUVER 3 LAMP TWIN TUBE T5, 1-5/8" U LAMP OR 2' LAMP T8

PHOTOMETRY MODEL NO. DPB2S9LS3FT120X3

Lightolier DPB2S9LS3FT/2U — PHOTOMETRY MODEL NO. DPB2S9LS3FT120X3 diagram (page 2)
図 6

coefficients of utilization — zonal cavity method

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 69 67 65 63 61 60 60 59 58 2 64 60 57 57 55 53 55 53 52 3 60 55 51 52 49 47 51 48 46 4 55 50 45 47 44 41 46 43 41 5 51 45 40 43 39 36 42 38 36 6 47 40 36 39 35 32 38 34 32 7 44 36 32 35 31 28 34 31 28 8 40 33 28 32 27 24 31 27 24 9 37 29 25 28 24 21 28 24 21 10 34 27 22 26 22 19 25 21 19 visual comfort probability

G90051 DPB2S9LS3FT120X3

room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 71 62 58 62 75 67 63 71 20 30 75 67 61 55 78 72 68 59 20 40 75 71 66 59 81 75 72 64 20 60 75 71 70 63 83 77 75 68 30 20 75 69 60 63 80 73 83 69 30 30 79 73 63 56 83 70 68 59 30 40 79 76 68 60 85 79 72 63 30 60 79 76 71 64 86 80 75 67 30 80 79 76 71 64 85 80 75 70 40 20 75 69 65 64 80 73 68 69 40 30 79 74 68 58 83 77 72 60 40 40 79 77 72 61 85 79 75 64 40 60 79 77 75 65 85 80 78 68 40 80 79 77 75 65 85 80 78 70 40 100 79 77 75 65 85 80 78 70 60 30 79 74 69 61 83 77 74 63 60 40 79 77 73 65 84 80 78 67 60 60 79 77 77 68 85 80 80 70 60 80 79 77 77 69 85 80 80 73 60 100 79 77 77 69 85 80 80 73 100 40 79 77 73 65 84 80 78 67 100 60 79 77 77 69 85 80 80 71 100 80 80 77 76 70 85 80 80 73 100 100 80 77 76 70 85 80 80 74

ORDERING INFORMATION Explanation of Catalog Number. Example: DPB2S9LS3FT120X3GLR

DP

B

S

S

DEEPCELL PARABOLICPre-anodized

FIXTURE

NUMBER OF

BALLAST

LAMP QUANTITY(By Others)
VOLTAGE120 or 277
OPTIONSAdd appropriate suffix to catalog no., ie: (GLR)

WIDTH

CELLS 9 or 12

COVER

BALLAST TYPE:

CEILING

LOUVER FINISH*L = Low-iridescence semi-specular

BODY STYLE:

TYPES =Surface

(standard) P= Low-iridescence specular W=White Paint

LAMP/ FIXTURE LENGTH: 2U=T8, 1-5/8" U Lamp FT=Twin Tube T5 17=T8, 2' Lamp (Nominal 24")

*Consult factory for availability of louver finishes.

OPTIONS & ACCESSORIES STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface. (Four per fixture is recommended.) Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC24 CSP (24") FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard. SUFFIX: RF. ELECTRICAL/WIRING OPTIONS Consult factory.

SPECIFICATIONS (continued) welded for rigidity with all seams finished smooth. LOUVER: pre-anodized aluminum (Coilzak® or equal). STANDARD FINISH: Louver—low iridescence, semi-specular pre-anodized vertical grain reflector sheet. Cavity—white baked acrylic enamel minimum 86% reflectance. Phosphate undercoating. Chassis exterior—white baked acrylic enamel. ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.

SPECIFICATIONS PERFORMANCE: In an installation of 3U lamp 40W luminaires in a room cavi- ty ratio of 1, with a reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .67. To prevent glare the VCP shall be not less than 79 either lengthwise or cross wise (at 100fc level) and the average brightness at 65° shall not exceed 682 footlamberts. To control veiling reflections, luminaire output in the 30°-90° zone shall be not less than 64%. MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel, stud-

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) A0902 Section 2A/Folio G50-86 REV. B
Show 7 more labels / short text on this page
room cavity ratio · luminaries lengthwise · luminaries crosswise · Aluminum · 3=3 Lamp · Louver · Surface Box
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier DPB2S9LS3FT/2Uについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier DPB2S9LS3FT/2Uに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier DPB2S9LS3FT/2U 取扱説明書(PDF)

2 ページ·154 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…