目次 12セクション Eye-QLB EYS4LNFR354 · Mounting Methods Dimensions · Job Information Type: · CANDELA DISTRIBUTION 0 · … 表示非表示
Page 1 of the Lightolier EYS4LNFR332 user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

Eye-QLB EYS4LNFR354

Page 1 of 2 Linear Prismatic Lens, 85% Downlight, 15% Uplight 48" Length 3 Lamp T5/T8, 96" Length 3 Lamp T5/T8 in Tandem

  • Features
  • Ideal for stores, schools, labs.
  • Acrylic linear, prismatic lens.
  • 85% downlight,15% uplight.
  • 75.1% efficient (3 lamp 54W T5). 70.4% efficient (3 lamp 32W T8).
  • 1.5 spacing mounting ratio (3 lamp 54W T5).
  • 1.4 spacing mounting ratio (3 lamp 32W T8).
  • Can be pendant or surface mounted.
  • 48" or 96" modular lengths.
  • 95% reflective Specular Aluminum top Reflector.
  • 20 gauge steel housing. 18 gauge steel ends.
  • 22 gauge steel side reflectors.
  • Flat white acrylic baked enamel, post painted.
  • Lens can hinge from either side.
  • Lens safety chain standard.
  • Removeable upper end cap for thru wiring.
  • Can be stem or cable mounted at fixture joints.
  • K.O. in upper end cap for occupancy sensor.
  • Heavy duty coupler available.
  • Meets NYC Code requirements.
Lightolier EYS4LNFR332 — Eye-QLB EYS4LNFR354 diagram (page 1)
図 1 · Eye-QLB EYS4LNFR354

Mounting Methods Dimensions

Lightolier EYS4LNFR332 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions

can be stem mounted at fixture joints

Lightolier EYS4LNFR332 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions

can be cable mounted at fixture joints

Lightolier EYS4LNFR332 — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

S Hook Slots (8)

Lightolier EYS4LNFR332 — Mounting Methods Dimensions diagram (page 1)
図 5 · Mounting Methods Dimensions

7/8” Dia. K.O.

Lightolier EYS4LNFR332 — Mounting Methods Dimensions diagram (page 1)
図 6 · Mounting Methods Dimensions
Lightolier EYS4LNFR332 — Mounting Methods Dimensions diagram (page 1)
図 7 · Mounting Methods Dimensions

can be suspended with chain hanger sets Catalog No. AH5 CSP

heavy duty coupler, required for continuous row mounting. Catalog No. EY COUPLER

11/16” Dia. K.O. (2 Places)

39-3/8” (999mm) 41-3/4” (1059mm) 48” (1220mm)

Lightolier EYS4LNFR332 — Mounting Methods Dimensions diagram (page 1)
図 8 · Mounting Methods Dimensions

S Hook Slots (8)

7/8” Dia. K.O. (2 places)

11/16” Dia. K.O. (2 Places) 48” (1220mm) 87-3/8” (2219mm) 89-3/4" (2279mm) 96" (2441mm)

Lightolier EYS4LNFR332 — Mounting Methods Dimensions diagram (page 1)
図 9 · Mounting Methods Dimensions
  • Luminaire-Mounted Motion Sensor 360° coverage, up to 45 ft. mounting distance. Field installed. Catalog Number: FHB360 .
  • Line voltage accepts 120 through 347 volt applications.
  • Uses passive infrared (PIR) technology shielded by a fresnel lens; upon detection of infrared energy levels, the sensor is triggered and switches the light on.
  • Light shuts off after a time delay unit that is factory preset at 10 minutes, manually adjustable from 30 sec. to 20 min. using tool included.
  • Mounts on either end using 7/8" knockouts provided.

Job Information Type:

Job Name:

Cat. No.:

optional occupancy sensor see folio OA60-10

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K60-10
Show 7 more labels / short text on this page
5-3/16" (132mm) · 8-15/16" (227mm) · 4-3/8” (111mm) · 3-1/8” (81mm) · 4-3/8” (111mm) · 3-1/8” (81mm) · 1/06
Page 2 of the Lightolier EYS4LNFR332 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Eye-QLB EYS4LNFR354

Page 2 of 2 Linear Prismatic Lens, 85% Downlight, 15% Uplight 48" Length 3 Lamp T5/T8, 96" Length 3 Lamp T5/T8 in Tandem

Model No. EYS4LNFR332UNVH3 LER = FP - 63.0 IW - 84.52 BF - 0.89 Comparative yearly lighting energy cost per

Model No. EYS4LNFR354UNVPU LER = FP - 64.9 IW - 152.5 BF - 1.00 Comparative yearly lighting energy cost per

1000 lumens = $3.81

CANDELA DISTRIBUTION 0

1000 lumens = $3.70

CANDELA DISTRIBUTION 0

Lightolier EYS4LNFR332 — CANDELA DISTRIBUTION 0 diagram (page 2)
図 10

0.0 45.0 90.0 FLUX

Lightolier EYS4LNFR332 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 11

Report Number: G2005278 Catalog Number: EYS4LNFR332UNVH3 Lamps: F32T8/TL841 Luminaire: Eye-Q LB with solid sides, linear prismatic lens and 15% uplight specular reflector Ballast: Triad B332I120RH-A Report is based on 2850 Lumens per lamp. Efficiency: 70.4% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 48.000 9.000 Height of Side: 3.960 3.960

Report Number: G2005293 Catalog Number: EYS4LNFR354UNVP5 Lamps: FP54/835 Luminaire: Eye-Q LB with solid sides, linear prismatic lens and 15% uplight specular reflector. Ballast: Universal B454IUNV-E Report is based on 4400 Lumens per lamp. Efficiency: 75.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.5 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 48.000 9.000 Height of Side: 3.960 3.960

0.0 45.0 90.0 FLUX

0 1739 1739 1739

0 2649 2649 2649

5 1711 1743 1772 166

5 2628 2655 2703 255

15 1616 1696 1703 474

15 2477 2700 2727 748

25 1459 1492 1551 697

25 2238 2408 2410 1102

35 1257 1316 1608 868

35 1986 2052 2517 1373

45 1002 1209 1355 911

45 1693 1959 2345 1514

55 715 945 979 787

55 1244 1639 1640 1338

65 429 626 748 592

65 752 1102 1222 1006

75 184 364 532 385

75 344 626 911 671

85 30 196 328 208

85 57 357 641 396

90 14 131 239

90 13 256 476

95 26 112 205 125

95 59 156 285 180

105 70 75 112 84

105 165 93 174 128

COEFFICIENTS OF UTILIZATION –

115 120 68 87 86

COEFFICIENTS OF UTILIZATION –

115 278 68 104 121

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

125 169 98 85 108

125 386 119 70 151

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

135 215 174 121 133

135 487 222 140 205

01 74 70 67 62 60 58 58 56 54 02 67 61 56 54 51 48 50 48 45 03 61 53 48 48 43 40 44 41 38 04 56 47 41 42 38 34 40 36 32 05 51 42 36 38 33 29 35 31 28 06 47 38 32 34 29 26 32 28 25 07 44 34 28 31 26 23 29 25 22 08 41 31 25 28 24 20 27 22 19 09 38 29 23 26 21 18 25 20 17 10 36 26 21 24 20 16 23 19 16 ZONE LUMENS % LAMP % FIXT 00-030 1337 15.6 22.2 00-040 2204 25.8 36.6 00-060 3903 45.6 64.8 00-090 5088 59.5 84.5 90-120 295 3.5 4.9 90-130 403 4.7 6.7 90-150 687 8.0 11.4 90-180 935 10.9 15.59 00-180 6023 70.4 100.0

145 255 253 208 151

01 78 74 71 66 64 61 61 59 58 02 71 64 59 58 54 50 52 50 47 03 64 56 50 51 46 42 47 43 40 04 59 50 43 45 40 35 42 37 34 05 54 44 38 40 35 31 37 33 29 06 50 40 33 36 31 27 34 29 25 07 46 36 29 33 27 23 31 26 22 08 43 33 26 30 25 21 28 23 20 09 40 30 24 27 22 19 26 21 18 10 37 28 22 25 20 17 24 19 16 ZONE LUMENS % LAMP % FIXT 00-030 2104 15.9 21.2 00-040 3478 26.3 35.1 00-060 6329 47.9 63.9 00-090 8402 63.7 84.8 90-120 429 3.3 4.3 90-130 580 4.4 5.9 90-150 1028 7.8 10.4 90-180 1505 11.4 15.2 00-180 9907 75.1 100.0

145 573 367 258 243

155 288 285 286 132

155 640 493 427 235

165 311 306 308 87

165 688 621 578 176

175 323 314 315 30

175 707 692 691 66

180 316 316 316

180 694 694 694

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4695. 4862. 4773. 55 4000. 4304. 3759. 65 3094. 3405. 3266. 75 1950. 2554. 2790. 85 635. 2024. 2239.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 7933. 7878. 8260. 55 6959. 7464. 6298. 65 5423. 5994. 5336. 75 3645. 4392. 4778. 85 1207. 3686. 4375.

Ordering Information Explanation of Catalog Number. Example: EYS4LNFR332UNVH3

EY

LN

F

R

Eye-Q LBSuspended/

Fixture Length:

FinishF =Flat

R= 15% Uplight

Lamp Quantity3 =3 Lamp 3 Lamps in Tandem for
Lamp Type(By Others)
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog

4=48" 8=96"

32=T8 28=T5 54=T5 (Nominal 48")

no., ie(GLR)

96" Units Ballast Type:

Options/Accessories Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface. Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"), ASC 24 CSP (24"). Fusing: Internal fast blow fusing: SUFFIX: GLR.

Other dimming options. Consult factory. †*Instant Start Standard ††Instant Start (120V or 277V only) ††Program Rapid Start (UNV only) NOTE: For T8 UNV, you must use HI, H3 Ballast Code.

Internal slow blow fusing: SUFFIX: GMF. Emergency Pack: Factory-installed emergency power battery pack with charger and inverter. SUFFIX: LP400 (T8). LP550 (T5). Cable Hangers: Adjustable 6"-60". Single Cable and Canopy: Catalog Number: WC60. Single Cable, Straight Cord and Canopy: Catalog Number: WCC60**. Single Cable, Coil Cord and Canopy: Catalog Number: WCCC60**. Chain Hanger Kits: Catalog Number: AH5 CSP. **Cord, 3-#18 wires.

Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

Specifications Materials: Housing is die-formed 20 gauge cold rolled steel with full length channel for thru wiring. Fixture Ends: 18 gauge cold rolled steel. Lens: Linear Prismatic. Side Reflectors: Solid 22 gauge cold rolled steel. Finish: Post painted white acrylic baked enamel.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio K60-10
Show 9 more labels / short text on this page
S=Solid · LN=Linear · Sides P=Perforated · Prismatic Lens · Reflector · Surface Fluorescent · White · Sides · Luminaire
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier EYS4LNFR332について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier EYS4LNFR332に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier EYS4LNFR332 取扱説明書(PDF)

2 ページ·335 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…