JA
Lightolier logo
公式取扱説明書

Lightolier F7000-11

2 ページ·143 KB·インテリア家具・調度品·PDF·EN
Lightolier F7000-11
目次 19セクション Lighting Systems F7000-11 · 1BHFPG '4FSJFT-JHIU51JFSDFE8BMM.PVOU · 6. Shielding Pattern · Ordering Information · … 表示非表示
Page 1 of the Lightolier F7000-11 user manual — Family Series
1ページ · クリックして拡大
1ページ

Lighting Systems F7000-11

1BHFPG '4FSJFT-JHIU51JFSDFE8BMM.PVOU

Lightolier F7000-11 — Lighting Systems F7000-11 diagram (page 1)
図 1 · Lighting Systems F7000-11

1.557” (3.95cm)

1.750” (4.45cm)

6. Shielding Pattern

Ordering Information

Family Series

Type Lamps Color Wattage Voltage Length

FW7

2 = Oval 2 = Pattern Pierced

1 = 1 Lamp AL = Aluminum WH = White

1 = 28W 2 = 54W 3 = 28W Dimming 4 = 28W EM 5 = 54W Dimming 6 = 54W EM

1 = 120v 2 = 277v 4 = 4’ (121.92cm) 8 = 8’ (243.84cm)

Complete Ordering Instructions below.

Features for Wall Modules 1. Housing: Single piece of high purity extruded aluminum, a portion from recycled material. 2. Housing End: Die-cast aluminum, welded in place. 3. End cap: Die-cast aluminum. Encloses the end of the run. 4. Lamps: F28T5 or F54T5HO as specified. By others. Installed from the ceiling side of the luminaire. 5. Ballast: Electronic. Meets ANSI starting, end-of-life protection and sound rating specifications. Low THD. 6. Shielding: Perforated square-in-square pattern pierced in extruded housing, regressed and backed by 0.20” (0.51cm) opal acrylic.

Finish Powder-coated, baked enamel, white or aluminum, as specified.

Ordering Instructions for Wall Modules Individual Fixtures: 1. Order one MODULE. 2. Order one END SET. Continuous Rows: 1. Order the appropriate number of MODULES for the complete run. 2. Order one END SET.

Electrical Connections: Pre-wired with 18 gauge wires and polarized cannon plug con- nectors for simultaneous mechanical/electrical connection. Emergency Battery Pack: 90 minute operation, 700 lumens for 54W and 520 lumens for 28W. Dimming: Advance Mark X standard (no additional wires required); use compat- ible dimmer. Dimming ballasts using additional control wires (eg Lutron Hi-Lume or ECO-10, Osram) can be used; consult factory and use X4 or X5 power feeds with additional leads, as appropriate. Ballast not to exceed 1.25” (3.18cm) wide by 1.20” (3.05cm) high. iGEN: F7000 accepts iGEN (DALI) with supplemental 2-wire control technology. Use with X5 power feed. Power Tray: Code-gauge, die-formed steel, pre-paint white enamel finish; secured by quarter-turn fasteners for easy access to wiring. Holds ballasts, sockets, and wiring. Accepts ballasts up to 1.25” (3.18cm) wide by 1.20” (3.05cm) high.

Lightolier F7000-11 — Family Series diagram (page 1)
図 2 · Family Series

Factory installed ballast disconnect allows the ballast to be disconnected from and reconnected to incoming power under load without turning the entire circuit off.

"JSQPSU3PBE 'BMM3JWFS ."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

&

Page 2 of the Lightolier F7000-11 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Lighting Systems F7000-11

1BHFPG '4FSJFT-JHIU51JFSDFE8BMM.PVOU

Performance

COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE

CANDLEPOWER CURVE

CANDLEPOWER

Lightolier F7000-11 — COEFFICIENTS OF UTILIZATION % EFFECTIVE CEILING CAVITY REFLECTANCE diagram (page 2)
図 3

ZONE 0 22 45 67 90 DEG.

WALL REFLECTANCE 50 30 1050 30 1050 30 10

CANDELAS

Lightolier F7000-11 — CANDELAS diagram (page 2)
図 4

0 217 5 216 217 218 216 213 15 211 209 200 195 187 25 193 189 173 164 153 35 164 155 136 126 112 45 127 116 94 81 64 55 84 76 51 45 40 65 39 36 27 28 25 75 12 12 12 15 12 85 4 5 5 5 1 90 4 3 2 1 0 95 55 56 61 78 38 105 279 287 303 315 184 115 560 567 571 519 355 125 822 815 769 679 519 135 972 960 915 793 663 145 1073 1054 990 876 788 155 1085 1065 1011 935 881 165 1039 1029 1003 965 943 175 983 982 983 977 975 180 971

ROOM CAVITY RATIO

20% FLOOR CAVITY REFLECTANCE

DISTRIBUTION

Zone Lumens % Lamp %Luminaire 0 - 90 382 7.6 11.0 90 - 180 3099 61.8 89.0 0 - 180 3481 69.4 100.0

REPORT NO.: ITL54692.IES LAMPS: 1C LUMENS: 5000 each EFFICIENCY: 69.4% CAT. NO.: F7221WH214

Fixture Lengths & Mounting Reflected (Plan View)

Lightolier F7000-11 — Fixture Lengths & Mounting Reflected (Plan View) diagram (page 2)
図 5 · Fixture Lengths & Mounting Reflected (Plan View)

6'-8" (203.20cm) 1'-4" (40.64cm) 6'-8" (203.20cm) 2'-8" (81.28cm) 1'-4" (40.64cm)

Recommended mounting is a single gang outlet box rotated 90 degrees at the feed point. Remaining mounting points could be outlet boxes as well, or a couple of holes per mounting point spaced 3-1/4” (8.26cm) at 1-3/4” (4.45cm) above the bottom of fixture.

Mounting Accessories

Wall Mount End Set FW7EWH = White FW7EAL = Aluminum

Job Information Type:

"JSQPSU3PBE 'BMM3JWFS ."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

&

Lightolier F7000-11について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier F7000-11に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier F7000-11 取扱説明書(PDF)

2 ページ·143 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…