Page of 2 Wall/Ceiling Mounted T5 Fluorescent ADA Compliant


Features 1. Diffuser Holder: (2) Die-cast aluminum. One stationary and one spring loaded for ease of diffuser removal and lamping. 2. Lamp Housing: Extruded aluminum. 3. Ballast Housing: (2) Die-cast aluminum. 5. Junction Box Mounting Plate: 18ga. C.R.S zinc plated. For mounting to standard 4” octagonal junction box. Not required for conduit mounted installations. 6. Backplate: 18ga. C.R.S. zinc plated. Provided with (2) 7/8” diameter conduit knockouts (for non junction box installation) and (2) 3/16” diameter mounting holes for direct mounting to wall or ceiling surface (hardware not provided). 7. Luminaire Ballast Disconnect: Meets NEC 410.130 (G) and CEC disconnect requirements 8. Lampholder: Fluorescent- Mini Bi-Pin, G5 Base 9. Junction Box Cover: (2) Die-cast aluminum with integral spring clip for easy snap-on installation (provided with luminaire). Not required for conduit mounted installation. 10. Diffuser: Either 3mm curved opal acrylic or opal glass.
Labels cULus Listed. Suitable for Damp Locations.


Backplate Detail

Page of 2 Wall/Ceiling Mounted T5 Fluorescent ADA Compliant
FC21U-FCA2

DECORATIVE LUMINAIRE CAT. # FC21U/FCA2, 21W SYLVANIA T-5 LAMPS. LUMEN RATING = 1890 LMS. BALLAST/ ADVANCE ICN-2S28
Angle Along 22.5. 45 67.5 Across. Output Lumens 0 303 5 305 302 300 302 300 29 10 296 293 291 294 292 83 15 276 275 274 276 274 127 25 276 275 274 276 274 127 35 247 247 246 248 248 155 45 210 211 211 214 214 164 55 165 167 169 174 175 152 65 114 117 124 131 134 123 75 60 66 79 90 95 84 85 13 25 44 58 63 49 90 3 18 41 60 67 95 14 25 61 85 94 56 105 45 24 39 64 76 51 115 51 38 46 52 54 47 125 51 57 56 62 64 52 135 50 56 66 69 70 49 145 55 55 73 76 76 42 155 55 53 66 74 76 30 165 48 47 46 62 67 15 175 69 63 55 40 40 180 55
0 .78 .74 .67 .67 .67 .60 .60 .60 .54 .54 .54 .51
1 .71 .68 .65 .62 .67 .65 .62 .59 .58 .56 .54 .52 .51 .49 .47 .46 .45 .42
2 .65 .59 .54 .50 .61 .56 .52 .48 .51 .47 .45 .46 .43 .41 .41 .39 .37 .35
3 .59 .52 .47 .42 .56 .49 .45 .41 .45 .41 .38 .41 .37 .35 .37 .34 .32 .30
4 .54 .46 .40 .36 .51 .44 .39 .34 .40 .35 .32 .36 .33 .30 .33 .30 .27 .25
5 .49 .40 .34 .30 .46 .39 .33 .29 .35 .31 .27 .32 .28 .25 .29 .26 .23 .21
6 .45 .36 .30 .26 .43 .35 .29 .25 .31 .27 .23 .29 .25 .22 .26 .23 .20 .18
7 .42 .32 .27 .23 .39 .31 .26 .22 .28 .24 .20 .26 .22 .19 .23 .20 .18 .16
8 .38 .29 .23 .19 .36 .28 .22 .19 .25 .21 .18 .23 .19 .16 .21 .18 .15 .14
9 .35 .26 .21 .17 .33 .25 .20 .16 .23 .18 .15 .21 .17 .14 .19 .16 .13 .12
10 .33 .24 .18 .15 .31 .23 .18 .14 .21 .16 .13 .19 .15 .12 .17 .14 .12 .10
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 27.0
Zonal Lumens and Percentages Zone Lumens % Lamp %Luminaire 0-30 238 12.62 18.18 0-40 393 20.83 30.01 0-60 709 37.56 54.10 0-90 965 51.07 73.57 40-90 571 30.24 43.57 60-90 255 13.52 19.47 90-180 346 18.34 26.43 0-180 1311 69.41 100.00 ** Efficiency = 69.4% **
Certified Test Report no. 3627FR Computed by LSI Program **TEST-LITE** SC= 1.3 Prepared For: Lightolier Fall River, MA
0° 30°
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.