Page 1 of the Lightolier FRS2GFW224 user manual — Lightolier is a Philips group brand
1ページ · クリックして拡大
1ページ

FRX Series FRS2GFW224 or 324

Page 1 of 2 Architectural Recessed Fluorescent 2' x 2' with Frost White Acrylic Lens, 2 or 3 Lamp T5HO

  • Features
  • Ideal for boardrooms, entrances and other spaces seeking a clean architectural look.
  • Frost White DR acrylic lens.
  • Can be mounted in patterns, end to end or side to side.
  • Blends in with regular flat-edge and aesthetic recessed-edge ceiling tiles.
  • 70.0% efficient (3 Lamp 24 watt T5HO)
  • 66.0% efficient (2 Lamp 24 watt T5HO)
  • 5" deep body.
  • One piece housing.
  • Black exterior for cooler ballast operating temperature.
  • Built-in earthquake clips (patent no. 5,072,344).
  • Spring loaded latches/hinge.
  • Lens encloses lamp compartment.
  • Lens opens from either side.
  • Ballast accessible from room side.
  • Wiring access plate standard.
  • Construction to meet NYC Code or Chicago Plenum available.
Lightolier FRS2GFW224 — FRX Series FRS2GFW224 or 324 diagram (page 1)
図 1 · FRX Series FRS2GFW224 or 324

Mounting Methods Dimensions

24" (610mm)

Lightolier FRS2GFW224 — 24" (610mm) diagram (page 1)
図 2 · 24" (610mm)
Lightolier FRS2GFW224 — 24" (610mm) diagram (page 1)
図 3 · 24" (610mm)
Lightolier FRS2GFW224 — 24" (610mm) diagram (page 1)
図 4 · 24" (610mm)

2" max.

2" max.

5" (127mm)

23-7/8" (606mm) Square Lens 13/16" (21mm)

24" (610mm)

5" (127mm)

G G

exposed T-grid ceiling.

13/16" (21mm) 23-7/8" (606mm) Square Lens

Lightolier FRS2GFW224 — 13/16" (21mm) 23-7/8" (606mm) Square Lens diagram (page 1)
図 5 · 13/16" (21mm) 23-7/8" (606mm) Square Lens
Lightolier FRS2GFW224 — 13/16" (21mm) 23-7/8" (606mm) Square Lens diagram (page 1)
図 6 · 13/16" (21mm) 23-7/8" (606mm) Square Lens

Drywall Kit (See Options)

24" (610mm)

2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s

Drywall Kit, Catalog Number: FK92X2.

Lightolier FRS2GFW224 — 24" (610mm) diagram (page 1)
図 7 · 24" (610mm)

5" (127mm)

Job Information Type:

Job Name:

Expample of pattern mounting

Cat. No.:

Lamp(s):

Volts/Ballast:

  • For Factory Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 a Philips Group Section 5/Folio MA10-11

Lightolier is a Philips group brand

Show 10 more labels / short text on this page
15/16" or 9/16" · 15/16" or 9/16" · 24" · 24" · Tegular grid ceiling · FRX Fixture · Support (by others) · Drywall (by others) · hold-down clips · 11/08
Page 2 of the Lightolier FRS2GFW224 user manual — Lightolier is a Philips group brand
2ページ · クリックして拡大
2ページ

FRX Series FRS2GFW224 or 324

Page 2 of 2 Architectural Recessed Fluorescent 2' x 2' with Frost White Acrylic Lens, 2 or 3 Lamp T5HO

Model No. FRS2GFW224UNVPG LER = FP - 42.0 IW - 50.8 BF - 0.88 Comparative yearly lighting energy cost per

Model No. FRS2GFW324UNVPG LER = FP - 48.3 IW - 78.3 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $5.71

CANDELA DISTRIBUTION

1000 lumens = $4.97

CANDELA DISTRIBUTION

Lightolier FRS2GFW224 — CANDELA DISTRIBUTION diagram (page 2)
図 8

0.0 45.0 90.0 FLUX

Lightolier FRS2GFW224 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 9

0.0 45.0 90.0 FLUX

Report NumberG2008268 Catalog Number: FRS2GFW224UNVPG Lamps: (2) F25T5HO Luminaire: FRX Arch itectural Recessed
Report NumberG2008286 Catalog Number: FRS2GFW324UNVPG Lamps: (3) F24T5HO/835/ALTO/PLPS Luminaire: FRX Arch itectural Recessed

0 869 869 869

0 1328 1328 1328

5 862 862 862 82

5 1321 1319 1320 125

2' x 2' fixture with acrylic lens. Ballast: ICN-2S24 Report is based on 1836 Lumens per lamp. Efficiency: 66.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600

15 825 824 825 233

2' x 2' fixture with acrylic lens. Ballast: ICN-2S-24 Report is based on 1800 Lumens per lamp. Efficiency: 70.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600

15 1267 1265 1265 358

25 760 758 758 350

25 1171 1168 1167 539

35 673 669 668 419

35 1040 1035 1030 648

45 656 560 556 432

45 878 870 862 671

55 440 435 427 388

55 691 681 667 608

65 303 298 287 293

65 482 473 454 466

75 160 162 144 168

75 264 263 237 273

85 48 51 37 56

85 82 87 65 94

90 33 34 20

90 49 51 30

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

ZONE LUMENS % LAMP % FIXT 00-030 665 18.1 27.4 00-040 1084 29.5 44.7 00-060 1904 51.9 78.6 00-090 2422 66.0 100.0 90-180 0000 0.0 000.0 00-180 2422 66.0 100.0

ZONE LUMENS % LAMP % FIXT 00-030 1022 18.9 27.0 00-040 1670 30.9 44.2 00-060 2950 54.6 78.0 00-090 3782 70.0 100.0 90-180 0000 0.0 000.0 00-180 3782 70.0 100.0

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

01 72 68 66 64 62 60 61 60 58 02 65 60 55 56 52 49 54 51 48 03 59 52 47 49 45 41 47 44 41 04 54 46 40 44 39 35 42 38 35 05 50 41 35 39 34 30 38 34 30 06 46 37 31 35 30 27 34 30 26 07 43 34 28 32 27 24 31 27 23 08 40 31 25 29 25 21 29 24 21 09 37 28 23 27 22 19 26 22 19 10 35 26 21 25 20 17 24 20 17

01 76 72 69 68 66 63 65 63 61 02 69 63 58 59 55 52 57 54 51 03 63 55 49 52 47 44 50 46 43 04 57 49 43 46 41 37 45 40 37 05 53 44 37 41 36 32 40 35 32 06 49 39 33 37 32 28 36 31 28 07 45 36 29 34 29 25 33 28 25 08 42 33 27 31 26 22 30 25 22 09 39 30 24 29 24 20 28 23 20 10 37 28 22 26 22 18 26 21 18

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2568. 2545. 2527. 55 2432. 2404. 2360. 65 2222. 2185. 2105. 75 1826. 1849. 1643. 85 1324. 1407. 1021.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3991. 3954. 3918. 55 3819. 3764. 3686. 65 3535. 3469. 3330. 75 3013. 3001. 2705. 85 2263. 2400. 1793.

Ordering Information Explanation of Catalog Number. Example: FRS2GFW224UNVPG

S

G

F

W

Body Style:

Ceiling TypeG = Standard Grid
LensF = Frost White

Reflector:

Lamp Quantity 2=2 Lamp 3=3 Lamp

Lamp(By Others) 24 =T5HO 24w (Nominal 24")
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog
no., ie(A)

Ballast Type:

FR Standard FRX

FY For NYC Code – I.B.E.W. Manufactured

FN For NYC Code – Local 3 Manufactured

Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.

Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA30-10.

Specifications (continuned) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Specifications Performance: In an installation of 2 lamp 24W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .68. To reduce glare the average brightness at 65° shall not exceed 2222 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.6%. Lamp Shield: Frost white DR acrylic lens. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating.

Job Information Type:

  • For Factory Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> © 2008 a Philips Group Section 5/Folio MA10-11

Lightolier is a Philips group brand

Show 8 more labels / short text on this page
FRX Architectural · Fixture · S = Static · Width · White · Recessed Fluorescent · Acrylic Lens · 5½" Deep Body
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier FRS2GFW224について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier FRS2GFW224に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier FRS2GFW224 取扱説明書(PDF)

2 ページ·95 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…