
Page 1 of 2 Architectural Recessed Fluorescent 2' x 2' with Frost White Acrylic Lens, 2 or 3 Lamp T5HO




2" max.
2" max.
23-7/8" (606mm) Square Lens 13/16" (21mm)
24" (610mm)
5" (127mm)
G G
exposed T-grid ceiling.


Drywall Kit (See Options)
2" X 2-1/2" Access Plate with (2) 7/8" (73mm) Dia. KO’s
Drywall Kit, Catalog Number: FK92X2.

Job Information Type:
Job Name:
Expample of pattern mounting
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Architectural Recessed Fluorescent 2' x 2' with Frost White Acrylic Lens, 2 or 3 Lamp T5HO
Model No. FRS2GFW224UNVPG LER = FP - 42.0 IW - 50.8 BF - 0.88 Comparative yearly lighting energy cost per
Model No. FRS2GFW324UNVPG LER = FP - 48.3 IW - 78.3 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $5.71
1000 lumens = $4.97


0 869 869 869
0 1328 1328 1328
5 862 862 862 82
5 1321 1319 1320 125
2' x 2' fixture with acrylic lens. Ballast: ICN-2S24 Report is based on 1836 Lumens per lamp. Efficiency: 66.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
15 825 824 825 233
2' x 2' fixture with acrylic lens. Ballast: ICN-2S-24 Report is based on 1800 Lumens per lamp. Efficiency: 70.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 21.600 21.600
15 1267 1265 1265 358
25 760 758 758 350
25 1171 1168 1167 539
35 673 669 668 419
35 1040 1035 1030 648
45 656 560 556 432
45 878 870 862 671
55 440 435 427 388
55 691 681 667 608
65 303 298 287 293
65 482 473 454 466
75 160 162 144 168
75 264 263 237 273
85 48 51 37 56
85 82 87 65 94
90 33 34 20
90 49 51 30
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONE LUMENS % LAMP % FIXT 00-030 665 18.1 27.4 00-040 1084 29.5 44.7 00-060 1904 51.9 78.6 00-090 2422 66.0 100.0 90-180 0000 0.0 000.0 00-180 2422 66.0 100.0
ZONE LUMENS % LAMP % FIXT 00-030 1022 18.9 27.0 00-040 1670 30.9 44.2 00-060 2950 54.6 78.0 00-090 3782 70.0 100.0 90-180 0000 0.0 000.0 00-180 3782 70.0 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 72 68 66 64 62 60 61 60 58 02 65 60 55 56 52 49 54 51 48 03 59 52 47 49 45 41 47 44 41 04 54 46 40 44 39 35 42 38 35 05 50 41 35 39 34 30 38 34 30 06 46 37 31 35 30 27 34 30 26 07 43 34 28 32 27 24 31 27 23 08 40 31 25 29 25 21 29 24 21 09 37 28 23 27 22 19 26 22 19 10 35 26 21 25 20 17 24 20 17
01 76 72 69 68 66 63 65 63 61 02 69 63 58 59 55 52 57 54 51 03 63 55 49 52 47 44 50 46 43 04 57 49 43 46 41 37 45 40 37 05 53 44 37 41 36 32 40 35 32 06 49 39 33 37 32 28 36 31 28 07 45 36 29 34 29 25 33 28 25 08 42 33 27 31 26 22 30 25 22 09 39 30 24 29 24 20 28 23 20 10 37 28 22 26 22 18 26 21 18
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2568. 2545. 2527. 55 2432. 2404. 2360. 65 2222. 2185. 2105. 75 1826. 1849. 1643. 85 1324. 1407. 1021.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3991. 3954. 3918. 55 3819. 3764. 3686. 65 3535. 3469. 3330. 75 3013. 3001. 2705. 85 2263. 2400. 1793.
S
G
F
W
Body Style:
Reflector:
Lamp Quantity 2=2 Lamp 3=3 Lamp
Ballast Type:
FY For NYC Code – I.B.E.W. Manufactured
FN For NYC Code – Local 3 Manufactured
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10 and OA30-10.
Specifications (continuned) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specifications Performance: In an installation of 2 lamp 24W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .68. To reduce glare the average brightness at 65° shall not exceed 2222 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.6%. Lamp Shield: Frost white DR acrylic lens. Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for rigidity with side rails hemmed over and housing ends turned-in for safe handling. Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel minimum 86% reflectance. Rust preventative undercoating.
この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。
ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。
最初の質問を投稿しましょう。他のユーザーや当チームが回答します。