Page 1 of 2 Pendant



Must Order Powerhead and Glass separately.

Labels cULus Listed. Suitable for Damp Locations.


Electrical Lampholders: Incandescent E11 Base, Porcelain, Plated Copper Alloy Screw Shell Compact Fluorescent: 13W Twin: 2GX7 Base, High Impact Thermoset Polymer with Brass Contacts. 13W Quad: G24Q-1 Base, High Impact Thermoset Polymer with Brass Contacts.
7 5/16" · Cable/Cord Track Mount

Page of 2 Pendant
Catalog No. FS03/FS01, 4-Pin Twin Tube, 800 Lumens.
CANDLEPOWER SUMMARY Angle Mean CP Angle Mean CP
ZONAL LUMENS AND PERCENTAGES
Zone Lumens 0-10 4.1 10-20 11.89 20-30 16.15 30-40 22.11 40-50 31.03 50-60 40.41 60-70 49.15 70-80 55.68 80-90 58.92 90-100 58.92 100-110 55.68 110-120 48.66 120-130 39.53 130-140 28.74 140-150 18.32 150-160 9.51 160-170 2.91 170-180 .29
Zone Lumens %Lamp %Fixt 0-30 32.14 4 5.8 0-40 54.24 6.8 9.8 0-60 125.68 15.7 22.8 0-90 289.44 36.2 52.4 90-120 163.26 20.4 29.6 90-130 202.8 25.4 36.7 90-150 249.85 31.2 36.7 90-180 262.55 32.8 47.6 0-180 551.99 69 100 ** Efficiency = 69% **
0 39 90 54 5 42 95 54 10 45 100 54 15 43 105 53 20 38 110 51 25 34 115 49 30 34 120 47 35 35 125 44 40 37 130 41 45 40 135 37 50 43 140 33 55 45 145 29 60 47 150 25 65 50 155 20 70 51 160 15 75 53 165 10 80 54 170 5 85 54 175 2 90 54 180 1
Luminaire Input Watts = 16
Report No. 3108FR
Catalog No. FS03Q/FS01Q, 13W 4-Pin Quad Tube, 900 Lumens.
COEFFICIENTS OF UTILIZATION Ceiling 80% 70% 50% 30% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
CANDLEPOWER SUMMARY Angle Mean CP Angle Mean CP
ZONAL LUMENS AND PERCENTAGES
Zone Lumens 0-10 4.96 10-20 10.5 20-30 13.06 30-40 18.89 40-50 27.06 50-60 35.81 60-70 43.7 70-80 49.73 80-90 52.51 90-100 53.33 100-110 49.99 110-120 44.19 120-130 35.6 130-140 26.11 140-150 16.58 150-160 8.29 160-170 2.51 170-180 .25
Zone Lumens %Lamp %Fixt 0-30 28.52 3.2 5.8 0-40 47.41 5.3 9.6 0-60 110.28 12.3 22.4 0-90 256.23 28.5 52 90-120 147.51 16.4 29.9 90-130 183.11 20.3 37.1 90-150 225.8 25.1 37.1 90-180 236.85 26.3 48 0-180 493.07 54.8 100 ** Efficiency = 54.8% **
0 54 90 49 5 54 95 49 10 48 100 48 15 43 105 47 20 37 110 46 25 28 115 45 30 28 120 42 35 30 125 40 40 32 130 37 45 35 135 34 50 37 140 30 55 40 145 26 60 42 150 22 65 44 155 18 70 46 160 13 75 47 165 8 80 48 170 4 85 48 175 2 90 49 180 1
0 59 55 55 46 46 39 39 28 1 51 47 44 41 43 38 36 32 30 26 18 2 45 40 35 31 36 29 30 24 24 20 13 3 41 34 29 25 31 23 26 19 21 16 10 4 37 30 24 20 27 19 22 16 18 13 8 5 34 26 21 17 24 16 20 13 16 11 6 6 31 23 18 15 21 13 18 11 14 9 5 7 28 21 16 13 19 12 16 10 13 8 5 8 26 19 14 11 17 10 14 9 12 7 4 9 25 17 13 10 16 9 13 8 11 6 4 10 23 16 11 9 14 8 12 7 10 5 3 Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 14
Report No. 3105FR
Catalog No. IS03/IS01, 50W T-4, 950 Lumens.
COEFFICIENTS OF UTILIZATION Ceiling 80% 70% 50% 30% Wall 70 50 30 10 50 10 50 10 50 10 0 RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
CANDLEPOWER SUMMARY Angle Mean CP Angle Mean CP
ZONAL LUMENS AND PERCENTAGES
Zone Lumens 0-10 8.06 10-20 6.98 20-30 8.18 30-40 12.83 40-50 18.63 50-60 24.81 60-70 30.42 70-80 34.52 80-90 36.01 90-100 36.82 100-110 34.52 110-120 30.42 120-130 24.26 130-140 17.85 140-150 11.61 150-160 5.93 160-170 1.53 170-180 .1
Zone Lumens %Lamp %Fixt 0-30 23.21 2.4 6.8 0-40 36.04 3.8 10.5 0-60 79.48 8.4 23.1 0-90 180.42 19 52.5 90-120 101.76 10.7 29.6 90-130 126.02 13.3 36.7 90-150 155.48 16.4 36.7 90-180 163.04 17.2 47.5 0-180 343.46 36.2 100 ** Efficiency = 36.2% **
0 158 90 33 5 104 95 34 10 43 100 33 15 23 105 33 20 18 110 32 25 17 115 31 30 19 120 29 35 20 125 27 40 22 130 25 45 24 135 23 50 26 140 21 55 28 145 18 60 29 150 16 65 31 155 13 70 32 160 9 75 33 165 5 80 33 170 1 85 33 175 1 90 33 180 1
0 39 36 36 31 31 26 26 19 1 34 31 29 27 29 25 24 21 20 18 12 2 30 26 23 21 24 19 20 16 16 13 9 3 27 23 19 17 21 15 17 13 14 11 7 4 25 20 16 14 18 13 15 11 12 9 5 5 22 18 14 12 16 11 13 9 11 7 5 6 21 16 12 10 14 9 12 8 10 6 4 7 19 14 11 9 13 8 11 7 9 6 3 8 18 13 10 8 12 7 10 6 8 5 3 9 16 12 9 7 11 6 9 5 7 4 3 10 15 11 8 6 10 6 8 5 7 4 2 Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 50
Report No. 3101FR