Page 1 of 2 4 1/2" Aperture A19 Lamp Horizontal

Molded Trim Ring Flush Trim (Molded trim ring removed)
Overlap Self-Flange Matte White or Polished
Ceiling Cutout: 5 1/16" Dia.

Features 1. Socket Cup: Heat-dissipating die-formed aluminum contains medium base porcelain socket with nickel plated screw shell wired with No. 18 SF1 leads to J-Box. Installs on reflector with positive position locking springs to assure proper optical alignment of lamp to reflector—attached without tools. 2. Mounting Brackets: Adjust vertically from inside of fixture. Durable 16 ga. steel construction. Use with standard 3/4" or 1 1/2" lathing channels (by oth- ers), or Lightolier accessory mounting bars. 3. Retaining Springs: Precision-tooled springs secure reflector to mounting frame for quick tool-less installation. 4. Reflector: 16 ga. Specular Alzak® aluminum, 50° visual cut-off to lamp and lamp image. Available with white or polished flange, or with removable white molded trim ring (field paintable). 5. Junction Box: 14 ga. steel, 4" x 4" x 2" box allows inspection from below. 6. Thermal Protector: Meets NEC and UL requirements. Insulation must be kept 3" away from fixture sides and wiring compartments and must not be placed above fixture in a manner which will entrap heat. 7. Mounting Frame: Die-cast aluminum suitable for dry or plaster ceilings. Provides flangeless trim in plaster ceiling.
Options & Accessories 18" Mounting Bars 1950 (set of 2) 27" Mounting Bars 1951 (set of 2) T-Bar Anchor Clips 1956 (set of 4, for 1950 & 1951 bars) Existing Ceiling Clips 7998 (set of 2) Sloped Ceiling Adapters See SCA specification sheet Step Down Transformer 7997 (see separate specification sheet) Chicago Air Plenum LC (add suffix to Frame-in Kit, requires access
Electrical UL Listed for maximum of 8 No. 12, 75°C through branch circuit supply conduc- tors, or 60°C conductors for end of run.
Labels UL Listed for damp locations, I.B.E.W.
Alzak® is a registered trademark of ALCOA.

Other Reflector Finish Options Comfort Clear Diffuse CCD Specular Gold GD White WH
Flange Options White W Polished Flange P Flangeless Leave Blank (molded trim ring)

Page 2 of 2 4 1/2" Aperture A19 Lamp Horizontal
100 Watt A-19 1750 Lumens Per Lamp
RCR = 10 (Rm. Width - Mtg. Ht. above work plane) RCR = 5 (Rm. Width - 2 x Mtg. Ht. above work plane) RCR = 1 (Rm. Width - 10 x Mtg. Ht. above work plane)
80% Ceiling; 50% Walls; 20% Floor Room Surface Reflectances:
105 90 75 60 45 30 15
Area Per Fixture In Square Feet
10 9 8 7 6 5 3 4
Center To Center Distance Of Fixtures In Feet
Use quick calculator chart to determine spacing of luminaires for desired level of illu- mination. Conversion Factor: 100W A19 (gold): F.C. x 0.90
Spacing Ratio= 1.1
Candlepower Summary
DEG CP ZONAL FLUX
0 559 13 5 575 43 10 641 83 15 769 135 20 852 177 25 775 165 30 507 114 35 307 89 40 245 91 45 259 95 50 120 9 55 6 1 60 2 0 65 2 1 70 0 0 75 2 1 80 1 1 85 0 1
ZONE LUMENS LAMP FIXT
0- 30 617 35.4 60.6
0- 40 819 47.1 80.5
0- 60 1014 58.3 99.6
0- 90 1018 58.5 100.0
90- 180 0 0.0 0.0
0- 180 1018 58.5 100.0
Total Luminaire Efficiency = 58.5 % CIE Type - Direct
80 70 50 30 10 0
1 2 3 4 5 6 7 8 9 10
.65 .63 .62 .64 .62 .61 .61 .60 .59 .59 .58 .58 .57 .56 .56 .55 .61 .59 .57 .60 .58 .56 .58 .56 .55 .56 .55 .54 .55 .54 .53 .52 .57 .54 .52 .56 .54 .52 .55 .53 .51 .53 .52 .50 .52 .51 .49 .48 .53 .50 .48 .53 .50 .48 .52 .49 .47 .50 .48 .47 .49 .48 .46 .45 .50 .47 .44 .50 .47 .44 .49 .46 .44 .48 .45 .43 .47 .45 .43 .42 .47 .44 .41 .47 .43 .41 .46 .43 .41 .45 .42 .41 .44 .42 .40 .39 .44 .40 .38 .43 .40 .38 .43 .40 .38 .42 .39 .38 .41 .39 .37 .36 .41 .37 .35 .41 .37 .35 .40 .37 .35 .39 .37 .35 .39 .36 .35 .34 .38 .35 .32 .38 .34 .32 .37 .34 .32 .37 .34 .32 .36 .34 .32 .31 .36 .32 .30 .35 .32 .30 .35 .32 .30 .34 .31 .30 .34 .31 .29 .29
20% Floor Cavity Reflectance Conversion Factor: For 100W A19 units with gold reflector, multiply C.U.’s by 0.9.
Initial Footcandles · Room Cavity Ratio