JA
Lightolier logo
公式取扱説明書

Lightolier GSW SERIES

2 ページ·91 KB·インテリア家具・調度品·PDF·EN
Lightolier GSW SERIES
目次 10セクション Guardsman Vandal Resistant GSW SERIES · Dimensions · For Continuous Row Mounting · Job Information Type: · … 表示非表示
Page 1 of the Lightolier GSW SERIES user manual — For Continuous Row Mounting
1ページ · クリックして拡大
1ページ

Guardsman Vandal Resistant GSW SERIES

  • Page 1 of 2 Ceiling or Wall Mounted Fluorescent 6" Width, 3-7/8" Deep, 24" or 48" Nominal Length, 1 or 2 Lamp T8 Features
  • Excellent for locations where vandal resistance is required, areas such as hallways, stairwells, locker rooms, parking garages and psychiatric hospitals.
  • For ceiling or wall mounted applications.
  • Can be vertically or horizontally mounted on wall.
  • 20 gauge cold rolled steel, post painted, baked white enamel housing.
  • 18 gauge cold rolled steel post painted baked white enamel end caps, standard.
  • Linear prismatic lens 50% DR (impact resistant) and 50% standard acrylic with nominal thickness of 1/8", withstands 70 ft lbs impact without breaking.
  • Tamper resistant holt head screws secure ends to housing.
  • Only 3-7/8" deep, meets American with Disabilities Act for wall mounted fixtures.
  • Nominal 2' and 4' lengths.
  • 73.9% efficient (T8 lamps).
Lightolier GSW SERIES — Guardsman Vandal Resistant GSW SERIES diagram (page 1)
図 1 · Guardsman Vandal Resistant GSW SERIES

Dimensions

7/8" dia. K.O. (2) 9/32" hole (2)

Lightolier GSW SERIES — Dimensions diagram (page 1)
図 2 · Dimensions
Lightolier GSW SERIES — Dimensions diagram (page 1)
図 3 · Dimensions

4" (102mm) 6" (152mm)

7/8" dia. K.O. (3) 9/32" hole (2) 1-7/8" dia. K.O.

Lightolier GSW SERIES — Dimensions diagram (page 1)
図 4 · Dimensions
Lightolier GSW SERIES — Dimensions diagram (page 1)
図 5 · Dimensions

End Cap End Cap

Required to space fixtures apart so ends

can be removed or

installed.

For Continuous Row Mounting

Job Information Type:

Job Name:

C at. N o.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2003 Lightolier Section 6A/Folio P10-62 9/03
Show 11 more labels / short text on this page
6" (152mm) · 23-15/16" (608mm) · 3-7/8" (98mm) · Threaded · 4" (102mm) · Nipple · Nut Nut · 6" (152mm) · 24" (610mm) · 48" (1219mm) · Nut
Page 2 of the Lightolier GSW SERIES user manual — Job Inform ation Type:
2ページ · クリックして拡大
2ページ

Guardsman Vandal Resistant GSW SERIES

Page 1 of 2 Ceiling or Wall Mounted Fluorescent 6" Width, 3-7/8" Deep, 24" or 48" Nominal Length, 1 or 2 Lamp T8

Photometry Model No. GSW4232120SO

LER = FP - 62.9 IW - 59.1 BF - 0.88 Comparative yearly lighting energy cost per 1000 lumens = $4.06

Lightolier GSW SERIES — Photometry Model No. GSW4232120SO diagram (page 2)
図 6 · Photometry Model No. GSW4232120SO

coefficients of utilization — zonal cavity method

RF20 20 20 RC80 50 30 RW70 50 30 50 30 10 50 30 10 1 2 3 ratio 4 cavity 5 6 7 room 8 9 1081 76 73 67 65 62 62 60 58 73 66 61 58 54 51 54 51 48 66 58 51 51 46 42 47 43 40 61 51 44 46 40 36 42 38 34 56 46 39 41 35 31 38 33 29 51 41 34 37 31 27 34 29 26 48 37 30 33 28 24 31 26 23 44 34 27 31 25 21 29 24 20 41 31 25 28 23 19 26 22 18 39 29 23 26 21 17 24 20 17

G97001 GSW4232120SO

ADVANCE RIC2S32TP SOLID STATE OCTRON BALLAST

20 20 20 30 20 40 20 6040 47 58 69 35 40 46 56 33 36 41 47 32 35 38 4230 39 53 66 20 27 35 48 15 20 26 35 11 15 19 25 30 20 30 30 30 40 30 60 30 8038 45 55 66 32 37 43 52 30 33 38 43 29 32 34 39 29 31 33 37 e32 40 51 64 22 27 35 46 16 20 26 33 12 15 19 25 10 12 15 20 e ee 40 20 40 30 40 40 40 60 40 80 40 100minaries lengthwis38 45 53 64 31 36 42 51 29 32 36 42 27 30 32 37 27 30 31 35 27 30 31 34minaries crosswis34 42 52 63 24 29 36 46 18 22 26 33 13 16 19 25 10 13 15 20 9 11 13 16 60 30 60 40 60 60 60 80 60 10031 36 41 49 lu 28 31 35 41 26 29 31 36 25 28 29 33 25 27 29 32lu25 31 37 47 lu 19 23 27 34 14 17 20 25 11 14 16 20 9 11 13 17lu 100 40 100 60 100 80 100 10029 31 34 40 25 28 30 34 24 26 28 32 23 26 27 3023 27 30 37 16 20 22 27 13 16 18 22 11 13 15 18

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.

Ordering Information Explanation of Catalog Number. Example: GSW4232120SOEM

GSW

GSWGuardsman Surface/Wall Vandal Resistant

1 or 2 Lamps Fixture Length: 2 = 24" 4 = 48"

Lamp Quantity:

Lamp(By Others) 17 = T8 2' Length 32 = T8 4' Length
Voltage120 or 277 Ballast Type:
OptionsAdd appropriate suffix to catalog

no, ie(EM)

Options & Accessories In-Line Fusing: Internal fast-blow fusing. Suffix: GLR.

Specifications (continued) Finish: Chassis exterior–post painted white baked acrylic enamel. End Caps and Cover–Post painted baked white enamel. Phosphate undercoating. Refractor: Low brightness linear prismatic lens, 50% DR (impact resistant) and 50% standard acrylic, 1/8" thickness, withstands 70 ft lbs impact. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc listed.

Internal slow-blow fusing. Suffix: GMF. Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. Suffix: R. One per ballast. Suffix: B. Emergency Power Pack: Factory installed emergency power pack includes charger and inverter concealed in fixture channel. Upon loss of AC power, oper- ates one lamp at reduced light. Suffix: EM. Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface. Catalog Number: ASC6 CSP (6") ASC12 CSP (12") ASC18 CSP (18") ASC24 CSP (24")

Job Inform ation Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. Copyright 2003 Lightolier Section 6A/Folio P10-62

Specifications Materials: Chassis parts are die-formed 20 gauge cold rolled steel. Refractor–one-piece 50% DR virgin acrylic. End Caps–18 gauge cold rolled steel.

Fluorescent

情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier GSW SERIESについて質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier GSW SERIESに関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier GSW SERIES 取扱説明書(PDF)

2 ページ·91 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…