Page 1 of 2 VANDAL RESISTANT, 1'x4' RECESSED FLUORESCENT, STATIC, 1 OR 2 LAMP, T8 OR T12

exposed T-grid ceiling (with flat steel frame) F G plaster ceiling/flanged. (with regressed aluminum frame)



1/4" max.
1-1/2" max.
drywall kit (see options) gasketing detail


Drywall Kit (See Options)
Gasketing (Close Cell Neoprene)
Ceiling Opening 12-5/16" x 48-5/16"
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 VANDAL RESISTANT, 1'x4' RECESSED FLUORESCENT, STATIC, 1 OR 2 LAMP, T8 OR T12
LER = FL - 48.3 IW - 80.0 BF - 0.95 Comparative yearly lighting energy cost per 1000 lumens = $5.00

coefficients of utilization — zonal cavity method
GV
S
FS
VK
FIXTURE
WIDTH
(lay-in T bar) F=Flanged
BALLAST TYPE: 2 Lamp Mag. T12 LE
LAMP/ FIXTURE LENGTH:
Z spline and plaster frame
32=T8 34=T12 (Nominal 48")
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES SCREWDRIVER: For holt head screw. Order Catalog Number LP156737. ACCESS PLATE: Top wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP CSP. CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are required between fixtures. Order Catalog Number: 1FC TRIM (each joint). PLASTER FRAMES: F type fixtures do not include plaster frames. For individ- ual or continuous mounting, specify PF14 universal frame per fixture. ELECTRICAL/WIRING OPTIONS: Consult factory. SEISMIC HOLD-DOWN CLIP: For type G troffers. SUFFIX: 2HD. FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. DRYWALL KIT: Order Catalog Number: FK91X4.
SPECIFICATIONS (continued) lengthwise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2130 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.4%. MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing is contoured for rigidity with all edges turned up for safe handling. FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENS: (VK) prismatic lens is 3/16" thick, pattern 12, minimum impact strength, 130 foot pounds. ELECTRICAL: Thermally protected class "P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
Request Folio OA30-10. CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .66. To prevent glare the VCP shall not be less than 44 either
frame · (overlap) · Prismatic Lens (standard)