Page 1 of 2 VANDAL RESISTANT, 2'x2' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12

exposed T-grid ceiling (with flat steel frame) F G plaster ceiling/flanged. (with regressed aluminum frame)



1/4" max.
1-1/8" min. 3-3/4" max.
1-1/2" max.

drywall kit (see options) gasketing detail


Drywall Kit (See Options)
Gasketing (Close Cell Neoprene)
Ceiling Opening 24-5/16" x 24-5/16"
2"x 2-1/2" access plate with two K.O.s (7/8" dia.)


Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 VANDAL RESISTANT, 2'x2' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12
LER = FL - 58.9 IW - 56.4 BF - 0.87 Comparative yearly lighting energy cost per 1000 lumens = $4.07
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 76 73 71 69 67 65 66 64 63 2 70 65 61 61 58 55 59 56 54 3 65 58 53 55 51 47 53 50 47 4 60 52 46 49 45 41 48 44 41 5 55 47 41 45 40 36 43 39 36 6 51 43 37 41 36 32 40 35 32 7 48 39 33 37 32 29 36 32 29 8 44 36 30 34 29 26 33 29 26 9 42 33 27 32 27 24 31 27 23 10 39 30 25 29 25 22 29 24 21 visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 65 69 76 81 64 68 74 79 20 30 58 62 68 73 56 60 66 71 20 40 54 58 63 66 51 55 61 65 20 60 51 55 58 62 46 51 55 59 30 20 66 70 75 80 65 69 74 78 30 30 58 62 67 71 56 60 66 69 30 40 54 57 61 64 50 54 59 63 30 60 50 53 56 59 46 50 53 57 30 80 49 51 53 56 44 47 49 53 40 20 67 71 76 80 66 71 75 79 40 30 59 63 67 71 57 62 66 70 40 40 54 57 61 64 51 55 59 63 40 60 50 53 55 58 46 50 53 57 40 80 49 51 52 55 44 47 49 52 40 100 48 50 50 53 43 45 46 50 60 30 60 64 67 71 58 63 67 70 60 40 55 58 61 64 52 56 59 63 60 60 51 53 55 58 47 50 52 56 60 80 49 51 51 54 44 47 48 52 60 100 48 49 49 52 43 45 45 49 100 40 57 60 62 66 56 59 61 65 100 60 53 55 56 59 50 53 54 58 100 80 50 52 52 55 47 49 50 53 100 100 49 50 49 52 45 46 46 48
GV
S
FS
VK
FIXTURE
WIDTH
2=2 Lamp 3=3 Lamp (Not with 6" spacing) 4=4 Lamp (T8, 2' Lamp Only)LAMP/
BALLAST TYPE: 1-2 Lamp Mag. T12 LE
FIXTURE LENGTH: 6U=6"U Lamp T8 or T12 2U=T8, 1-5/8" U Lamp FT=Twin Tube T5 17=T8, 2' Lamp (Nominal 24")
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES SCREWDRIVER: For holt head screw. Order Catalog Number LP156737. PLASTER FRAME: Catalog Number PF22. CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. ELECTRICAL/WIRING OPTIONS: Consult factory. DRYWALL KIT: Order Catalog Number: FK92X2.
SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe han- dling. FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENS: (VK) prismatic lens is 3/16" thick, pattern 12, minimum impact strength, 130 foot pounds. ELECTRICAL: Thermally protected class "P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
Request Folio OA30-10. CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS PERFORMANCE: In an installation of 2 lamp 31W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .73. To prevent glare the VCP shall be not less than 40 either length- wise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2144 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.0%.