Page 1 of 2 VANDAL RESISTANT, 2'x4' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12

exposed T-grid ceiling (with flat aluminum frame) F G plaster ceiling/flanged.



1/4" max.
24-1/8" 1-1/8" min. 3-3/4" max.
1-1/2" max.
2" x 2-1/2" access plate with two K.O.s (7/8" dia.)

drywall kit (see options)


Drywall Kit (See Options)
Gasketing (Close Cell Neoprene)
Ceiling Opening 24-5/16" x 48-5/16"


Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 VANDAL RESISTANT, 2'x4' RECESSED FLUORESCENT, STATIC, 2, 3 OR 4 LAMP, T8 OR T12
LER = FL - 69.0 IW - 105 BF - 0.86 Comparative yearly lighting energy cost per 1000 lumens = $3.48
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF 20 20 20 RC 80 50 30 RW 70 50 30 50 30 10 50 30 10 1 82 79 76 74 72 70 71 69 68 2 75 70 65 66 62 59 63 60 58 3 69 62 56 59 54 51 57 53 50 4 64 56 50 53 48 44 51 47 43 5 59 50 44 48 43 39 46 42 38 6 55 45 39 43 38 34 42 38 34 7 51 41 35 40 34 31 39 34 30 8 47 38 32 36 31 28 36 31 27 9 44 35 29 34 29 25 33 28 25 10 42 32 27 31 26 23 31 26 23 visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0 20 20 63 67 74 79 62 66 73 78 20 30 56 60 65 70 54 59 64 69 20 40 52 55 60 64 49 53 59 63 20 60 49 52 55 59 45 49 53 58 30 20 63 68 73 78 63 67 72 77 30 30 56 60 64 69 54 59 64 68 30 40 51 55 58 62 49 53 57 61 30 60 48 51 53 57 44 48 51 55 30 80 46 49 50 54 42 45 48 52 40 20 65 69 74 78 64 69 73 77 40 30 57 61 65 68 55 60 64 68 40 40 52 55 59 62 50 53 57 61 40 60 48 51 53 56 45 48 51 55 40 80 46 49 49 53 43 45 47 51 40 100 46 48 48 50 42 44 45 48 60 30 57 61 65 69 57 61 65 68 60 40 52 55 58 62 51 54 58 61 60 60 48 51 52 56 46 48 51 54 60 80 46 48 49 52 43 45 46 50 60 100 46 47 47 49 42 43 44 47 100 40 55 58 60 64 54 57 60 63 100 60 51 52 53 57 49 51 52 56 100 80 48 50 50 53 46 47 48 51 100 100 47 48 47 50 44 45 45 47
GV
S
FS
VK
FIXTURE
WIDTH
2=2 Lamp 3=3 Lamp 4=4 Lamp
BALLAST TYPE: 1 & 2 Lamp Mag. T12 LE 2-2 Lamp Mag. T12 LE
LAMP/ FIXTURE LENGTH:
32=T8 34=T12 (Nominal 48")
Other dimming options. Consult factory.
OPTIONS & ACCESSORIES SCREWDRIVER: For holt head screw. Order Catalog Number LP156737. PLASTER FRAME: Catalog Number PF24. CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges are required between fixtures. Order Catalog Number: S2FCTRIM (each joint). RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture standard. SUFFIX: RF. FUSING: Internal fast-blow fusing. SUFFIX: GLR. Internal slow-blow fusing. SUFFIX: GMF. ELECTRICAL/WIRING OPTIONS: Consult factory. DRYWALL KIT: Order Catalog Number: FK92X4.
SPECIFICATIONS (continued) MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side rails hemmed over and housing ends turned-in for safe handling. FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester enamel minimum 86% reflectance. Phosphate undercoating. LENS: (VK) prismatic lens is 3/16" thick pattern 12, minimum impact strength, 130 foot pounds. ELECTRICAL: Thermally protected class "P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. LABELS: I.B.E.W./UL and C-UL.
(Request Folio OA30-10). CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS PERFORMANCE: In an installation of 4 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .79. To prevent glare the VCP shall be not less than 46 either length- wise or crosswise (at 100fc level) and the average brightness at 65° shall not exceed 2321 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 66.8%.