Page 1 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens




Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others
exposed slot t-grid ceiling
1-1/2" x 1-1/2" Access Plate With 7/8" dia. K.O.



7/8" Dia. K.O.
fully enclosed lamp compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Model No. H9S1GLR128UNVPG LER = FP - 72.6 IW - 31.83 BF - 1.0 Comparative yearly lighting energy cost per
Model No. H9S1GLR228UNVPG LER = FP - 77.2 IW - 63.31 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $3.30
1000 lumens = $3.11


0 832 832 832
0 1661 1661 1661
5 821 841 860 81
5 1643 1659 1678 158
prismatic lens. Ballast: QTP 2x28 T5-UNV-PSN Report is based on 2750 Lumens per lamp. Efficiency: 84.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.760 11.760
15 796 862 879 240
prismatic lens. Ballast: QTP2X28T5/UNV Report is based on 2750 Lumens per lamp. Efficiency: 88.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.760 11.760
15 1581 1654 1725 468
25 752 797 798 364
25 1466 1621 1692 737
35 690 680 653 423
35 1303 1470 1512 902
45 597 528 560 425
45 1088 1217 1236 922
55 441 406 420 366
55 823 913 889 793
65 261 263 266 261
65 537 590 558 569
75 117 127 124 134
75 256 283 250 291
85 17 18 18 22
85 38 42 38 50
90 2 2 2
90 3 4 3
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 685 24.9 29.6 00-040 1108 40.3 47.8 00-060 1899 69.1 82.0 00-090 2316 84.2 100.0 90-180 0000 0.0 000.0 00-180 2316 84.2 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 1364 24.8 27.9 00-040 2266 41.2 46.3 00-060 3981 72.4 81.4 00-090 4891 88.9 100.0 90-180 0000 0.0 000.0 00-180 4891 88.9 100.0
01 92 88 85 83 80 78 80 78 76 02 84 77 72 73 69 65 70 67 63 03 77 68 62 64 59 55 62 58 54 04 70 61 53 57 52 47 55 50 46 05 65 54 47 52 45 41 50 45 40 06 6- 49 42 47 40 36 45 40 35 07 56 44 37 42 36 32 41 36 32 08 52 41 34 39 33 28 38 32 28 09 48 37 30 36 30 26 35 29 26 10 45 34 28 33 27 23 32 27 23
01 97 93 89 87 85 82 84 82 80 02 89 81 75 77 72 68 74 70 67 03 81 72 64 68 62 57 65 60 56 04 74 63 56 60 54 49 58 53 48 05 68 57 49 54 47 42 52 46 42 06 63 51 43 49 42 37 47 41 37 07 58 46 38 44 37 33 43 37 32 08 54 42 35 40 34 29 39 33 29 09 51 39 31 37 31 26 36 30 26 10 47 36 29 34 28 24 33 28 24
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2329. 2060. 2185. 55 2121. 1953. 2020. 65 1794. 1717. 1736. 75 1247. 1354. 1322. 85 538. 570. 570.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4245. 4748. 4822. 55 3958. 4391. 4276. 65 3505. 3851. 3542. 75 2729. 3046. 2665. 85 1203. 1329. 1203.
S
G
R
Body Style:
Ceiling Type:
Reflector:
Lamp Quantity 1=1 Lamp 2=2 Lamp
Fits both Standard Grid
Ballast Type:
HY For NYC Code – I.B.E.W. Manufactured
HN For NYC Code – Local 3 Manufactured
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK91X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .93. To reduce glare the average brightness at 65° shall not exceed 3851 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.1%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.