Page 1 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens




Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others
exposed slot t-grid ceiling
1-1/2" x 1-1/2" Access Plate With 7/8" dia. K.O.



7/8" Dia. K.O.
2 earthquake clips standard
fully enclosed lamp compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Model No. H9S1GLR154UNVPG LER = FP - 56.9 IW - 61.0 BF - 1.0 Comparative yearly lighting energy cost per
Model No. H9S1GLR254UNVPG LER = FP - 62.9 IW - 109.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $4.21
1000 lumens = $3.82


Report Number: G2006142 Catalog Number: H9S1GLR154UNVPG Lamps: F54 T5 HO Luminaire: HP90 1' x 4' with linear
Report Number: G2006165 Catalog Number: H9S1GLR254UNVPG Lamps: F28 T5 HO Luminaire: HP90 1' x 4' with linear
0 1303 1303 1303
0 2472 2472 2472
5 1288 1304 1319 124
5 2443 2467 2491 236
prismatic lens. Ballast: Advance ICN-2S54-90C Report is based on 4400 Lumens per lamp. Efficiency: 79.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.760 11.760
15 1249 1286 1305 363
prismatic lens. Ballast: B254I UNV-E Report is based on 4400 Lumens per lamp. Efficiency: 77.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 10.800
15 2358 2452 2533 693
25 1175 1202 1207 552
25 2189 2362 2406 1073
35 1059 1036 1023 649
35 1936 2082 2071 1282
45 880 819 850 647
45 1601 1662 1641 1272
55 633 609 632 548
55 1180 1203 1188 1071
65 365 369 383 373
65 716 746 766 748
75 160 179 178 189
75 324 375 377 394
85 29 31 28 37
85 63 78 74 90
90 2 2 2
90 15 15 15
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 1039 23.6 29.8 00-040 1688 38.4 48.5 00-060 2883 65.5 82.8 00-090 3481 79.1 100.0 90-180 0000 0.0 000.0 00-180 3481 79.1 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 2002 22.7 29.2 00-040 3283 37.3 47.9 00-060 5626 63.9 82.0 00-090 6858 77.9 100.0 90-180 0000 0.0 000.0 00-180 6858 77.9 100.0
01 87 83 80 78 76 73 75 73 71 02 79 73 68 69 65 61 66 63 60 03 72 64 58 61 56 52 59 54 51 04 66 57 51 54 49 44 52 48 44 05 61 51 44 49 43 39 47 42 38 06 57 46 39 44 38 34 43 38 34 07 52 42 35 40 34 30 39 34 30 08 49 38 32 37 31 27 36 31 27 09 46 35 29 34 28 34 33 28 24 10 43 33 26 31 26 22 31 26 22
01 85 82 78 77 74 72 74 72 70 02 78 72 66 67 63 60 65 62 59 03 71 63 57 60 55 51 57 53 50 04 65 56 49 53 48 43 51 47 43 05 60 50 43 48 42 38 46 41 37 06 55 45 38 43 37 33 42 37 33 07 51 41 34 39 34 29 38 33 29 08 48 38 31 36 30 26 35 30 26 09 45 34 28 33 28 24 32 27 24 10 42 32 26 31 25 21 30 25 21
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3483. 3195. 3316. 55 3044. 2929. 3040. 65 2383. 2408. 2500. 75 1705. 1908. 1897. 85 918. 981. 886.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 6941. 7205. 7114. 55 6307. 6430. 6349. 65 5194. 5411. 5556. 75 3838. 4442. 4465. 85 2216. 2743. 2603.
S
G
R
Body Style:
Ceiling Type:
Reflector:
Lamp Quantity 1=1 Lamp 2=2 Lamp
Fits both Standard Grid
Ballast Type:
HY For NYC Code – I.B.E.W. Manufactured
HN For NYC Code – Local 3 Manufactured
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK91X4. Electrical Wiring Options: Consult factory. Optional motion or light sensor: Request Folio OA20-10.
Specifications Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .83. To reduce glare the average brightness at 65° shall not exceed 2500 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 70.2%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Reflector – low iridescence specular aluminum 95% reflectance. Phosphate undercoating.