Page 1 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens




Exposed T-bar by others
Exposed T-bar by o hers
1-1/2" max.
Acoustical material by o hers
1-7/8" max.
Acoustical material by others

* For flush mounting when using 9/16" Exposed T-Grid ceiling system consult factory
exposed slot t-grid ceiling


2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
fully enclosed lamp compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Model No. H9S2GLR132UNVHI LER = FP - 74.8 IW - 26.66 BF - 0.88 Comparative yearly lighting ene gy cost per
Model No. H9S2GLR232UNVHI LER = FP - 73.6 IW - 55.1 BF - 0.88 Comparative yearly lighting ene gy cost per
CANDELA DISTRIBUTION
1000 lumens = $3.21
1000 lumens = $3.26


Report Number: G2007123 Catalog Number: H9S2GLR132UNVHI Lamps: (1) F28 T8 Luminaire: HP90 2' x 4' with linear
Report Number: G2007007 Catalog Number: H9S2GLR232UNVHI Lamps: (2) F28 T8 Luminaire: HP90 2' x 4' with linear
0 659 659 659
0 1481 1481 1481
5 654 658 660 63
5 1471 1474 1478 140
prismatic lens. Ballast: GE-132-MAX-N/ULTRA Report is based on 2725 Lumens per lamp. Efficiency: 80% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800
15 628 643 655 182
prismatic lens. Ballast: GE-232-MAX-N/ULTRA Report is based on 2725 Lumens per lamp. Efficiency: 84.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800
15 1421 1429 1446 404
25 578 612 641 282
25 1298 1344 1398 620
35 507 562 609 351
35 1131 1219 1301 763
45 415 495 562 380
45 921 1061 1175 814
55 306 415 497 365
55 673 872 1006 767
65 186 322 420 311
65 412 659 803 629
75 86 223 275 208
75 191 424 490 394
85 20 33 24 39
85 40 63 41 77
90 3 3 2
90 3 3 3
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
ZONAL LUMEN SUMMARY
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 526 19 3 24 1 0- 40 877 32 2 40 2 0- 60 1623 59 6 74.4 0- 90 2180 80 0 100 0 90-180-180 2180 80 0 100 0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 0- 30 1165 21.4 25 3 0- 40 1927 35.4 41 8 0- 60 3508 64.4 76 1 0- 90 4609 84 6 100 0 90-180-180 4609 84 6 100 0
1 86 82 79 77 74 72 74 72 70 2 78 71 65 67 62 58 64 60 57 3 71 62 55 58 53 48 56 51 47 4 64 54 47 51 45 40 49 44 40 5 59 48 41 46 39 35 44 39 34 6 54 43 36 41 35 30 40 34 30 7 50 39 32 37 31 26 36 30 26 8 47 36 29 34 28 24 33 27 23 9 44 33 26 31 25 21 30 25 21 10 41 30 24 29 23 19 28 23 19
1 92 87 84 82 79 76 79 76 74 2 83 76 70 71 66 62 68 64 61 3 75 66 59 62 56 52 60 55 51 4 69 58 50 55 49 44 53 47 43 5 63 52 44 49 42 38 47 42 37 6 58 47 39 44 38 33 43 37 32 7 54 42 34 40 34 29 39 33 29 8 50 38 31 37 30 26 36 30 25 9 47 35 28 34 27 23 33 27 23 10 44 32 26 31 25 21 30 25 21
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 789. 942. 1069. 55 718. 973. 1165. 65 592. 1025. 1337. 75 447. 1159. 1429. 85 309. 509. 370.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1891. 2179. 2413. 55 1704. 2208. 2574. 65 1416. 2264. 2759. 75 1072. 2379. 2749. 85 666. 1050. 683.
S
G
R
Body Style:
Ceiling Type:
Reflector:
Lamp Quantity 1=1 Lamp 2=2 Lamp
Fits both Standard Grid
Ballast Type:
HY For NYC Code – I B.E.W. Manufactured
HN For NYC Code – Local 3 Manufactu ed
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor. See Folio OA20-10.
Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .87. To reduce glare the average brightness at 65° shall not exceed 2759 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.7%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white polyester enamel. Cavity – baked white polyester enamel. Rust preventative undercoating. Reflector – low irides- cence specular aluminum 95% reflectance.