Page 1 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens




Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others

exposed slot t-grid ceiling



2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
fully enclosed lamp compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Model No. H9S2GLR154UNVPG LER = FP - 57.1 IW - 62.4 BF - 1.0 Comparative yearly lighting energy cost per
Model No. H9S2GLR254UNVPG LER = FP - 66.5 IW - 112.39 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $4.20
1000 lumens = $3.61


Report Number: G2006154 Catalog Number: H9S2GLR154UNVPG Lamps: F54 T5 HO Luminaire: HP90 2' x 4' with linear
Report Number: G2006118 Catalog Number: H9S2GLR254UNVPG Lamps: F54 T5 HO Luminaire: HP90 2' x 4' with linear
0 1393 1393 1393
0 2340 2340 2340
5 1374 1395 1411 133
5 2320 2339 2354 223
prismatic lens. Ballast: Advance ICN-2S54 UNV PG Report is based on 4400 Lumens per lamp. Efficiency: 81.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.760 23.760
15 1323 1360 1366 382
prismatic lens. Ballast: B254UNV-E Report is based on 4400 Lumens per lamp. Efficiency: 84.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800
15 2228 2326 2406 658
25 1235 1232 1213 566
25 2079 2280 2417 1044
35 1101 1028 1017 651
35 1851 2134 2220 1303
45 889 796 818 631
45 1548 1790 1827 1348
55 598 566 642 529
55 1173 1345 1428 1197
65 319 390 545 410
65 771 963 1099 950
75 121 241 317 239
75 383 625 665 597
85 10 10 10 24
85 75 95 60 125
90 2 2 2
90
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 1081 24.6 30.3 00-040 1732 39.4 48.6 00-060 2892 65.7 81.1 00-090 3566 81.0 100.0 90-180 0000 0.0 000.0 00-180 3566 81.0 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 1926 21.9 25.9 00-040 3229 36.7 43.4 00-060 5774 65.6 77.5 00-090 7446 84.6 100.0 90-180 0000 00.0 000.0 00-180 7446 84.6 100.0
01 89 85 82 80 77 75 77 75 73 02 81 74 69 70 66 62 67 64 61 03 74 66 59 62 57 53 60 55 52 04 68 58 51 55 50 45 53 49 45 05 63 52 45 50 44 39 48 43 39 06 58 47 40 45 39 35 44 38 34 07 54 43 36 41 35 31 40 35 31 08 50 39 33 38 32 28 37 31 27 09 47 36 30 35 29 25 34 29 25 10 44 33 27 32 27 23 31 26 23
01 92 88 84 82 79 77 79 77 74 02 83 76 70 71 67 63 69 65 61 03 76 67 59 63 57 52 60 56 51 04 69 59 51 56 49 44 54 48 44 05 64 52 45 50 43 38 48 42 38 06 59 47 39 45 38 33 43 37 33 07 54 43 35 41 34 29 39 34 29 08 50 39 32 37 31 26 36 30 26 09 47 36 29 34 28 24 33 27 23 10 44 33 26 31 25 21 31 25 21
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1717. 1537. 1580. 55 1424. 1347. 1528. 65 1031. 1260. 1761. 75 638. 1271. 1672. 85 157. 157. 157.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3179. 3676. 3752. 55 2970. 3405. 3615. 65 2649. 3309. 3776. 75 2149. 3507. 3731. 85 1250. 1583. 1000.
S
G
R
Body Style:
Ceiling Type:
Reflector:
Lamp Quantity 1=1 Lamp 2=2 Lamp
Fits both Standard Grid
Ballast Type:
HY For NYC Code – I.B.E.W. Manufactured
HN For NYC Code – Local 3 Manufactured
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.
Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Specifications Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 3776 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.1%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.