Page 1 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens




Exposed T-bar by others
Exposed T-bar by others
1-1/2" max.
1-7/8" max.
Acoustical material by others
Acoustical material by others

exposed slot t-grid ceiling


2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.
fully enclosed lamp compartment
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens
Model No. H9S2GLR214120PG LER = FP - 58.9 IW - 31.9 BF - 1.0 Comparative yearly lighting energy cost per
Model No. HP9S2GLR224120PG LER = FP - 66.5 IW - 47.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $4.07
1000 lumens = $3.61


0 602 602 602
0 955 955 955
5 599 604 609 58
5 953 958 966 92
prismatic lens. Ballast: B228PUNV-C Report is based on 1220 Lumens per lamp. Efficiency: 77.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800
15 577 613 642 173
prismatic lens. Ballast: B224PUNV-C Report is based on 2000 Lumens per lamp. Efficiency: 76.5% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800
15 934 976 1019 277
25 535 612 633 275
25 886 980 1008 443
35 474 548 562 336
35 786 878 895 539
45 393 448 456 339
45 648 720 728 546
55 292 329 355 295
55 485 534 569 479
65 184 231 277 231
65 324 381 446 382
75 89 145 178 145
75 177 244 291 248
85 17 23 19 29
85 34 43 35 53
90 2 2 2
90 3 3 3
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL LUMEN SUMMARY
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 506 20.7 26.9 00-040 842 34.5 44.7 00-060 1476 60.5 78.5 00-090 1881 77.1 100.0 90-180 0000 0.0 000.0 00-180 1881 77.1 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
ZONE LUMENS % LAMP % FIXT 00-030 811 20.3 26.5 00-040 1350 33.8 44.1 00-060 2376 59.4 77.7 00-090 3060 76.5 100.0 90-180 0000 00.0 000.0 00-180 3060 76.5 100.0
01 84 80 77 75 73 70 72 70 68 02 76 70 64 65 61 58 63 59 56 03 69 61 55 58 52 48 55 51 47 04 63 54 47 51 46 41 49 44 41 05 58 48 41 46 40 35 44 39 35 06 54 43 36 41 35 31 40 35 31 07 50 39 33 37 32 27 36 31 27 08 46 36 29 34 29 24 33 28 24 09 43 33 26 32 26 22 31 26 22 10 41 30 24 29 24 20 28 23 20
01 83 79 76 74 72 69 71 69 67 02 75 69 64 65 61 57 62 59 56 03 69 60 54 57 52 48 55 50 47 04 63 53 46 50 45 40 49 44 40 05 58 48 41 45 39 35 44 38 34 06 53 43 36 41 35 30 39 34 30 07 49 39 32 37 31 27 36 31 27 08 46 35 29 34 28 24 33 28 24 09 43 32 26 31 25 22 30 25 21 10 40 30 24 29 23 20 28 23 19
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1657. 1888. 1922. 55 1517. 1710. 1845. 65 1298. 1629. 1954. 75 1025. 1670. 2050. 85 581. 787. 650.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2731. 3035. 3069. 55 2520. 2775. 2957. 65 2285. 2687. 3146. 75 2038. 2810. 3351. 85 1163. 1471. 1197.
S
G
R
Body Style:
Ceiling Type:
Reflector:
Lamp Quantity 2=2 Lamp
Fits both Standard Grid
Ballast Type:
HY For NYC Code – I.B.E.W. Manufactured
HN For NYC Code – Local 3 Manufactured
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.
Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor. See Folio OA20-10..
Specifications Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80. To reduce glare the average brightness at 65° shall not exceed 1954 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.1%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum .95% reflectance.