HP90 Recessed Fluorescent H9S2GLR214 or 224

Page 1 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens

Static, 2 Lamp T5

  • Features
  • 77.1% efficient (2 lamp, 14W).
  • 76.5% efficient (2 lamp, 24W).
  • Direct/indirect appearance with soft contoured interior.
  • Lens encloses lamp compartment.
  • Translucent DR acrylic linear prismatic lens.
  • Tension screws secure ends to body.
  • Same fixture fits both G and T ceiling types.
  • Fits flush to face of slot grid (T) ceiling types.
  • Lamp shield opens from either side.
  • 95% reflective specular aluminum reflector.
  • Ballast accessible from room side.
  • Built-in earthquake clips.
  • Can be continuous row mounted.
  • Wiring access plate standard.
  • Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
  • Construction to meet NYC Code or Chicago Plenum available.
Lightolier H9S2GLR224 — Static, 2 Lamp T5 diagram (page 1)
図 1 · Static, 2 Lamp T5

Mounting Methods Dimensions

Lightolier H9S2GLR224 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier H9S2GLR224 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions
Lightolier H9S2GLR224 — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

Exposed T-bar by others

Exposed T-bar by others

1-1/2" max.

1-7/8" max.

Acoustical material by others

Acoustical material by others

Lightolier H9S2GLR224 — Mounting Methods Dimensions diagram (page 1)
図 5 · Mounting Methods Dimensions

exposed slot t-grid ceiling

Lightolier H9S2GLR224 — Mounting Methods Dimensions diagram (page 1)
図 6 · Mounting Methods Dimensions
Lightolier H9S2GLR224 — Mounting Methods Dimensions diagram (page 1)
図 7 · Mounting Methods Dimensions

2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.

fully enclosed lamp compartment

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-15
Show 12 more labels / short text on this page
5" (127mm) · 5" (127mm) · 24" (610mm) · 15/16" · 9/16" · 24" · 24" · exposed t-grid ceiling · 2-1/2" (64mm) · built-in earthquake clips · 24" (610mm) · 11/06
Page 2 of the Lightolier H9S2GLR224 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

HP90 Recessed Fluorescent H9S2GLR214 or 224

Page 2 of 2 Direct/Indirect – 2' x 2' with Acrylic Linear Prismatic Lens

Static, 2 Lamp T5

Model No. H9S2GLR214120PG LER = FP - 58.9 IW - 31.9 BF - 1.0 Comparative yearly lighting energy cost per

Model No. HP9S2GLR224120PG LER = FP - 66.5 IW - 47.0 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $4.07

CANDELA DISTRIBUTION 0

1000 lumens = $3.61

CANDELA DISTRIBUTION 0

Lightolier H9S2GLR224 — CANDELA DISTRIBUTION 0 diagram (page 2)
図 8

0.0 45.0 90.0 FLUX

Lightolier H9S2GLR224 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 9
Report NumberG2006122 Catalog Number: H9S2GLR214120PG Lamps: F14T5 Luminaire: HP90 2' x 2' with linear
Report NumberG2006116 Catalog Number: HP9S2GLR224120PG Lamps: F24T5 HO Luminaire: HP90 2' x 2' with linear

0.0 45.0 90.0 FLUX

0 602 602 602

0 955 955 955

5 599 604 609 58

5 953 958 966 92

prismatic lens. Ballast: B228PUNV-C Report is based on 1220 Lumens per lamp. Efficiency: 77.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800

15 577 613 642 173

prismatic lens. Ballast: B224PUNV-C Report is based on 2000 Lumens per lamp. Efficiency: 76.5% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.800 22.800

15 934 976 1019 277

25 535 612 633 275

25 886 980 1008 443

35 474 548 562 336

35 786 878 895 539

45 393 448 456 339

45 648 720 728 546

55 292 329 355 295

55 485 534 569 479

65 184 231 277 231

65 324 381 446 382

75 89 145 178 145

75 177 244 291 248

85 17 23 19 29

85 34 43 35 53

90 2 2 2

90 3 3 3

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 00-030 506 20.7 26.9 00-040 842 34.5 44.7 00-060 1476 60.5 78.5 00-090 1881 77.1 100.0 90-180 0000 0.0 000.0 00-180 1881 77.1 100.0

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 00-030 811 20.3 26.5 00-040 1350 33.8 44.1 00-060 2376 59.4 77.7 00-090 3060 76.5 100.0 90-180 0000 00.0 000.0 00-180 3060 76.5 100.0

01 84 80 77 75 73 70 72 70 68 02 76 70 64 65 61 58 63 59 56 03 69 61 55 58 52 48 55 51 47 04 63 54 47 51 46 41 49 44 41 05 58 48 41 46 40 35 44 39 35 06 54 43 36 41 35 31 40 35 31 07 50 39 33 37 32 27 36 31 27 08 46 36 29 34 29 24 33 28 24 09 43 33 26 32 26 22 31 26 22 10 41 30 24 29 24 20 28 23 20

01 83 79 76 74 72 69 71 69 67 02 75 69 64 65 61 57 62 59 56 03 69 60 54 57 52 48 55 50 47 04 63 53 46 50 45 40 49 44 40 05 58 48 41 45 39 35 44 38 34 06 53 43 36 41 35 30 39 34 30 07 49 39 32 37 31 27 36 31 27 08 46 35 29 34 28 24 33 28 24 09 43 32 26 31 25 22 30 25 21 10 40 30 24 29 23 20 28 23 19

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1657. 1888. 1922. 55 1517. 1710. 1845. 65 1298. 1629. 1954. 75 1025. 1670. 2050. 85 581. 787. 650.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2731. 3035. 3069. 55 2520. 2775. 2957. 65 2285. 2687. 3146. 75 2038. 2810. 3351. 85 1163. 1471. 1197.

Ordering Information Explanation of Catalog Number. Example: H9S2GLR224120PGGLR

S

G

R

Body Style:

Ceiling Type:

Acrylic Lens Lamp(By Others) 14 =T5 14W 24 =T5HO 24W (Nominal 24")

Reflector:

Lamp Quantity 2=2 Lamp

Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog

Fits both Standard Grid

no., ie(GLR)

Ballast Type:

H9 Standard HP90

HY For NYC Code – I.B.E.W. Manufactured

HN For NYC Code – Local 3 Manufactured

Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.

Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Consult factory. For motion or light sensor. See Folio OA20-10..

Specifications Performance: In an installation of 2 lamp 14W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80. To reduce glare the average brightness at 65° shall not exceed 1954 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.1%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum .95% reflectance.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-15
Show 7 more labels / short text on this page
HP90 Direct/Indirect · Fixture · S = Static · Width · Specular Aluminum · Recessed · and Slot Grid
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier H9S2GLR224について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier H9S2GLR224に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier H9S2GLR224 取扱説明書(PDF)

2 ページ·253 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…