JA
Lightolier logo
公式取扱説明書

Lightolier H9S2GLR228

2 ページ·237 KB·インテリア家具・調度品·PDF·EN
Lightolier H9S2GLR228
目次 14セクション HP90 Recessed Fluorescent H9S2GLR228 or 128 · Static, 1 or 2 Lamp T5 · Mounting Methods Dimensions · Job Information Type: · … 表示非表示
Page 1 of the Lightolier H9S2GLR228 user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

HP90 Recessed Fluorescent H9S2GLR228 or 128

Page 1 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens

Static, 1 or 2 Lamp T5

  • Features
  • Can provide 54.6 maintained footcandles of balanced brightness illumination at only .68 watts per square foot.
  • 87.2% efficient (1 lamp, 28W).
  • 90.4% efficient (2 lamp, 28W).
  • Direct/indirect appearance with soft contoured interior.
  • Lens encloses lamp compartment.
  • Translucent DR acrylic linear prismatic lens.
  • Tension screws secure ends to body.
  • Same fixture fits both G and T ceiling types.
  • Fits flush to face of slot grid (T) ceiling types.
  • Lamp shield opens from either side.
  • 95% reflective specular aluminum reflector.
  • Ballast accessible from room side.
  • Can be continuous row mounted.
  • Wiring access plate standard.
  • Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming commands from computers, scene controllers and automatic control devices.
  • Construction to meet NYC Code or Chicago Plenum available.
Lightolier H9S2GLR228 — Static, 1 or 2 Lamp T5 diagram (page 1)
図 1 · Static, 1 or 2 Lamp T5

Mounting Methods Dimensions

Lightolier H9S2GLR228 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier H9S2GLR228 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions
Lightolier H9S2GLR228 — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

Exposed T-bar by others

Exposed T-bar by others

1-1/2" max.

1-7/8" max.

Acoustical material by others

Acoustical material by others

Lightolier H9S2GLR228 — Mounting Methods Dimensions diagram (page 1)
図 5 · Mounting Methods Dimensions

exposed slot t-grid ceiling

Lightolier H9S2GLR228 — Mounting Methods Dimensions diagram (page 1)
図 6 · Mounting Methods Dimensions
Lightolier H9S2GLR228 — Mounting Methods Dimensions diagram (page 1)
図 7 · Mounting Methods Dimensions
Lightolier H9S2GLR228 — Mounting Methods Dimensions diagram (page 1)
図 8 · Mounting Methods Dimensions

2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.

fully enclosed lamp compartment

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-10
Show 15 more labels / short text on this page
5" (127mm) · 5" (127mm) · 24" (610mm) · 15/16" · 9/16" · 5" (127mm) · 24" · 24" · exposed t-grid ceiling · 5" (127mm) · 24" (610mm) · 2-1/2" (64mm) · built-in earthquake clips · 48" (1219mm) · 11/06
Page 2 of the Lightolier H9S2GLR228 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

HP90 Recessed Fluorescent H9S2GLR228 or 128

Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens

Static, 1 or 2 Lamp T5

Model No. H9S2GLR128UNVPG LER = FP - 75.8 IW - 31.55 BF - 1.0 Comparative yearly lighting energy cost per

Model No. H9S2GLR228120WA LER = FP - 84.3 IW - 54.6 BF - 0.93 Comparative yearly lighting energy cost per

CANDELA DISTRIBUTION 0

CANDELA DISTRIBUTION 0

1000 lumens = $3.16

1000 lumens = $2.85

Lightolier H9S2GLR228 — CANDELA DISTRIBUTION 0 diagram (page 2)
図 9

0.0 45.0 90.0 FLUX

Lightolier H9S2GLR228 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 10

0.0 45.0 90.0 FLUX

Report NumberG2006156 Catalog Number: H9S2GLR128UNVPG Lamps: F28 T5 Luminaire: HP90 2' x 4' with linear
Report NumberG2006010 Catalog Number: H9S2GLR228120WA Lamps: F28T5 Luminaire: HP90 2' x 4' with linear

0 877 877 877

0 1632 1632 1632

5 868 876 884 84

5 1621 1634 1645 156

15 1561 1598 1621 451

prismatic lens. Ballast: QTP 2X28 T5/UNV-PSN Report is based on 2750 Lumens per lamp. Efficiency: 87.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.760 23.760

15 843 860 868 242

prismatic lens. Ballast: WA Report is based on 2750 Lumens per lamp. Efficiency: 90.4% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800

25 1448 1511 1568 697

25 792 794 785 364

35 713 672 658 424

35 1278 1386 1442 857

45 592 528 536 418

45 1048 1169 1202 886

55 420 386 424 359

55 778 891 941 789

65 506 642 749 635

65 239 266 352 280

75 250 427 478 412

75 102 183 254 188

85 20 31 28 38

85 51 72 60 88

90 2 2 2

90 5 5 5

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 00-030 690 25.1 28.8 00-040 1115 40.5 46.5 00-060 1892 68.8 78.9 00-090 2398 87.2 100.0 90-180 0000 00.0 000.0 00-180 2398 87.2 100.0

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 00-030 1305 23.7 26.2 00-040 2162 39.3 43.5 00-060 3837 69.8 77.2 00-090 4972 90.4 100.0 90-180 0000 0.0 000.0 00-180 4972 90.4 100.0

01 95 91 87 85 82 80 82 79 77 02 86 79 73 74 70 66 71 68 64 03 79 70 62 66 60 55 63 58 54 04 72 62 54 58 52 47 56 51 47 05 66 55 47 52 46 41 51 45 41 06 61 50 42 47 41 36 46 40 36 07 57 45 38 43 37 32 42 36 32 08 53 41 34 40 33 29 39 33 28 09 50 38 31 36 30 26 36 30 26 10 47 35 28 34 28 24 33 27 23

01 98 94 90 88 85 82 84 82 79 02 89 81 75 76 71 67 73 69 66 03 81 71 63 67 61 56 64 59 55 04 74 63 55 59 53 47 57 51 47 05 68 56 48 53 46 41 51 45 40 06 63 50 42 48 41 36 46 40 35 07 58 46 38 43 37 32 42 36 31 08 54 42 34 40 33 28 39 32 28 09 50 38 31 37 30 25 36 30 25 10 47 35 28 34 27 23 33 27 23

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1143. 1020. 1035. 55 1000. 919. 1009. 65 772. 859. 1137. 75 538. 965. 1340. 85 313. 486. 439.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2152. 2401. 2468. 55 1970. 2256. 2382. 65 1739. 2206. 2574. 75 1403. 2396. 2682. 85 850. 1200. 1000.

Ordering Information Explanation of Catalog Number. Example: H9S2GLR128120WAGLR

S

G

R

Body Style:

Ceiling Type:

Reflector:

Lamp Quantity 1=1 Lamp 2=2 Lamp Ballast Type:

Lamp(By Others) 28 =T5 288W (Nominal 48")
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog

Fits both Standard Grid

no., ie(GLR)

H9 Standard HP90

HY For NYC Code – I.B.E.W. Manufactured

HN For NYC Code – Local 3 Manufactured

Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor. See Folio OA20-10.

Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Specifications Performance: In an installation of 2 lamp 28W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .94. To reduce glare the average brightness at 65° shall not exceed 2574 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 73.8%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-10
Show 8 more labels / short text on this page
HP90 Direct/Indirect · Fixture · Acrylic Lens · S = Static · Width · Specular Aluminum · Recessed · and Slot Grid
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier H9S2GLR228について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier H9S2GLR228に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier H9S2GLR228 取扱説明書(PDF)

2 ページ·237 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…