Page 1 of 2 Direct/Indirect Semi-Recessed Fluorescent 2' x 2' with Acrylic Linear Prismatic Lens, 2 Lamp T5




Exposed T-bar by others
1-1/2" max.
Exposed T-bar by others
Acoustical material by others
1-7/8" max.
Acoustical material by others
* For flush mounting when using 9/16" Exposed T-Grid ceiling system consult factory
exposed slot t-grid ceiling

Lens opens from either side
24" (610mm)
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:

Page 2 of 2 Direct/Indirect Semi-Recessed Fluorescent 2' x 2' with Acrylic Linear Prismatic Lens, 2 Lamp T5
Model No. HDS2GLW214120PG LER = FP - 58.1 IW - 30.6 BF - 1.O Comparative yearly lighting energy cost per
Model No. HDS2GLW224120PG LER = FP - 66.0 IW - 46.7 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $4.13
1000 lumens = $3.63


0 511 511 511
0 885 885 885
5 508 509 512 49
5 882 882 885 84
with linear prismatic lens. Ballast: ER21120MHT Report is based on 1200 Lumens per lamp. Efficiency: 74.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
15 486 495 502 140
with linear prismatic lens. Ballast: ER224120MHT Report is based on 2000 Lumens per lamp. Efficiency: 77.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 23.040 23.040
15 844 858 870 243
25 446 466 484 215
25 774 808 839 373
35 389 425 458 266
35 674 735 795 460
45 315 370 420 285
45 546 643 731 495
55 227 310 376 274
55 391 537 655 474
65 131 248 324 237
65 227 430 561 409
75 59 188 264 185
75 102 323 461 320
85 13 131 212 130
85 22 225 368 226
90 2 84 151
90 3 146 265
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONE LUMENS % LAMP % FIXT 00-030 403 16.8 22.7 00-040 669 27.9 37.6 00-060 1228 51.2 69.0 00-090 1780 74.1 100.0 90-180 0000 0.0 000.0 00-180 1780 74.1 100.0
ZONE LUMENS % LAMP % FIXT 00-030 699 17.5 22.7 00-040 1160 29.0 37.6 00-060 2129 53.2 69.0 00-090 3083 77.1 100.0 90-180 0000 00.0 000.0 00-180 3083 77.1 100.0
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
01 79 74 70 69 66 63 66 64 61 02 71 64 58 59 55 51 57 53 50 03 64 55 48 52 46 42 50 45 41 04 58 49 41 46 40 35 44 39 35 05 54 43 36 41 35 30 39 34 30 06 49 39 32 37 31 26 35 30 26 07 47 35 28 33 27 23 32 27 23 08 43 32 25 30 25 20 29 24 20 09 40 29 23 28 22 18 27 22 18 10 37 27 21 26 20 17 25 20 17
01 82 77 73 72 69 66 69 66 64 02 73 66 60 62 57 53 59 55 51 03 67 57 50 54 48 43 51 47 43 04 61 50 43 47 41 36 46 40 36 05 56 45 37 42 36 31 41 35 31 06 51 40 33 38 32 27 37 31 27 07 47 36 29 35 28 24 33 28 24 08 44 33 26 32 26 21 31 25 21 09 41 30 24 29 23 19 28 23 19 10 39 28 22 27 21 17 26 21 17
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1183. 1390. 1578. 55 1012. 1382. 1676. 65 746. 1413. 1846. 75 486. 1548. 2174. 85 204. 2059. 3332.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 2051. 2415. 2746. 55 1743. 2394. 2920. 65 1293. 2450. 3196. 75 840. 2660. 3797. 85 346. 3536. 5783.
HD
S
G
W
Body Style:
Ceiling Type:
Reflector:
Lamp Quantity 2=2 Lamp
Fits both Standard Grid
Ballast Type:
Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: A.
Specifications (continued) Cavity – Soft white post painted polyester powder. Rust preventative undercoating. Reflector – Soft white post painted polyester powder. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow blow fusing: SUFFIX: C. Drywall Kit: Order Catalog Number: FK92X2. Electrical Wiring Options: Emergency Packs are only avalable for remote mounting. Consult factory. For motion or light sensor. See Folio OA20-10.
Specifications Performance: In an installation of 2 lamp 24W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To reduce glare the average brightness at 65° shall not exceed 3196 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 77.3%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – Soft white post painted polyester powder.