目次 14セクション HP90 Recessed Fluorescent H9S2GLR254 or 154 · Static, 1 or 2 Lamp T5 · Mounting Methods Dimensions · Job Information Type: · … 表示非表示
Page 1 of the Lightolier HP90 user manual — Job Information Type:
1ページ · クリックして拡大
1ページ

HP90 Recessed Fluorescent H9S2GLR254 or 154

Page 1 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens

Static, 1 or 2 Lamp T5

  • Features
  • 84.6% efficient (2 lamp, 54W).
  • 81.0% efficient (1 lamp, 54W).
  • Direct/indirect appearance with soft contoured interior.
  • Lens encloses lamp compartment.
  • Translucent DR acrylic linear prismatic lens.
  • Tension screws secure ends to body.
  • Same fixture fits both G and T ceiling types.
  • Fits flush to face of slot grid (T) ceiling types.
  • Lamp shield opens from either side.
  • 95% reflective specular aluminum reflector.
  • Ballast accessible from room side.
  • Built-in earthquake clips.
  • Can be continuous row mounted.
  • Wiring access plate standard.
  • Optional DALI ballast i GEN TECHNOLOGY accepts digital dimming controllers, scene controllers and automatic control devices.
  • Construction to meet NYC Code or Chicago Plenum available.
Lightolier HP90 — Static, 1 or 2 Lamp T5 diagram (page 1)
図 1 · Static, 1 or 2 Lamp T5

Mounting Methods Dimensions

Lightolier HP90 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier HP90 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions
Lightolier HP90 — Mounting Methods Dimensions diagram (page 1)
図 4 · Mounting Methods Dimensions

Exposed T-bar by others

Exposed T-bar by others

1-1/2" max.

1-7/8" max.

Acoustical material by others

Acoustical material by others

Lightolier HP90 — Mounting Methods Dimensions diagram (page 1)
図 5 · Mounting Methods Dimensions

exposed slot t-grid ceiling

Lightolier HP90 — Mounting Methods Dimensions diagram (page 1)
図 6 · Mounting Methods Dimensions
Lightolier HP90 — Mounting Methods Dimensions diagram (page 1)
図 7 · Mounting Methods Dimensions
Lightolier HP90 — Mounting Methods Dimensions diagram (page 1)
図 8 · Mounting Methods Dimensions

2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.

fully enclosed lamp compartment

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-11
Show 15 more labels / short text on this page
5" (127mm) · 5" (127mm) · 24" (610mm) · 15/16" · 9/16" · 5" (127mm) · 24" · 24" · exposed t-grid ceiling · 5" (127mm) · 24" (610mm) · 2-1/2" (64mm) · built-in earthquake clips · 48" (1219mm) · 11/06
Page 2 of the Lightolier HP90 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

HP90 Recessed Fluorescent H9S2GLR254 or 154

Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens

Static, 1 or 2 Lamp T5

Model No. H9S2GLR154UNVPG LER = FP - 57.1 IW - 62.4 BF - 1.0 Comparative yearly lighting energy cost per

Model No. H9S2GLR254UNVPG LER = FP - 66.5 IW - 112.39 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $4.20

CANDELA DISTRIBUTION 0

1000 lumens = $3.61

CANDELA DISTRIBUTION 0

Lightolier HP90 — CANDELA DISTRIBUTION 0 diagram (page 2)
図 9

0.0 45.0 90.0 FLUX

Lightolier HP90 — 0.0 45.0 90.0 FLUX diagram (page 2)
図 10

Report Number: G2006154 Catalog Number: H9S2GLR154UNVPG Lamps: F54 T5 HO Luminaire: HP90 2' x 4' with linear

Report Number: G2006118 Catalog Number: H9S2GLR254UNVPG Lamps: F54 T5 HO Luminaire: HP90 2' x 4' with linear

0.0 45.0 90.0 FLUX

0 1393 1393 1393

0 2340 2340 2340

5 1374 1395 1411 133

5 2320 2339 2354 223

prismatic lens. Ballast: Advance ICN-2S54 UNV PG Report is based on 4400 Lumens per lamp. Efficiency: 81.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.2 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.760 23.760

15 1323 1360 1366 382

prismatic lens. Ballast: B254UNV-E Report is based on 4400 Lumens per lamp. Efficiency: 84.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 22.800

15 2228 2326 2406 658

25 1235 1232 1213 566

25 2079 2280 2417 1044

35 1101 1028 1017 651

35 1851 2134 2220 1303

45 889 796 818 631

45 1548 1790 1827 1348

55 598 566 642 529

55 1173 1345 1428 1197

65 319 390 545 410

65 771 963 1099 950

75 121 241 317 239

75 383 625 665 597

85 10 10 10 24

85 75 95 60 125

90 2 2 2

90

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL LUMEN SUMMARY

ZONAL LUMEN SUMMARY

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 00-030 1081 24.6 30.3 00-040 1732 39.4 48.6 00-060 2892 65.7 81.1 00-090 3566 81.0 100.0 90-180 0000 0.0 000.0 00-180 3566 81.0 100.0

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

ZONE LUMENS % LAMP % FIXT 00-030 1926 21.9 25.9 00-040 3229 36.7 43.4 00-060 5774 65.6 77.5 00-090 7446 84.6 100.0 90-180 0000 00.0 000.0 00-180 7446 84.6 100.0

01 89 85 82 80 77 75 77 75 73 02 81 74 69 70 66 62 67 64 61 03 74 66 59 62 57 53 60 55 52 04 68 58 51 55 50 45 53 49 45 05 63 52 45 50 44 39 48 43 39 06 58 47 40 45 39 35 44 38 34 07 54 43 36 41 35 31 40 35 31 08 50 39 33 38 32 28 37 31 27 09 47 36 30 35 29 25 34 29 25 10 44 33 27 32 27 23 31 26 23

01 92 88 84 82 79 77 79 77 74 02 83 76 70 71 67 63 69 65 61 03 76 67 59 63 57 52 60 56 51 04 69 59 51 56 49 44 54 48 44 05 64 52 45 50 43 38 48 42 38 06 59 47 39 45 38 33 43 37 33 07 54 43 35 41 34 29 39 34 29 08 50 39 32 37 31 26 36 30 26 09 47 36 29 34 28 24 33 27 23 10 44 33 26 31 25 21 31 25 21

LUMINANCE DATA IN CANDELA/SQ. METER

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 1717. 1537. 1580. 55 1424. 1347. 1528. 65 1031. 1260. 1761. 75 638. 1271. 1672. 85 157. 157. 157.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3179. 3676. 3752. 55 2970. 3405. 3615. 65 2649. 3309. 3776. 75 2149. 3507. 3731. 85 1250. 1583. 1000.

Ordering Information Explanation of Catalog Number. Example: H9S2GLR254UNVPGGLR

S

G

R

Body Style:

Ceiling Type:

Reflector:

Lamp Quantity 1=1 Lamp 2=2 Lamp

Lamp(By Others) 54 =T5 54W (Nominal 48")
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog

Fits both Standard Grid

no., ie(GLR)

Ballast Type:

H9 Standard HP90

HY For NYC Code – I.B.E.W. Manufactured

HN For NYC Code – Local 3 Manufactured

Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.

Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X4. Electrical Wiring Options: Consult factory. For motion or light sensor: See Folio OA20-10.

Specifications (continued) Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Specifications Performance: In an installation of 2 lamp 54W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 3776 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.1%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: Linear prismatic translucent DR acrylic lens. Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat white acrylic enamel. Phosphate undercoating. Reflector – low iridescence specular aluminum 95% reflectance.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2006 a Genlyte company Section 5/Folio M32-11
Show 8 more labels / short text on this page
HP90 Direct/Indirect · Fixture · Acrylic Lens · S = Static · Width · Specular Aluminum · Recessed · and Slot Grid
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier HP90について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier HP90に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier HP90 取扱説明書(PDF)

2 ページ·236 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…