Lytecel Recessed Fluorescent LCS6G20LW228

Page 1 of 2 For Continuous Row Mounting, 6" wide x 48", 20 Cell (1 Row) Parabolic Louver,

Air Return/Static, 2 Lamp T5, IES RP1 For VDT Areas

  • Features
  • 48" long louver gives an uninterrupted louver appearance when row mounted. Ideal for continuous row applications.
  • 52.0% efficient (2 lamp) semi-specular louver.
  • 55.3% efficient (2 lamp) specular louver.
  • 1.3 spacing mounting ratio semi-specular louver
  • 1.5 spacing mounting ratio specular louver.
  • Semi-specular or specular, low iridescence, pre-anodized aluminum louver.
  • Vertical grain on cross blades eliminates reflected lamp image.
  • Spring loaded latches (self centering).
  • Louver has protective dust guard.
  • Only 5-1/2" deep body.
  • Black housing exterior for cooler ballast operating temperature.
  • UL-Listed twin knockout access plate.
  • Meets NYC Code requirements.
  • Construction to meet Chicago Plenum Code is available.
  • Optional DALI ballast accepts digital dimming commands from computers, scene controllers and automatic control devices.
Lightolier LCS6G20LW228 — Air Return/Static, 2 Lamp T5, IES RP1 For VDT Areas diagram (page 1)
図 1 · Air Return/Static, 2 Lamp T5, IES RP1 For VDT Areas

Mounting Methods Dimensions

Lightolier LCS6G20LW228 — Mounting Methods Dimensions diagram (page 1)
図 2 · Mounting Methods Dimensions
Lightolier LCS6G20LW228 — Mounting Methods Dimensions diagram (page 1)
図 3 · Mounting Methods Dimensions

G

exposed T-grid ceiling.

T

exposed slot T-grid ceiling.

Lightolier LCS6G20LW228 — T diagram (page 1)
図 4
Lightolier LCS6G20LW228 — T diagram (page 1)
図 5

2" max.

2" max.

End Trim required for beginning and end of row. Order Catalog Number: LC6 END TRIM

Joint of Two Units

Fixture Continuous Screw Row Coupler Side Rail Hold-down Hold-down Clip coupler/clamp (LC85 CLAMP) (Order for end of row)Clip Fixture Fixture Continuous Screw Row Coupler Side Hold-down Rail Clip continuous row coupler locks fixtures together for a continuous line of light without cell configuration interruption (supplied with fixture)
Lightolier LCS6G20LW228 — Joint of Two Units diagram (page 1)
図 6 · Joint of Two Units

2" x 2-1/2" Access Plate with (2) 7/8" K.O.s

Lightolier LCS6G20LW228 — Joint of Two Units diagram (page 1)
図 7 · Joint of Two Units

Air Return Slots (LCA only)

48" (1220mm) 39-1/4" (997mm)

Lightolier LCS6G20LW228 — Joint of Two Units diagram (page 1)
図 8 · Joint of Two Units

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 2/Folio G07-46 3/07
Show 14 more labels / short text on this page
Hold-down Clip · Hold-down Clip · 5-1/2" (139mm) · LC6 End Trim · 15/16" or 9/16" · 48" (1220mm) · 48" (1220mm) · 9/16" · 4-1/4" (108mm) · 6" · 6" · 6" (162mm) · 7-3/8" (187mm) · 1-3/4" (44mm)
Page 2 of the Lightolier LCS6G20LW228 user manual — Job Information Type:
2ページ · クリックして拡大
2ページ

Lytecel Recessed Fluorescent LCS6G20LW228

Page 2 of 2 For Continuous Row Mounting, 6" wide x 48", 20 Cell (1 Row) Parabolic Louver,

Air Return/Static, 2 Lamp T5, IES RP1 For VDT Areas

Model No. LCS6G20LW228120PG LER = FP - 43.3 IW - 66.0 BF - 1.0 Comparative yearly lighting energy cost per

Model No. LCS6G20PW228120PG LER = FP - 45.8 IW - 66.0 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $5.54 Report Number: G1206007 Catalog Number: LCS6G20LW228120PG Lamp: F28 T5 Luminaire: 6" wide Troffer with semi- specular louver. Ballast: Advance ICN-2S28 Report is based on 2750 Lumens per lamp. Efficiency: 52.0% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.943 5.816

CANDELA DISTRIBUTION

1000 lumens = $5.24 Report Number: G1206008 Catalog Number: LCS6G20PW228120PG Lamps: F28 T5 Luminaire: 6" wide Troffer with specular louver. Ballast: Advance ICN-2S28 Report is based on 2750 Lumens per lamp. Efficiency: 55.3% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.3 1.5 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.943 5.816

CANDELA DISTRIBUTION

Lightolier LCS6G20LW228 — CANDELA DISTRIBUTION diagram (page 2)
図 9
Lightolier LCS6G20LW228 — CANDELA DISTRIBUTION diagram (page 2)
図 10

0.0 45.0 90.0 FLUX

0.0 45.0 90.0 FLUX

0 1373 1373 1373

0 1348 1347 1348

5 1300 1383 1363 133

5 1337 1348 1377 134

15 1278 1420 1516 393

15 1278 1470 1522 414

25 1188 1382 1403 614

25 1184 1483 1448 649

35 1023 1139 1216 711

35 1079 1221 1262 756

45 829 868 861 668

45 893 963 980 737

55 488 348 137 288

55 586 377 113 314

65 26 36 31 37

65 1 35 29 27

75 3 5 9 6

75 1 4 9 5

85 1 2 3 2

85 1 2 4 2

90 1 2 1

90 0 1 1

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

TYPICAL V.C.P.'s

TYPICAL V.C.P.'s

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

Mounting Height Lengthwise Crosswise Room Luminaires Luminaires Size 0 Deg Plane 90 Deg Plane 8.5 10 8.5 10 8.5 10 8.5 10 30x30 87 84 80 71 93 89 85 76 40x40 87 84 81 78 94 91 89 80 60x30 87 84 81 77 93 89 87 78 60x60 87 83 81 79 94 91 90 83 100x100 88 83 81 79 94 92 91 86

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

Mounting Height Lengthwise Crosswise Room Luminaires Luminaires Size 0 Deg Plane 90 Deg Plane 8.5 10 8.5 10 8.5 10 8.5 10 30x30 86 76 73 71 93 88 85 70 40x40 86 76 75 74 94 90 87 79 60x30 86 76 75 76 93 88 85 77 60x60 86 77 76 76 94 91 89 82 100x100 86 77 76 76 93 92 91 85

1 58 56 55 53 52 51 51 50 49 2 54 51 48 48 46 45 47 45 44 3 50 46 43 44 41 39 43 41 39 4 47 42 38 40 37 35 39 36 34 5 44 38 34 37 33 31 36 33 31 6 41 35 31 33 30 28 33 30 27 7 38 32 28 31 27 25 30 27 25 8 35 29 25 28 25 23 28 25 22 9 33 27 23 26 23 20 26 23 20 10 31 25 21 24 21 19 24 21 19

1 62 60 58 56 55 54 54 53 52 2 58 54 51 51 49 47 50 48 46 3 54 49 46 47 44 42 45 43 41 4 50 45 41 43 39 37 41 39 36 5 46 40 36 39 35 33 38 35 32 6 43 37 33 35 32 29 35 31 29 7 40 34 30 33 29 26 32 29 26 8 38 31 27 30 26 24 29 26 24 9 35 29 24 28 24 22 27 24 21 10 33 26 22 26 22 20 25 22 20

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

AVERAGE AVERAGE AVERAGE AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 1144 20.8 40.0 00-040 1856 33.7 64.9 00-060 2812 51.1 98.4 00-090 2858 52.0 100.0 90-180 0000 0.0 000.0 00-180 2858 52.0 100.0

AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 1198 21.8 39.4 00-040 1954 35.5 64.3 00-060 3004 54.6 98.8 00-090 3039 55.3 100.0 90-180 0000 0.0 000.0 00-180 3039 55.3 100.0

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 6515. 6821. 6766. 55 4728. 3371. 1327. 65 342. 473. 408. 75 64. 107. 193. 85 64. 128. 191.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 7018. 7568. 7701. 55 5677. 3652. 1095. 65 13. 460. 381. 75 21. 86. 193. 85 64. 128. 255.

Ordering Information Explanation of Catalog Number. Example: LCS6G20LW228120PG

W 2

LCLytecel 6" Continuous
Body StyleA =Air Return S =Static
Ceiling TypeG = 9/16" or
Louver FinishL =Low
Lamp Quantity(By others)
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog
Cells1 row of 20 cells
Length28 =T5 54 =T5HO (Nominal 48")

15/16"Grid T = Slot Grid

Iridescence Semi-specular P=Low

no, ie(GLR)

Ballast Type:

Standard Lytecel LC

Reflector:

For NYC Code – Local 3 Manufactured LN

Options/Accessories Access Plate: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP. Coupler/Clamp: (Set of 2) Required for beginning of rows. Order Catalog Number: LC85 CLAMP (for G or T type) End Trim: Required at beginning and end of rows. For every row order (2). Order Catalog Number: LC6 END TRIM. Electrical/Wiring Options: Consult factory. EM Pack or Dimming Ballast: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.

Specifications (continued) Air Handling–(LCA only) Side air passages for air return. Materials: Chassis parts are die-formed cold rolled steel. Louver: Pre-anodized aluminum (Coilzak® or equal). Finish: Louver—specular or semi-specular low iridescence pre-anodized reflector sheet. Reflector: White baked polyester enamel. Chassis exterior— black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org

Internal slow-blow fusing. Suffix: GMF. Chicago Plenum: Suffix: CP.

Specifications Performance: In an installation of 2 lamp 28W semi-specular luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .56 with a spacing to mounting ratio of 1.3 perpendicular to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probability) shall not be less than 87 either crosswise or lengthwise and the candela value between 55° and 90° in the 0° to 90° planes shall not exceed 2858. Candelas at Nadir (0°) not to exceed 1373.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2007 a Genlyte company Section 2/Folio G07-46
Show 8 more labels / short text on this page
Fixture · Number of · Lamp Fixture · Width · Louver Appearance · 2=2 Lamp · Iridescence Specular · W=White
情報源

参考資料・リンク

この取扱説明書で参照されているリンク(メーカー、サポート、ダウンロード等)。

Lightolier LCS6G20LW228について質問する

ユーザーまたはスタッフが通常1日以内に回答します。あなたの質問が次の人の助けにもなります。

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Lightolier LCS6G20LW228に関する質問はまだありません

最初の質問を投稿しましょう。他のユーザーや当チームが回答します。

原本

Lightolier LCS6G20LW228 取扱説明書(PDF)

2 ページ·138 KB·インテリア家具・調度品·PDF
上のページをクリックするとここに表示されます
ページ 1 / …
100%
ページを読み込み中…