Page 1 of 2 For Continuous Row Mounting – 6-1/2" wide, 12 Cell (1 Row) Parabolic Louver,

G
exposed T-grid ceiling.
exposed slot T-grid ceiling.




2" max.
2" max.
End Plate for beginning and end of row
exposed T-grid ceiling.


2" max.
2" x 2-1/2" Access Plate with (2) 7/8" K.O.s 2-5/32" (55mm)

Job Name:
Cat. No.:
Hold-down Clip Side Rail continuous row coupler locks fixtures together for a continuous line of light
Lamp(s):
Volts/Ballast:
without cell configuration interruption

Page 2 of 2 For Continuous Row Mounting – 6-1/2" wide, 12 Cell (1 Row) Parabolic Louver,
Photometry Model No. LCS8G12PR132120SO
LER = FP - 53.2 IW - 32 BF - 0.92 Comparative yearly lighting energy cost per 1000 lumens = $4.53

coefficients of utilization — zonal cavity method
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
S
R
Body Style:
N = NYC Code
Iridescence Specular L=Low
Length:
32=T8 (Nominal 48")
Ballast type:
DA=DALI digital addressable dimming.
Options/Accessories Access Plate: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP. Electrical/Wiring Options: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.
Specifications (continued) Finish: Louver—specular low iridescence pre-anodized reflector sheet. Reflector: Semi-Specular reflector sheet, 95% reflective. Chassis exterior— black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed.
Internal slow-blow fusing. Suffix: GMF. Chicago Plenum: Suffix: CP.
Specifications Performance: In an installation of 1 lamp 32W luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71 with a spacing to mounting ratio of 1.5 perpendicular to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probability) shall not be less than 95 either crosswise or lengthwise and the candela value between 55° and 90° in the 0° to 90° planes shall not exceed 844. Candelas at Nadir (0°) not to exceed 908. Materials: Chassis parts are die-formed cold rolled steel. Housing is with all edges turned-in for safe handling. Louver: Pre-anodized aluminum (Coilzak® or equal).