Page 1 of 2 Recessed Lens Fluorescent, Static or Air Return
6" Width X 48" Length, 1 or 2 Lamp T5

Static
Patent Pending
Mounting Methods Dimensions

exposed T-grid ceiling.
exposed slot T-grid ceiling.
T


2" max.
2" max.


2" max.
hold-down clips (1 at each end)

4.25" (108mm)
Job Name:
Cat. No.:
Lamp(s):
Shown in Armstrong TECH ceiling.
Volts/Ballast:

Page 2 of 2 Recessed Lens Fluorescent, Static or Air Return
6" Width X 48" Length, 1 or 2 Lamp T5
Model No. LIA6GPNXR228UNVPG LER = FP - 56.4 IW - 56.21 BF - 1.00 Comparative yearly lighting energy cost per
LER = FP - 62.5 IW - 31.99 BF - 1.00 Comparative yearly lighting energy cost per
CANDELA DISTRIBUTION
1000 lumens = $3.84 Report Number: G2008084 Catalog Number: LIA6GPNXR128UNVPG Lamp: F28 T5 Luminaire: 6" wide Troffer with PN lens. Ballast: B228PUNV-C Report is based on 2750 Lumens per lamp. Efficiency: 72.7% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.1 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 4.560

1000 lumens = $4.25 Report Number: G2008075 Catalog Number: LIA6GPNXR228UNVPG Lamp: (2) F28 T5 Luminaire: 6" wide Troffer with PN lens. Ballast: B228PUNV-C Report is based on 2750 Lumens per lamp. Efficiency: 57.6% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.1 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 4.560

0.0 45.0 90.0 FLUX
0 844 844 844
0 1342 1342 1342
5 831 837 840 80
5 1322 1331 1337 126
15 798 791 782 223
15 1270 1256 1240 354
25 737 702 675 325
25 1172 1114 1070 516
35 652 588 568 376
35 1038 929 901 596
45 548 474 438 371
45 871 751 698 589
55 424 340 292 309
55 676 539 455 488
65 286 194 146 201
65 458 305 225 317
75 139 66 66 91
75 225 100 104 145
85 21 21 18 24
85 35 32 30 37
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
90 3 7 8
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
90 4 11 13
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
1 80 77 74 72 70 68 69 67 66 2 73 67 63 64 60 57 61 58 56 3 67 60 54 56 52 48 55 51 48 4 62 53 47 51 46 42 49 45 41 5 57 48 42 46 40 36 44 40 36 6 53 43 37 41 36 32 40 35 32 7 49 39 33 38 32 29 37 32 28 8 46 36 30 35 29 26 34 29 26 9 43 33 27 32 27 23 31 26 23 10 40 31 25 30 25 21 29 24 21
ZONE LUMENS % LAMP % FIXT 00-030 627 22.8 31.4 00-040 1004 36.5 50.2 00-060 1683 61.2 84.2 00-090 2000 72.7 100.0 90-180 0000 0.0 000.0 00-180 2000 72.7 100.0
1 63 61 58 57 55 54 55 53 52 2 58 53 50 50 48 45 49 46 44 3 53 47 43 45 41 38 43 40 38 4 49 42 37 40 36 33 39 35 33 5 45 38 33 36 32 29 35 31 29 6 42 34 29 33 29 25 32 28 25 7 39 31 26 30 26 23 29 25 22 8 36 29 24 27 23 20 27 23 20 9 34 26 22 25 21 18 25 21 18 10 32 24 20 23 19 17 23 19 17
ZONE LUMENS % LAMP % FIXT 00-030 996 18.1 31.4 00-040 1593 29.0 50.3 00-060 2670 48.5 84.3 00-090 3168 57.6 100.0 90-180 0000 0.0 000.0 00-180 3168 57.6 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 5627. 4867. 4497. 55 5367. 4304. 3696. 65 4913. 3333. 2508. 75 3899. 1851. 1851. 85 1749. 1749. 1499.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 8943. 7711. 7167. 55 8557. 6823. 5759. 65 7868. 5240. 3865. 75 2912. 2805. 2917. 85 2916. 2666. 2499.
X R
UNV
Length:
15/16"Grid T = Slot Grid D = 9/16" Tegular
Acyrlic VA = .095 Virgin
28=T5 (Nominal 48")
1=1 Lamp 2=2 Lamps
Acyrlic KA = .156 Virgin
Ballast Type:
Options/Accessories Access Plate: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP. Electrical/Wiring Options: Consult factory. EM Pack or Dimming Ballast: Consult factory. Fusing: Internal fast-blow fusing. Suffix: A.
Finish: Reflector: 95% reflective Miro aluminum reflector.
Chassis exterior—black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow-blow fusing. Suffix: C. Chicago Plenum: Suffix: C.
Specifications Performance: In an installation of 1 lamp 28W luminaire in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77 with a spacing to mounting ratio of 1.1 perpendicular to the lamps. Air Handling- Side air slots for air return. Materials: Chassis parts are 20 gauge cold rolled steel.