Page 1 of 2 Recessed Lens Fluorescent, Static or Air Return
6" Width X 48" Length, 1 or 2 Lamp T8

Static
Patent Pending
Mounting Methods Dimensions

exposed T-grid ceiling.
exposed slot T-grid ceiling.


2" max.
2" max.


2" max.
hold-down clips (1 at each end)

4.25" (108mm)
Job Name:
Cat. No.:
Lamp(s):
Shown in Armstrong TECH ceiling.
Volts/Ballast:

Page 2 of 2 Recessed Lens Fluorescent, Static or Air Return
6" Width X 48" Length, 1 or 2 Lamp T8
Model No. LIA6GPNXR232UNVHI LER = FP - 52.1 IW - 52.9 BF - 0.88 Comparative yearly lighting energy cost per
LER = FP - 51.2 IW - 31.15 BF - 0.90 Comparative yearly lighting energy cost per
CANDELA DISTRIBUTION
1000 lumens = $4.68 Report Number: G2008095 Catalog Number: LIA6GPNXR132UNVHI Lamp: (1) F32 T8 Luminaire: 6" wide Troffer with PN lens. Ballast: ICN-1P32-SC Report is based on 2850 Lumens per lamp. Efficiency: 62.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.1 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 4.560

1000 lumens = $4.61 Report Number: G2008052 Catalog Number: LIA6GPNXR232UNVHI Lamp: (2) F32 T8 Luminaire: 6" wide Troffer with PN lens. Ballast: ICN-2P32-SC Report is based on 2850 Lumens per lamp. Efficiency: 54.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.1 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 46.800 4.560

0.0 45.0 90.0 FLUX
0 759 759 759
0 1326 1326 1326
5 749 749 756 71
5 1305 1314 1320 125
15 718 704 696 199
15 1252 1240 1227 350
25 663 624 597 289
25 1156 1102 1062 510
35 586 520 501 334
35 1022 923 894 591
45 491 419 388 329
45 857 746 691 584
55 380 300 256 273
55 664 531 453 482
65 257 170 127 177
65 448 300 221 311
75 127 55 58 81
75 220 98 102 142
85 20 18 16 20
85 34 33 27 36
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
90 2 6 7
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
90 4 10 134
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
1 68 66 63 62 60 58 59 58 56 2 63 58 54 54 51 49 52 50 48 3 57 51 46 48 45 41 47 43 41 4 53 46 40 43 39 36 42 38 35 5 49 41 36 39 35 31 38 34 31 6 45 37 32 35 31 28 34 30 27 7 42 34 28 32 25 25 31 27 24 8 39 31 26 30 25 22 29 25 22 9 36 28 23 27 23 20 27 23 20 10 34 26 21 25 21 18 25 21 18
ZONE LUMENS % LAMP % FIXT 00-030 560 19.6 31.5 00-040 893 31.3 50.4 00-060 1496 52.5 84.3 00-090 1774 62.2 100.0 90-180 0000 0.0 000.0 00-180 1774 62.2 100.0
1 60 58 56 54 53 51 52 51 50 2 55 51 48 48 45 43 47 44 42 3 51 45 41 43 39 37 41 38 36 4 47 40 36 38 35 32 37 34 31 5 43 36 31 34 31 28 33 30 27 6 40 33 28 31 27 24 30 27 24 7 37 30 25 28 25 22 28 24 21 8 34 27 23 26 22 19 25 22 19 9 32 25 21 24 20 18 24 20 17 10 30 23 19 21 19 16 22 18 16
ZONE LUMENS % LAMP % FIXT 00-030 985 17.3 31.5 00-040 1576 27.7 50.3 00-060 2642 46.4 84.4 00-090 3131 54.9 100.0 90-180 0000 0.0 000.0 00-180 3131 54.9 100.0
LUMINANCE DATA IN CANDELA/SQ. METER
AVERAGE AVERAGE AVERAGE AVERAGE
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 5042. 4302. 3984. 55 4810. 3797. 3241. 65 4415. 2921. 2182. 75 3563. 1543. 1627. 85 1666. 1499. 1333.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 8800. 7660. 7095. 55 8405. 6722. 5734. 65 7697. 5154. 3797. 75 6172. 2749. 2861. 85 2832. 2749. 2249.
X R
UNV HI
Length:
15/16"Grid T = Slot Grid D = 9/16" Tegular
Acyrlic VA = .095 Virgin
32=T8 (Nominal 48")
1=1 Lamp 2=2 Lamps
Acyrlic KA = .156 Virgin
Ballast Type:
LN
Options/Accessories Access Plate: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP. Electrical/Wiring Options: Consult factory. EM Pack or Dimming Ballast: Consult factory. Fusing: Internal fast-blow fusing. Suffix: A.
Finish: Reflector: 95% reflective Miro aluminum reflector.
Chassis exterior—black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow-blow fusing. Suffix: C. Chicago Plenum: Suffix: C.
Specifications Performance: In an installation of 1 lamp 32W luminaire in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .66 with a spacing to mounting ratio of 1.1 perpendicular to the lamps. Air Handling- Side air slots for air return. Materials: Chassis parts are 20 gauge cold rolled steel.