Page 1 of 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver, Air Return/Static, 1 Lamp T5, IES RP1 For VDT Areas



exposed T-grid ceiling.
exposed slot T-grid ceiling.


2" max.
2" max.


2" x 2-1/2" Access Plate with (2) 7/8" K.O.s

2" max.
Air Return Slots (LIA only)
hold-down clips (1 at each end)
48" (1220mm) 39-1/4" (997mm)

Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Shown in Armstrong TECH ceiling.

Page 2 of 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver, Air Return/Static, 1 Lamp T5, IES RP1 For VDT Areas
Model No. LIS6G20LW154120PG LER = FP - 40.3 IW - 59.0 BF - 1.0 Comparative yearly lighting energy cost per
Model No. LIS6G20PW154120PG LER = FP - 43.4 IW - 59.0 BF - 1.0 Comparative yearly lighting energy cost per
1000 lumens = $5.95 Report Number: G1206004 Catalog Number: LIS6G20LW154120PG Lamp: F54 T5HO Luminaire: 6" wide Troffer with semi- specular louver and white reflector. Ballast: Advance ICN-2S54 Report is based on 4400 Lumens per lamp. Efficiency: 54.9% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.6 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.943 5.816
1000 lumens = $5.53 Report Number: G1206005 Catalog Number: LIS6G20PW154120PG Lamps: F54 T5HO Luminaire: 6" wide Troffer with specular louver and white reflector. Ballast: Advance ICN-2S54 Report is based on 4400 Lumens per lamp. Efficiency: 58.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.6 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 47.943 5.816


0.0 45.0 90.0 FLUX
0 1040 1040 1040
0 1052 1052 1052
5 1059 1075 1113 102
5 1082 1101 1094 103
15 978 1069 1124 302
15 1029 1102 1130 306
25 900 1081 1412 514
25 927 1090 1491 532
35 792 1193 1432 711
35 829 1350 1617 782
45 630 856 443 523
45 668 965 431 568
55 372 220 110 227
55 446 217 95 244
65 20 30 21 29
65 1 30 18 20
75 3 4 6 5
75 1 3 7 4
85 1 1 2 2
85 1 2 3 2
90 0 1 1
90 0 1 1
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200
TYPICAL V.C.P.'s
TYPICAL V.C.P.'s
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
Mounting Height Lengthwise Crosswise Room Luminaires Luminaires Size 0 Deg Plane 90 Deg Plane 8.5 10 8.5 10 8.5 10 8.5 10 30x30 89 85 84 76 96 93 92 84 40x40 89 86 85 81 96 93 93 87 60x30 80 86 85 79 96 93 92 85 60x60 89 86 84 81 96 94 93 88 100x100 89 86 84 82 96 95 94 88
RC 80 50 30 RW 70 50 30 50 30 10 50 30 10
Mounting Height Lengthwise Crosswise Room Luminaires Luminaires Size 0 Deg Plane 90 Deg Plane 8.5 10 8.5 10 8.5 10 8.5 10 30x30 87 76 78 75 96 93 93 84 40x40 87 76 78 79 97 93 93 87 60x30 87 76 78 79 96 93 93 85 60x60 88 77 79 79 96 94 94 88 100x100 88 77 79 79 95 94 95 89
1 61 60 58 56 55 54 54 53 52 2 57 54 51 51 49 47 49 48 46 3 53 49 45 47 44 42 45 43 41 4 50 44 40 42 39 37 41 38 36 5 46 40 36 39 35 33 38 35 32 6 43 37 32 35 32 29 34 31 29 7 40 33 29 32 29 26 32 28 26 8 37 31 27 30 26 24 29 26 23 9 35 28 24 27 24 21 27 24 21 10 33 26 22 25 22 19 25 22 19
1 65 63 61 60 58 57 57 56 55 2 61 57 54 54 52 50 52 51 49 3 57 52 48 49 46 44 48 45 43 4 53 47 43 45 41 39 44 41 38 5 49 43 38 41 37 34 40 37 34 6 45 39 34 37 34 31 36 33 30 7 42 35 31 34 30 28 33 30 27 8 39 32 28 31 28 25 31 27 25 9 37 30 25 29 25 22 28 25 22 10 35 28 23 27 23 20 26 23 20
ZONAL LUMEN SUMMARY
LUMINANCE DATA IN CANDELA/SQ. METER
ZONAL LUMEN SUMMARY
AVERAGE AVERAGE AVERAGE AVERAGE
ZONE LUMENS % LAMP % FIXT 00-030 918 20.9 38.0 00-040 1629 37.0 67.5 00-060 2379 54.1 98.5 00-090 2414 54.9 100.0 90-180 0000 0.0 000.0 00-180 2414 54.9 100.0
ZONE LUMENS % LAMP % FIXT 00-030 942 21.4 36.8 00-040 1724 39.2 67.3 00-060 2536 57.6 99.0 00-090 2563 58.2 100.0 90-180 0000 0.0 000.0 00-180 2942 51.6 100.0
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4954. 6726. 3485. 55 3605. 2128. 1068. 65 264. 401. 278. 75 63. 84. 135. 85 41. 69. 124.
IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 5251. 7583. 3387. 55 4318. 2106. 923. 65 10. 397. 242. 75 14. 75. 159. 85 45. 103. 192.
W 1
15/16"Grid T = Slot Grid A = 9/16" Tegular
Iridescence Semi-specular P=Low
Grid D = 15/16" Tegular
Ballast Type:
Options/Accessories Access Plate: Top Wiring access plate is shipped with fixture as standard. When access plates are required in advance for wiring convenience, specify separately. Order Catalog Number: ACP5 CSP. Electrical/Wiring Options: Consult factory. EM Pack or Dimming Ballast: Consult factory. Fusing: Internal fast-blow fusing. Suffix: GLR.
Specifications (continued) Finish: Louver—specular or semi-specular low iridescence pre-anodized reflector sheet. Reflector: White baked polyester enamel reflector. Chassis exterior—black baked polyester enamel. Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. Labels: I.B.E.W./UL and ULc Listed. This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See: www.lamprecycle.org
Internal slow-blow fusing. Suffix: GMF. Chicago Plenum: Suffix: CP.
Specifications Performance: In an installation of 1 lamp 54W semi-specular luminaires in a room cavity ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .60 with a spacing to mounting ratio of 1.6 perpendicular to the lamps. To meet IES RP-1 for VDT areas the VCP (visual comfort probability) shall not be less than 89 either crosswise or lengthwise and the candela value between 55° and 90° in the 0° to 90° planes shall not exceed 3605. Candelas at Nadir (0°) not to exceed 1040. Air Handling-(LIA) side air passages for air return. Materials: Chassis parts are die-formed cold rolled steel. Louver: Pre-anodized aluminum (Coilzak® or equal).