Offices

3' 9' 15' 21' 27' 30' 27' 21' 15' 9' 3'
46 49 49 49 50 46 50 49 49 49 46
2-T8 Lamps/4' section Fixture Suspension: 18" Quantity: 5 Rows of 7 Fixtures Efficiency: 82.7% Room Size: 60'x60'x10' Reflectance: 80 Ceiling
61 65 66 66 66 64 66 66 66 65 61
63 68 69 69 70 67 70 69 69 68 63
50 Wall 20 Floor Light Loss Factor: 0.70 Lumens T8 Lamp: 2850 Ballast Factor: 0.77 Average Maint. fc: 63.7 Watts/Square Foot: 0.85
64 69 70 70 71 68 71 70 71 69 64
64 69 70 70 71 68 71 70 70 69 64
64 69 70 70 71 68 71 70 70 69 64
Average Maintained fc:
64 69 70 70 71 68 71 70 71 69 64
30" High Work Surface
63 68 69 69 70 67 70 69 69 68 63
56 59 60 60 61 59 61 60 60 59 56
46 49 49 49 50 48 50 49 49 49 46

3' 9' 15' 21' 27' 30' 27' 21' 15' 9' 3'
55 58 59 59 59 57 59 59 59 58 55
1-T5HO Lamp/4' section Fixture Suspension: 18" Quantity: 5 Rows of 7 Fixtures Efficiency: 85.9% Room Size: 60'x60'x10' Reflectance: 80 Ceiling
72 77 79 78 79 75 79 78 79 77 72
75 81 83 83 83 79 83 83 83 81 75
50 Wall 20 Floor Light Loss Factor: 0.93 Lumens T5 Lamp: 5000 Ballast Factor: 1.02 Average Maint. fc: 76.2 Watts/Square Foot: 1.24
76 82 84 84 85 80 85 84 84 82 76
76 82 84 84 84 80 84 84 84 82 76
76 82 84 84 84 80 84 84 84 92 76
Average Maintained fc:
76 82 84 84 85 80 85 84 84 82 76
30" High Work Surface
75 81 83 83 83 79 83 83 83 81 75
72 77 79 78 79 75 79 78 79 77 72
55 58 59 59 59 57 59 59 59 58 55

Offices

2' 4' 6' 6' 4' 2'
42 45 47 47 45 42 47 49 53 53 49 47
55 57 61 61 57 55
58 60 65 65 60 58
55 57 61 61 57 55
47 49 53 53 49 47 42 45 49 47 45 42
Average Maintained fc:
30" High Work Surface

3' 7' 11' 15' 11' 7' 3'
55 54 55
LL8MF8LX232O4 (8') 2-T8 Lamps/4' section Quantity: 3 Rows of 3-8' Fixtures
65 65 65 64 65 65 65
67 68 68 66 68 68 67
68 68 68 67 68 68 68
50 Wall 20 Floor Light Loss Factor: 0.70 Lumens T8 Lamp: 2850 Ballast Factor: 0.77 Average Maint. fc: 63.9
67 68 68 66 68 68 67
65 65 65 64 65 65 65
55 54 55