Page 1 of 2 2 Light T5 Per 4’ (Nominal) Section


2 = 2 Lamp T5 28 = 28 Watts 4 = 4 Foot Blank = Static 1 = 120 VAC Blank = No Options 54 = 54 Watts 8 = 8 Foot E = Emergency 2 = 277 VAC X4 = 4 Through Wires 12 = 12 Foot D = Dimming 3 = 347 VAC X5 = 5 Through Wires (54W only) (Static only)
Features 1. Housing: 18 gauge die-formed pierced steel. 1/4" Aluminum end caps with access for through wiring. No exposed fasteners or hardware. 2. Lamping: 2-T5, 28 or 54 watt fluorescent lamps per 4’ section. By others. 3. Reflector: Precision die-formed, high reflectivity, and low iridescent aluminum. 4. Diffuser: Opal acrylic.
Labels UL, cUL, and I.B.E.W.
Ordering Instructions Individual Fixtures: 1. Order number of MODULES required. 2. Order one END SET per MODULE.
Electrical Ballast is electronic, meeting A.N.S.I. starting, end of life protection, T.H.D., A sound rating, and end-of-life specifications. 3 Conductor 18 gauge wire. Color- coded quick connectors allow ease of connection for fixture modules. For special circuitry consult factory.
Continuous Rows: 1. Determine run length 2. Order the appropriate number of MODULES for the complete run. 3. Order one END SET for each run.
Dimming: Advance Mark X. Use Advance compatible 2 wire control (no extra lead required).
Emergency Battery Pack: 54 Watt: 390-700 Lumens @ 90 min.
28 Watt: 370-520 Lumens @ 90 min.
Finish Powder coated baked white enamel. Custom colors available, consult factory.
Mountings Luminaires joined at 1 3/4" wide channel only. Housings are not contiguous. There is a 1" separation between housings on 8’ and 12’ fixtures (see bottom view drawing above). When fixtures are joined there will be the same 1" separation between housings as on the 8’ and 12’ luminaires.

Options and Accessories Dual Switching: Order the DS option for separate row switching. DS option comes complete with the 4 through wire option.
4 and 5 Wire: Order X4 for EM Battery Pack. For non-standard dimming options; order X5 option for Osram or DALI 54 Watt dimming and ESI 28 & 54 Watt.
Digital Dimming: Order X4 option for Lutron HiLume or ECO-10 54 Watt dimming.
Consult Factory for any additional wiring conditions.

Page 2 of 2 2 Light T5 Per 4’ (Nominal) Section
COEFFICIENTS OF UTILIZATION
ZONE CANDLEPOWER DEG. 0 22 45 67 90 180 1672 175 1766 1760 1741 1711 1682 165 2143 2090 1940 1763 1623 155 2449 2388 2170 1794 1516 145 2720 2619 2275 1805 1352 135 2886 2739 2336 1738 1140 125 3077 2889 2305 1607 893 115 3004 2894 2293 1405 609 105 2025 2015 1845 1197 327 95 819 819 725 587 73 90 19 15 9 1 0 85 23 20 11 3 1 75 33 31 20 11 6 65 41 39 30 22 16 55 47 45 39 32 26 45 49 49 44 39 35 35 49 50 47 44 40 25 49 51 49 47 45 15 49 50 49 47 45 5 44 45 44 43 43 0 42
ZONAL LUMEN SUMMARY ZONE LUMENS % BARELAMP % LUMINAIRE 0 - 90 149 1.5 1.9 90 - 180 7774 77.7 98.1 0 - 180 7924 79.2 100.0
4'
88 " 96-1/2" (OAL)
8'
3.5"
68 " 144-1/2" (OAL) 68 "
12'
192-1/2" (OAL) 8" 88 " 88"
16'
240-1/2" (OAL)
20'
288-1/2" (OAL)
24'
Mounting Accessories